71
Check that water enters in the machine (the doors must be closed).
When the boiler is full, water will start to come out through the rinse arms in order to fill the tank. If the door
is opened, the fill will stop. The rinse arms can be watched from the basket output of the appliance. Now it
is possible to activate the boiler heating via the
RINSE TEMP
(Fig. 12)
display, by pressing the ON/OFF
button of the display
for 3 seconds.
The
ECO
models do not have a boiler or boiler temperature display, therefore this does not apply. The
appliance will wait until the generator heats the water and then start to fill the tank. The instructions for the
start-up and use of the generator can be found in the generator instruction manual.
Once the tank is full, the appliance is operative and the heating starts, the following checks on the appliance
operation should be run:
•
Check that there are no water leaks in hoses, joints, etc.
•
Check that the tank levels are correct, below the overflow drainage.
•
Check that the curtains are correctly fitted (long curtains at the exits and short curtains in the
interior).
•
Check the correct operation of the detergent and rinse aid dispensers if installed.
•
Check the correct operation of the limit switch.
•
Check the correct operation of the emergency button.
•
Check that the appliance stops if the doors are opened.
•
Check that the temperatures are correct and the heating operates correctly.
•
Check that the wash cycle runs correctly and the different switches operate as required.
•
IMPORTANT!
Check the rotation of the drive geared motor: if it turns anticlockwise (see figure) the
safety lock does not operate. Therefore two of the connection phases of the drive motor should be
inverted in the electric panel, at the variator output.
DIRECTION
DIRECTION
ANTICLOCKWIS
E
CLOCKWIS
E
•
IMPORTANT!
Check that the dryer fan and the energy recovery fan rotate in the correct direction.
The dryer fan must be able to open the dryer air output cover and the energy recovery fan must
extract air. If both fans are not operating correctly, change the two phases of the electrical supply
cable.
4.13
Configuration of heating temperatures
The heating temperatures of the tank and the boiler can be configured using the digital thermometers,
WASH
TEMP
and
RINSE TEMP
(Fig. 12)
.
The preconfigured and nominal recommended temperatures are 85 ºC in the boiler and 62 ºC in the tank. If
these values are changes, adequate wash and/or rinse temperatures cannot be guaranteed.
If one of the digital thermometers is replaced, the nominal heating value must be configured.
The digital thermometers permit the configuration of temperatures within the following ranges:
RINSE TEMP
(Fig. 12)
Boiler: Temp range between 70 ºC and 85 ºC (Not available in ECO models).
WASH TEMP
(Fig. 12)
Tank: Temp range between 50 ºC and 65 ºC.
The procedure for changing the temperature parameters is as follows: