Working level
for normal daily operation
Fault messages tank monitor during cooling mode
Range
Default
Fault
h20 Target temperature 1 milking
F20
0 .. 30,0 °C
,0
st
6
(Starting from this point the monitoring of the
over / under temperature begins [h25] + [h29])
h21 Max. ime to reach target temperature
t
[h20]
0 .. 999 min.
0 = deactivated
180
h23 Max. vertemperature for a time ( rom cooling start)
o
f
F23
0 .. 30,0 °C
10,0
h24 Max. ime of overtemp
(from cooling start
t
erature
)
0 .. 999 min.
0 = deactivated
180
h25 Max. overtemperature with direct alarm triggering
F25
0 ..
°C
25,0
99,9
(from 1 milking)
st
h27 Min. ndertemperature for a time ( rom cooling start)
u
f
F27
0 .. 30,0 °C
2,0
h28 Max. ime of undertemp
(from cooling start)
t
erature
0 = deactivated
0 .. 999 min.
120
h29 Min. undertemperature with direct alarm triggering
0 .. 30,0 °C
0,5
F29
(from 1 milking)
st
Start the counter from cooling start
h31 Max. cooling interruption
0 = deactivated
F31
0 .. 999 min.
60
h32 Max. time in off mode after cleaning
F32
0 ..
min.
0 = deactivated
5000
600
h33 Min. cleaning cycle
F33
0 .. 250 h
78
0 = deactivated
h35 Detergent monitoring alkaline by float switch
F35
0 .. 2
0
0 = deactivated,
1 = high aktiv
2 = low aktiv
h36 Detergent monitoring acid by float switch
F36
0 .. 2
0
0 = deactivated
1 = high aktiv
2 = low aktiv
h38 Max. temperature difference monitoring sensor
1,0 .. 5,0
2,0
F38
during cooling mode
Switch to level
“General tank monitor parameters”
See section 8.1.
h parameters
Code: 4711
General cooling parameters
code: C212
Extended cooling parameters
code: D345
General cleaning parameters
code: B454
Extended cleaning parameters
code: C567
Service parameter
s
code: EA03
General tank monitor parameters
code: 4711
Extended tank monitor parameters
code: F94A
Alarm configuration
code: FFFF
Configuration
code: A384
I/O test parameters
code: 10E5
8.7 Level “General tank monitor parameters” (h parameters)
8. Setting of parameters
Page 60