Page 48
Milk-volume-dependent cooling start delay
Default
Range
(Cooling power reduction in case of robot operation)
P50 Capacity of the milk pump in litres / minute
1,0 .. 99,9
30,0
Is needed to calculate the milk quantity in the tank
from the measured pump running time.
P51 Minimum milk quantity in the tank before
10 ..
50
300 litres
compressor starts for the first time
Prevents the freezing of small amounts of milk in the tank.
The compressor running time from this point is calculated
from [P52 and P53]
P52 Compr running time per X litres milk quantity
.
10 .. 00 se .
5
c
60
in connection with parameter [P53]
P53 Milk quantity in connection to compr running time
.
10 .. 99
litres
20
Example based on the default values:
per
liters of milk the compressor runs seconds =
20
60
70 litres of milk = 210 seconds compressor running time
P54 Minimum milk quantity in the tank until
10 ..
200
999 litres
switching to regular cooling operation
P55 Error message if no milk feed is detected for
0 .. 300 min.
60
X minutes from the last stop of the compressor
(a switchover to the regular cooling mode
does not take place)
Cooling start options
Range Default
P60 Auto start cooling mode after successful cleaning
0 .. 1
0
see also section .10.2
9
0: Auto start deactivated
1: Auto start activated (in case of successful cleaning)
8. Setting of parameters
8.3 Level “Extended cooling parameters” (P parameters)
For the parameterization
of the „milk-volume-
dependent cooling start
delay“, please see
parameter [P61]
ON
ON
Compressor
OFF
OFF
ON
OFF
OFF
> [P55] minutes = alarm
Cooling mode*
Cleaning*
* Settings in [P61]
6: START Cooling mode
7: START Cleaning mode