M. Motor
Function
motor identification. The limits of certain parameters
depend on the value of MP1 (for example: The upper limit of
SP10 is 110 % of the motor rated speed) like its default
parameter initialization through GC10. See command
GC10.
Function
Contains the torque constant of the synchronous motor; i.e.
themotor torque according to the rms current.
Valid values
0.00 ... 10.00 N·m/Arms
Default value
10.00 N·m/Arms.
Function
Contains the motor rated current. Manipulating MP3 may
affect parameter CP20 directly. See parameter CP20.
Valid values
0.00 ... 50.00 Arms. Depends on the motor connected.
Default value
10.00 Arms.
Function
Motor inertia.
Valid values
0.1 ... 1 000.0 kg·cm².
Default value
It depends on the motor connected.
MP1
*BASIC, RW
S00141
MotorType
MP2
*FAGOR, RW
S33968
MotorTorqueConstant
MP3
*FAGOR, RW
S00111
MotorContinuousStallCurrent
MP24 *FAGOR, RW
S33988
MotorMomentumOfInertia
NOTE.
This parameter will be set to its default value on
power-up whenever GP15 has been set to “1”.
Содержание ACSD series
Страница 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Страница 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Страница 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Страница 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...