G3840/G3840F FRYERS

 

INSTALLATION, SERVICING 
and USER INSTRUCTIONS

 

 

 

These appliances must be installed and serviced by a qualified person as stipulated by the Gas Safety

 

(Installation & Use) Regulations.

 

IMPORTANT

 

The installer must ensure that the installation of the appliance is in conformity with these instructions 

and National Regulations in force at the time of installation. Particular attention MUST be paid to -

 

Gas  Safety  (Installation  &  Use)  Regulations  I.E.E.  Regulations  for  Electrical  Installations 

Health And Safety At Work etc. Act                        Electricity at Work Regulations

 

Local and National Building Regulations 

Fire Precautions Act

 

Detailed  recommendations  are  contained  in  DW172  Institute  of  Gas  Engineers  published 

documents : IGE/ UP/ 1, IGE/ UP/ 2IGE/ UP/ 4BS6173 and BS5440

 

These appliances have been CE-marked on the basis of compliance with the Gas Appliance Directive 

for the Countries, Gas Types and Pressures as stated on the data plate.

 

WARNING -

 

TO PREVENT SHOCKS, ALL APPLIANCES, GAS OR ELECTRIC, MUST BE EARTHED.

 

On  completion  of  the  installation,  these  instructions  should  be  left  with  the  Engineer-in-Charge  for 

reference during servicing. Further to this, the user instructions should be handed over to the user, 

having had a demonstration of the operation and cleaning of the appliance.

 

PREVENTATIVE MAINTENANCE CONTRACT

 

In  order  to  obtain  maximum  performance  from  this  unit  we  would  recommend  that  a  Maintenance 

Contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out 

adjustments  and  repairs.  A  quotation  will  be  given  upon  request  to  the  SERVICELINE  contact 

numbers below.

 

WEEE Directive Registration No. WEE/DC0059TT/PRO

 

At  end  of  unit  life,  dispose  of  appliance  and  any  replacement  parts  in  a  safe  manner, 

via a licenced waste handler. Units are designed to be dismantled easily and recycling of 

all material is encouraged whenever practicable.

 

 

This equipment is ONLY FOR PROFESSIONAL USE, and shall be operated by QUALIFIED persons. 

It  is  the  responsibility  of  the  supervisor  or  equivalent  to  ensure  that  users  wear  SUITABLE 

PROTECTIVE CLOTHING and to draw attention to the fact that some parts will, by necessity,  become 

VERY HOT and will cause burns if touched accidentally.

 

 
 

Falcon Foodservice Equipment

 

HEAD OFFICE AND WORKS

 

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.

 

SERVICELINE CONTACT

 

Phone: 01438 363 000 

Fax: 01438 369 900

 

T100806 Ref. 6

 

Содержание G3840

Страница 1: ...er in Charge for reference during servicing Further to this the user instructions should be handed over to the user having had a demonstration of the operation and cleaning of the appliance PREVENTATI...

Страница 2: ...clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unb...

Страница 3: ...learance of at least 150mm to rear between unit and any combustible wall Important If fryer is to be installed with other appliances then the instructions for every model should be consulted to determ...

Страница 4: ...ross 1 7 INJECTOR SIZES Natural Gas Burner Pilot 2 x 2 6mm Polidora G31 2 Propane Gas Burner Pilot 2 x 1 7mm Polidora G25 SECTION 2 ASSEMBLY and COMMISSIONING The gas supply piping and connection to a...

Страница 5: ...n thermostat demands heat i e oil temperature is more than 5 C below temperature setting Extinguishes when desired temperature is reached Figure 3 Additional Controls 3 Burner Lock Out Reset Switch Re...

Страница 6: ...Using The Controller Section 6 2 3 2 5 2 Checking Oil Filtration Pump To check operation of oil filtration pump refer to Section 7 Important After installation the responsible technician should check...

Страница 7: ...m both sides of valve c Disconnect pilot pipe d Remove screws holding valve to bracket e Replace in reverse order Check system for gas leaks f Reset burner pressure as detailed in Section 1 4 3 5 PILO...

Страница 8: ...ace in reverse order Note Check for oil leaks before replacing any panels 3 13 IGNITION CONTROL BOX a Remove rear compartment cover b Unplug valve and control plugs Remove ignition detector and earth...

Страница 9: ...SIONS 187 24 min 26 max Timer Pump Settings Set for 230V Operating thermostat probe Set to 0 8 8 3 6 Setto10minutes 10 Safety thermostat probe Operating and Safety Thermostat Wu Set to Wu 23 17 5 258...

Страница 10: ...r supply failure Please ensure that any plastic coated items are removed prior to use Before operation pan requires to be washed out and thoroughly dried Discolouration of heated parts is caused by fa...

Страница 11: ...oil temperature will then be governed by controller to desired set temperature selected by user on the control knob SECTION 7 CHANGING FILTERING THE OIL Warning After filtering wait 30 seconds before...

Страница 12: ...ll liquid has been drained from fry pot The following procedure should be undertaken AT LEAST DAILY IMPORTANT Disconnect electrical supply before any cleaning commences Warning Oil must be allowed to...

Страница 13: ...rature probe Ensure FAT MELT CYCLE is selected for this process Note Fry plate will lower slowly into fry pot as solid fat melts Warning If fry plate does not sit flat lift plate from centre slightly...

Страница 14: ...SECTION 11 WIRING DIAGRAM for G3840 14...

Страница 15: ...SECTION 11 WIRING DIAGRAM for G3840F 15...

Страница 16: ...CIRCUIT DIAGRAM for G3840 16...

Страница 17: ...CIRCUIT DIAGRAM for G3840F 17...

Отзывы: