3.2
Non-regenerative power supplies
The non-regenerative QC-PS-
power supplies are part
of the FAGOR
Q
uer
C
us-
P
ower
D
rive
S
ystem. They are
connected via the mains filter to the three-phase mains
with line voltages between 400 (1-10%) V AC and 480
(1+10%) V AC and line frequencies of between 50 (1-
4%) Hz and 60 (1+3.3%) Hz.
The QC-PS-025 power supply comes integrated with an
auxiliary power supply allowing for the system control
electronics to be supplied with +24 V DC.
The QC-PS-045 power supply does not come with any
auxiliary power supply and, therefore, it must ALWAYS
be installed with the QC-APS-15 external auxiliary power
supply to feed the system control electronics with +24 V
DC.
QC-PS-025
QC-PS-045
Status indicator LED's
Associated with the auxiliary power supply:
Associated with the main power supply:
Connecto Function
A19
L1’/T1, L2’/T2, L3’/T3 terminals
Three-phase power input to the main power supply
A20
L1, L2, L3, FE (
F
unctional
E
arth)
Three-phase power input to auxiliary power supply
A17
(+/-) DC BUS terminals under lid
A18
+24 V DC, 7 A electric power supply output
X14
Basic control signals
X15
External braking resistor(s)
Leds
color
Function
red amber green
D1
ON
x
x
Over-voltage in the 24 V power supply
D2
ON
x
x
Over-current in the 24 V power supply
D3
x
x
ON
In the presence of +24 V DC
Leds D4
D5
D6 Function
red amber green
i
I
OFF
OFF
No errors. No line voltage or
PS ENABLE not enabled
ii
OFF OFF
OFF
DC BUS loading in progress
iii
OFF OFF
ON
DC BUS ready
iv
OFF
ON
ON
Crowbar circuit activation
v
ON
OFF
ON
Error. Over-voltage at the DC BUS
vi
ON
OFF
I
Error. I² t Crowbar
vii
ON
ON
OFF
Error. Short-circuit at the Crowbar IGBT
viii
ON
ON
ON
Error. Over-temperature at the heatsink
ix
ON
ON
I
Error. Soft-Start
I
: blinking
WARNING.
The DC BUS discharge period may extend for up to
10 min after the equipment has been disconnected from the elec-
trical mains. For this reason, always ensure that there is no volt-
age in the DC BUS before handling the equipment.
X14
Characteristics
plate
A20
Version/model
label
D1|D2|D3
D4|D5|D6
RESET.
Initialization
button
Opening and
closing click cover
tool with bottom
pivot hinge
A17
A18
Tight-
ening
torque:
3 N·m
3xM5
ground
screws
A19
X15
S16.
external
braking
resistor
selectors
QC-PS-025
SIZE |1.
Width: 78 mm
Status indicator LED's
D1|D2|D3 LEDs. Not being used.
D4|D5|D6 LEDs. Associated with the main power supply.
Connecto Function
A19
L1’/T1, L2’/T2, L3’/T3 terminals
Three-phase power input to the main power supply
A17
(+/-) DC BUS terminals under lid
A18
+24 V DC 7 A electric power supply output
X14
Basic control signals
X15
External braking resistor(s)
Leds D4
D5
D6 Function
red amber green
i
I
OFF
OFF
No errors. No line voltage or
PS ENABLE not enabled
ii
OFF OFF
OFF
DC BUS loading in progress
iii
OFF OFF
ON
DC BUS ready
iv
OFF
ON
ON
Crowbar circuit activation
iv
ON
OFF
ON
Error. Over-voltage at the DC BUS
v
ON
OFF
I
Error. I² t Crowbar
vi
ON
ON
OFF
Error. Short-circuit at the Crowbar IGBT
vii
ON
ON
ON
Error. Over-temperature at the heatsink
viii
ON
ON
I
Error. Soft-Start
I
: blinking
WARNING.
The DC BUS discharge period may extend for up to
10 min after the equipment has been disconnected from the elec-
trical mains. For this reason, always ensure that there is no volt-
age in the DC BUS before handling the equipment.
X14
Characteristics
plate
Version/model
label
D1|D2|D3
not used
D4|D5|D6
RESET
button.
not used
A17
A18
Tightening
torque: 3 N·m
3x M5 screws
to connect
the PE
A19
X15
S16.
External
braking resistor
selectors
Opening and
closing click cover
tool with bottom
pivot hinge
QC-PS-045
SIZE |1.
Width: 78 mm