QCQR-14/36
Q
uer
C
us - Power Drive System.
Q
uick
R
eference. Ref.2003
Braking resistors
Used to dissipate any excess energy generated by the
DC power BUS during electric motor braking. They do
not need an external power supply.
Bus protection module
Install in QC-PDS systems having:
Synchronous spindle and only when required by the
application
.
Purpose. Protect the power semi-conductors (IGBTs)
of the drive that governs it to prevent damage to the
unit due to a very high voltages that may be
generated at the power bus when the braking energy
cannot be returned during braking and/or
QC-RPS-
-F
power supply when only the
controlled stop is to be ensured.
Purpose. To ensure a controlled stop of the motor due
to mains failure because the energy may be
dissipated while braking at the external Ballast
resistors installed in the QC-BPM-100 module. Not
installing this module will result in an uncontrolled
stop (by friction) in case of a voltage failure due to an
over-voltage error of the bus because there are no
resistors to dissipate the braking energy.
ER+TH-18/
1100
1800
2200
ER+TH-18/
1000+FAN
1500+FAN
2000+FAN
MANDATORY.
ALWAYS
install
an external braking
resistor. Select the resistance according to the dissipated
power based on the application. See table.
POWER
OHM
RMS POWER
RESISTANCE
QC-PS-025
QC-PS-045
18
950 W
ER-TH-18/1100
1.3 kW
ER-TH-18/1800
2.0 kW
ER-TH-18/2200
2.0 kW
ER-TH-18/1000+FAN
3.0 kW
ER-TH-18/1500+FAN
4.0 kW
ER-TH-18/2000+FAN
WARNING.
HEAT DANGER. DO NOT TOUCH
the surface of
these resistors. Remember that they can sometimes
exceed temperatures of 300 °C (572 °F). If it is installed
in an easily accessible location, precautions must be
taken to prevent unintentional contact. Also avoid heat
sensitive items (cables, etc.) from coming into contact
with the surface to avoid damaging or destroying these
elements and/or causing other more dangerous
situations.
ER+TH-18/1100
ER+TH-18/1800
ER+TH-18/2200
ER+TH-18/1000+FAN
ER+TH-18/1500+FAN
ER+TH-18/2000+FAN
Element to
connect with
the external
thermostat
Braking
resistor
connection
terminals
Braking
resistor
connection
terminals
Terminals for
connecting the
fan
Element to
connect with
the internal
thermostat
Connection terminals of the
internal thermostat.
Temperature sensor
Fan turning direction
QC-BPM-100
Equipment status LEDs
Connector
Function
X54
Basic control signal connection.
X56
External braking resistor connection.
A17
(+/-) DC BUS terminals
A18
+24 V DC electric power supply input
D57
FAULT
There is an error. Top LED red
BALLAST
Crowbar ON. Middle LED amber
READY
Unit ready. Bottom LED green
WARNING.
The DC BUS discharge period may extend for up to
10 min after the equipment has been disconnected from the elec-
trical mains. For this reason, always ensure that there is no volt-
age in the DC BUS before handling the equipment.
A18.
+24 V DC input
A17.
(+/-) DC BUS
QC-BPM-100
SIZE |0.
Width: 39 mm
X54
A17
A18
X56
PE
ground bolt, M5.
Tightening torque: 3 N·m
D1|D2|D3
RESET.
Initialization button for
t h e b u s p r o t e c t i o n
module
Version/model
label
Opening
and closing click
cover with bottom
pivot hinge
Characteristics
plate