Page 5
Continuous stirring mode
From OFF mode, the agitator can be switched on by pressing a button and then
switched off again by pressing the OFF button.
Parameter [C25] can be used to set the time after which the agitator is to switch
off automatically.
The countdown can be interrupted at any time using the OFF button.
If [C25] is set to '0', the agitator will run continuously, but can be switched off at
any time using the OFF button.
Cleaning mode
The cleaning timer controls the water intake by time or level, as desired. All
running times (heater, pump, detergent injection) can be set separately. The
automatic switchover from acidic to alkaline detergent is also adjustable.
The
controls the different processes and times fully automati-
Gala-Kool Pro
cally.
Following a power failure the control unit will restart in the mode it was in
Robot interface
Depending on the parameter settings, the control unit includes a built-in robot inter-
face with the following functions:
- „Robot start / stop“ and
- “Butterfly valve open / closed“
These functions are controlled via the keypad.
Tank monitor function
During the entire cooling and cleaning process, the built-in tank monitor keeps check
on the correct operation of all components, in order to guarantee the perfect state of
the milk.
In particular, the following are monitored:
- minimum and maximum milk temperatures during cooling
- power failure (optionally power pack required!)
- agitator function (optionally agitator monitoring module required
- minimum and maximum temperatures during cleaning
- etc.
Any faults are indicated by two LEDs, and associated f
codes flash in the display.
ault
In the case of errors which may jeopardise the milk quality, the red LED “Don't add
milk” lights up.
1. Introduction
Содержание DARI-KOOL GALA-KOOL Pro
Страница 29: ...Page 29...
Страница 58: ...Page 58 8 Setting of parameters...