10
SECTION 6 -
OPERATING INSTRUCTIONS
The fryers are of single pan type.
G3840 - Manual control model.
G3840F - Manual control model with inbuilt filtration.
USE OF OILS/SHORTENING/SOLIDS
(COOKING MEDIUM)
As these are highly flammable when in their liquid state,
caution should always be taken when using cooking
medium.
Recommendation
PPE (Personal Protective Equipment) should be used
when cleaning or handling medium within this fryer.
Medium should not be overheated as this will increase
the risk of fire.
Note: Fryer is fitted with a thermal safety device. This will
stop heating of medium if it becomes overheated.
This appliance will always fail safe.
Note: NEVER leave a working unit unattended.
Medium must always be maintained within fry pot.
Cold Medium - when filling with cold medium (see Figure
5), DO NOT FILL MEDIUM PAST -MIN- LEVEL MARK
(Maximum cold fill mark) also, for Solid Medium -
See Section 10.
-MIN- Level Mark: Medium should NEVER be allowed to
drop below this mark. Should this occur, top up
immediately or switch fryer OFF.
Hot Medium and
Topping Up Medium
DO NOT FILL MEDIUM
PAST -MAX- LEVEL MARK
(Maximum Hot Fill Mark).
(See
Figure
5).
Figure 5
CAUTION: SUITABLE PROTECTIVE CLOTHING
MUST BE WORN when topping up whilst fat in fryer
is hot.
Medium and Foodstuffs
Food will increase in volume during cooking - follow these
rules:
NEVER ADD WATER TO FRYING MEDIUM AT ANY
TIME!
WARNING
No attempt must be made to operate this appliance
during a power supply failure.
Please ensure that any plastic coated items are removed
prior to use. Before operation, pan requires to be
washed out and thoroughly dried.
Discolouration of heated parts is caused by factory
testing to ensure unit is satisfactory. It will not affect
quality or performance.
A neon indicator is incorporated to indicate flame failure
when illuminated.
An electronic thermostat with temperature probe is fitted
to automatically control oil temperature. The burner is
protected by an electronic flame sensor device.
An additional temperature limit thermostat is also fitted,
independent of main thermostat.
Operating thermostat failure could allow oil temperature
to exceed legislated maximum safe temperature (230
⁰
C).
In such a condition, limit thermostat will activate and cut
power to controller. It will also stop flow of gas to burner.
For location of re-set limit thermostat, refer to Figure 3
(5).
Limit Thermostat Reset
a) Turn burner and temperature controls to OFF position.
b) Allow oil to cool below 180
⁰
C.
c) Remove protective cap from limit thermostat reset
button. Ths is located behind cabinet door at upper
RH, below fascia panel.
d) Reset red button on limit thermostat with a pen or
similar item.
e) Turn burner and temperature controls to ON position.
f) Reselect temperature.
g) If limit thermostat reactivates, an investigation to
determine the reason must be carried out by a
qualified technician.
6.1 APPLIANCE CONTROLS
Refer to Sections 2.4.1 and 2.4.2 for controls layout and
description.
6.2 LIGHTING and OPERATION
Safety Precautions
The installer must fit a gas shut-off valve in the gas pipe
that supplies the unit.