Rinse aid dispenser
The rinse aid inlet point is before the boiler water inlet, as shown
in the diagram.
The yellow cap (see image) must be removed. This will provide a
G 1/8" thread inlet where the rinse aid dispenser can be
connected.
In ECO models with hot water gas generator, the rinse aid
dispenser connection should be on the hot water generator itself
.
4.7.2
Feeder electrical connection
To complete the electrical connection of the detergent and rinse aid dispensers, remove the upper cover
protecting the electrical panel in order to access the connection strip for the dispensers/Limit switch
DE
(Fig. 3/Fig. 4
).
First set the mains switch
IG
(
Fig. 3/Fig.
4
) to
OFF
in order to remove the cover.
Next, remove the fastening bolts and
undo the cover.
IG, Fig. 3/Fig. 4
The rinse aid / detergent dispenser connection cables must be inserted through the two packing glands
DSR (Fig. 3/Fig. 4
) and connected to the dispenser/Limit switch connection strip
DE (Fig. 3/Fig. 4
). The
connection options are shown in
Fig.10
.
Fig. 13
Connection strip DE (Fig. 3/Fig. 4
).
Connection A
1 / 2
Tub fill and rinse active signal.
Connection B
1 / 3
Rinse active signal.
Connection C
1 / 4
Wash pump active signal.
Connection D
1 / 5
Electrical connection at 230V 1N~ (max.
1A) when the appliance is on.
Connection
Earth.
Connection E
6 / 5
Connection for extra emergency button.
Connection F
7 / 5
Limit switch connection.
On completion of the electrical connection, the cover of the electric panel must be replaced and secured.
4.8
Limit switch / Micro switch
The limit switch/micro switch is mounted at the end of the dishwasher output bench, where it is activated when
the basket reaches the end of the bench, and the machine operation is stopped. When the limit switch is
released on removing the baskets from the bench, the machine continues with the wash.
The electrical connection cables of the limit switch / micro switch must be inserted through the packing gland
DSR (Fig. 3/Fig. 4
) and connected to the terminal strip
DE (Fig. 3/Fig. 4
) on
connection
7 / 5 as for the
dispensers (see
Fig.10
.).
On completion of the electrical connection, the cover of the electric panel must be replaced and secured.