![Fagor ACSD series Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/fagor/acsd-series/acsd-series_original-instructions-manual_538347034.webp)
ACSD-34/80
Digital Brushless
AC S
ervo
D
rive system - Ref.1609
About the connection
All the cables must be shielded, to reduce the interference on the control of the motor
due to the commutation of the PWM. The shield of the motor power cable must be
connected to the chassis screw at the bottom of the module and it, in turn, to mains
ground.
Electrical connections
Power connection. Mains - Drive
The power supply of “ACSD-xxL” units must be three-phase 220 V AC, except in
modules ACSD-05L and ACSD-10L that can also be single-phase if parameter GP16
has been properly set. ACSD-xxH units must always be powered with three-phase 400
V AC. Parameter GP16 is ignored for these models.
F. 18
Installation of ACSD modules.
NOTE.
Keep the signal cables away from the power cables.
INFORMATION.
If ACSD-20L and ACSD-30L (220 V AC) units were powered
with single-phase voltage, the software would limit the current to 10 A.
INFORMATION.
Do not power ACSD-xxH (400 V AC) units with single-phase
power voltage. The necessary bus voltage will never be reached.
NOTE.
The use of a transformer is not a must.
M6
M6
>50mm
>50mm
>10mm
>30mm
i
i
Содержание ACSD series
Страница 1: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives ACSD series Ref 1609 Original instructions ...
Страница 6: ...ACSD 6 80 Digital Brushless AC Servo Drive system Ref 1609 This page intentionally left blank ...
Страница 78: ...ACSD 78 80 Digital Brushless AC Servo Drive system Ref 1609 User notes ...
Страница 79: ...Digital Brushless AC Servo Drive system Ref 1609 ACSD 79 80 User notes ...