manualshive.com logo in svg
background image

 

I

I

MPORTANT

MPORTANT

 

 

S

S

AFETY

AFETY

 

 

I

I

NFORMATION

NFORMATION

 

 

R

ESTRICTIONS

 & W

ARNINGS

Install the gate operator only if: 

1. The gate operator is appropriate for the construction of the gate and the usage Class of the application.  Make sure the 

gate is within the weight and length limitations specified for the operator. 

2. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 

(1.2m) above the ground to prevent a 2 1/4 inch (57.15mm) diameter sphere from passing through the openings 
anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. 

3. ALL EXPOSED PINCH POINTS ARE ELIMINATED OR GUARDED AND GUARDING IS SUPPLIED FOR EXPOSED 

ROLLERS.  DO NOT INSTALL THIS DEVICE UNLESS ALL ENTRAPMENT AND PINCH POINTS ARE ELIMINATED! 

4. The operator is intended for installation only on swing gates used to control vehicles.  Pedestrians must be provided with 

a separate access opening. 

5. The gate must be installed in a location so that enough clearance is provided between the gate and adjacent structures 

when opening and closing to reduce the risk of entrapment.  Gates should not open into public access areas. 

6. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.  DO 

NOT REDUCE REVERSING SENSITIVITY OR OVERTIGHTEN THE CLUTCH TO COMPENSATE FOR A DAMAGED 
GATE. 

7. Gate operator controls must be placed far enough from the gate to prevent the user from coming in contact with the gate 

while operating the controls.  All activating devices must be installed in a clear line-of-sight with the gate and its travel.  
Activating devices must be installed a minimum of 10 feet away from the gate.  Be sure to mount ALL operating devices 
clearly out of reach of through gate.  Controls intended to be used to reset an operator after two sequential activations of 
the entrapment protection device must be located in the line-of-sight of the gate.  Outdoor or easily accessible controls 
shall have a security feature to prevent unauthorized use. 

8. Warning signs must be permanently installed on both sides of the gate and must be fully visible to traffic and 

pedestrians. 

9. Install the gate system and gate in accordance with ASTM F220-02: Standard Specification for Automated Vehicular 

Gate Construction.  and with UL325: Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators and 
Systems 

Vehicular Gate Only 

Pedestrian

 

Acc

e

ss 

Fence 

The operator is intended for installation only 

on swing gates used for vehicular traffic.  

Pedestrians must be provided with a sepa-

rate access opening. 

NO ONE SHOULD CROSS THE PATH OF 

A MOVING GATE! 

Gate operator controls must be placed far 

enough from the gate to prevent the user 

from coming in contact with the gate while 

operating the controls.  All activating devices 

must be installed in a clear line-of-sight with 
the gate and its travel.  Be sure to mount all 
devices clearly out of reach of through gate. 

Fence 

Pilaster 

Fence 

Pilaster 

Provide spacing between the 

hinge, gate and pilaster to 

reduce the risk of entrapment for 

this area. 

Vehicular Gate Only 

Fence 

Pilas-

Mount hinges on 

the corner of 

pilasters to help 

prevent 

entrapment 

areas. 

Building 

Or 

Structure 

Or 

Fence 

Provide spacing 

between the 

hinge, gate and 

building to 

reduce the risk of 

entrapment in 

this area 

FSW900 Swing Gate Operator 

Содержание FSW900

Страница 1: ...nal Inc Headquarter East Coast Operations 5151 Sunbeam Road Suites 9 11 Jacksonville FL 32257 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Unit...

Страница 2: ...Reverse Sensitivity Adjustment 16 Reverse Sensitivity Shutdown 16 Close Time Delay Adjustment 17 DIP Switch Settings 17 ACCESSORY CONNECTIONS Accessory Wire Overview 18 Edge Sensor Connections 19 Pho...

Страница 3: ...nderstand the manufacturer can not be held responsible for damage or injury caused by improper erroneous or unreasonable use Failure to comply with these guidelines may create a dangerous situation an...

Страница 4: ...ust be installed in a clear line of sight with the gate and its travel Activating devices must be installed a minimum of 10 feet away from the gate Be sure to mount ALL operating devices clearly out o...

Страница 5: ...nce some devices only cover a select area For example a photo beam will not cover the full height of a gate fence area Refer to the diagram below Contact Sensors Edge Sensors Contact sensors generally...

Страница 6: ...ion of a wall or fence system that controls entrance and or egress by people or vehicles and completes the perimeter of a defined area VEHICULAR SWING GATE OPERATOR Or System A vehicular gate operator...

Страница 7: ...d gate hardware before installing the gate operator Add safety devices such as warning signs photo eyes and reverse edges to help prevent injuries or death Reduce all pinch points and protect all entr...

Страница 8: ...p cover 3 Lift the Release Handle 4 Remove the Alignment Pin 5 Move the gate to the desired location To reengage the gate operator 1 Make sure power is OFF 2 Manually move the gate to align the arm wi...

Страница 9: ...er Input 120 VAC Current 6A Cycles Hour 75 Travel Speed 90 In Approx 14 Seconds Maximum Gate Weight 800 lbs Maximum Gate Length 18 Feet Primary Entrapment Protection Inherent Current Sensor Secondary...

Страница 10: ...ete pad terminating directly under the operator Extend each conduit a minimum of 1 above the level of the concrete pad See the Conduit Location diagram below It is suggested to install a minimum of fo...

Страница 11: ...ion 1 Make sure the Arm Operator and gate are level with each other 2 A Measure 46 from gate hinge out on gate 3 B Measure 35 5 for Long Arm length 4 C Measure 29 5 for Short Arm length 5 Use the Gate...

Страница 12: ...lose Limit Cams to the approximate location 2 Turn the operator ON and give it an open command Let it run until it gets to the open position Give the operator a stop command when the gate reaches the...

Страница 13: ...ied from a circuit breaker panel and must have its own dedicated circuit breaker This supply must include a green ground conductor 3 Only use UL approved 14 AWG or larger 600 Volt Insulated Wire Use t...

Страница 14: ...r DO NOT USE THESE POWER OUTLETS FOR INSTALLATION OR SERVICE TOOLS Each plug supplies 110 VAC when AC power is active to the gate operator If AC is not available the power plugs will not supply power...

Страница 15: ...Master and which operator is the slave All external devices such as loop detectors and safety devices must be wired directly to the Master unit If one gate travels further than the other the gate that...

Страница 16: ...the gate to stop the gate while in travel The gate should stop and enter a Soft Shutdown upon striking the object 10 Repeat steps 2 6 until the correct sensitivity adjustment is found REVERSE SENSITI...

Страница 17: ...Sounds the alarm in shutdown applications 2 Anti Tailgate OFF Gate opens and closes normal ON Uses loops to control vehicles individually 3 Master Slave OFF Operator is set as a Master Primary ON Ope...

Страница 18: ...TIONS ACCESSORY WIRE OVERVIEW CLOSE Photo Cell OPEN Photo Cell O P E N E D G E C L O S E E D G E Radio Receiver OPEN CLOSE STOP FIRE LOCK Card Access 1 2 3 4 5 6 7 8 9 0 Key Box 1 2 3 4 5 6 7 8 9 0 Ph...

Страница 19: ...reverse the gate to the full closed position and enter a soft shutdown 3 NOTE If the gate was initially activated by a time clock with a contact closure across the Access Input this input will be ign...

Страница 20: ...l be located where a risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier and arm pinch point and entrapment areas Use caution when installing non conta...

Страница 21: ...to reset the operator settings Standard Reverse Input 1 Input is inactive when gate is closed or in the open cycle 2 When gate is open and Time Delay Close is ON an input will reset the Time Delay Cl...

Страница 22: ...ill remain open until an external input is made This prevents the Fire Input from closing the gate if in the open position Connecting Access Devices 1 Connect Fire Lock Control relays to FIRE and COMM...

Страница 23: ...the Radio Receiver uses 24VDC connect Radio Power to RADIO PWR 24VDC and RADIO PWR 24VDC Connecting FAAC XR2 Radio Receivers 1 Connect XR2 N O relay contacts to RADIO N O and RADIO COMMON 2 Connect X...

Страница 24: ...s are NO relay contacts Power must be applied externally Connecting External Alarm Warning Light 1 Connect Warning Light to the external power supply and Warning Com and N C outputs following the sche...

Страница 25: ...t should be 1 4 wide Cut diagonal corner slots to protect the wire insulation and keep the wire from changing directions quickly 3 Install loop wire Recommended Wire 14 AGW to 18 AGW Stranded XLPE Sta...

Страница 26: ...ket Make sure detector is secure and snapped in 4 Set different frequencies for each loop detector 5 Follow the directions provided with the PLD1500 for more detailed settings Ground Loop Wire Connect...

Страница 27: ...onnector While the operator is stopped wiggle the Limit Sensor connector If the limit or sensor wires blink on and off there is a loose connection 2 Start the operator watch Sensor 1 and Sensor 2 at s...

Страница 28: ...Controller PCB heat sink and faceplate assembly 3 GC 3000 Controller Assembly No PCB faceplate 4 MOTOR 0500 24 Motor 500W 24VDC 5 SW 0020 Gearbox 900 1 6 SW 0004 Weld arm connector with 12 bar 7 SW 00...

Страница 29: ...RE P PARTS ARTS Num FAAC p n Description 12 SW0003 Clutch assembly kit 13 SWITCH 0100 Limit switch 14 WIRE1101SK Sensors wire assembly with screws 15 AAA0450 Sensor cup assembly 16 AAA 0402 Motor Adap...

Страница 30: ...ability or reliability of the product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s instructions or has been operated unde...

Отзывы: