Working level
for normal daily operation
Switch to level
“I / O test parameters”
See section 8.1.
o parameters
Code: 10E5
Test relay outputs
Range
Default
Switched-on relays remain switched on until they are
reset manually.
o.1 Test relay 1
0 .. 1
0
o.2 Test relay 2
0 .. 1
0
o.3 Test relay 3
0 .. 1
0
o.4 Test relay 4
0 .. 1
0
o.5 Test relay 5
0 .. 1
0
o.6 Test relay 6
0 .. 1
0
o.7 Test relay 7
0 .. 1
0
o.8 Test relay 8
0 .. 1
0
o.9 Test relay 9
0 .. 1
0
o.10 Test relay 10
0 .. 1
0
o.11 Test relay 11
0 .. 1
0
o.12 Test relay 12
0 .. 1
0
o.14 Test of external relay 1
0 .. 1 0
o.15 Test of external relay 2
0 .. 1 0
o.16 Test of external relay 3
0 .. 1 0
o.17 Test of external relay 4
0 .. 1 0
o.18 Test of external relay 5
0 .. 1 0
0: Off
1: On
Meaning of the parameters
All inputs and outputs of the individual components can be tested in this parameter
level. For this purpose the corresponding relays are set to 'I' or '0'.
N : However, the two relays for the supply of acid and alkaline detergents are locked
B
against each other since never acid and alkaline detergents may
enter the tank
never
together!
This operating level is NOT reset automatically!
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters
code: C567
Service parameter
s
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5
8.11
“I / O test parameters” (o. parameters)
Level
8. Setting of parameters
Page 72
Содержание DARI-KOOL GALA-KOOL Pro