background image

 

L

L

IMITED

IMITED

 

 

W

W

ARRANTY

ARRANTY

 

 

FSW900 Swing Gate Operator 

30 

To the original purchaser only: 
 

FAAC International, Inc., warrants, for sixty 
(60) months from the date of invoice, this 
gate operator system manufactured and distributed by 
FAAC International, Inc. to be free from defects in material 
and workmanship under normal use and service for which it 
was intended provided it has been properly installed 
and operated. 
 
FAAC International, Inc.’s obligations under this 
warranty shall be limited to the repair or exchange 
of any part of parts manufactured by FAAC International, 
Inc. and distributed by FAAC International, Inc. 
Defective products must be returned to FAAC International, 
Inc., freight prepaid by purchaser, within the warranty 
period. Items returned will be repaired or replaced, at FAAC 
International, Inc.’s option, upon an examination of the 
product by FAAC International, Inc., which discloses, to 
the satisfaction of FAAC International, Inc., that the item is 
defective. FAAC International, Inc. will return the warranted 
item freight prepaid. The products manufactured by FAAC 
International, Inc. and distributed by FAAC International, Inc. 
are not warranted to meet the specific requirements, 
if any, of safety codes of any particular state, municipality, or 
other jurisdiction, and FAAC International, Inc. doesn’t  
assume any risk or liability whatsoever resulting from 
the use thereof, whether used singly or in combination with 
other machines or apparatus. 
 
Any products and parts not manufactured 
and distributed by FAAC International, Inc., will carry only 
the warranty, if any, of the manufacturer. This warranty shall 
not apply to any products or parts thereof which have been 
repaired or altered, without FAAC International, Inc.’s written 
consent, outside of FAAC International, Inc.’s workshop, or 
altered in any way so as, in the judgment of FAAC 
International, Inc., to affect adversely the stability or 
reliability of the product(s) or has been subject to misuse, 
negligence, or accident, or has not been operated in 
accordance with FAAC International, Inc.’s instructions. 
or has been operated under conditions more severe than, or 
otherwise exceeding, those set forth in the specifications for 
such product(s). FAAC International, Inc. shall not be liable 
for any loss or damage whatsoever resulting, directly or 
indirectly, from the use or loss of use of the product(s). 
Without limiting the foregoing, this exclusion from liability 
embraces a purchaser’s expenses for downtime or for 
making up downtime, damages for which the purchaser 
may be liable to other persons, damages to property, and 
injury to or death of any persons. 
 
 
 
 
 
 
 
 

 
 
FAAC International, Inc., does not assumes nor authorizes 
any person to assume for them any other liability in 
connection with the sale or use of the products of FAAC 
International, Inc. The warranty herein above set forth shall 
not be deemed to cover maintenance parts, including, but 
not limited to, hydraulic oil, filters, or the like. No agreement 
to replace or repair shall constitute an admission by 
FAAC International, Inc., of any legal responsibility to effect 
such replacement, to make such repair, or otherwise. This 
limited warranty extends only to wholesale customers who 
buy directly through FAAC International, Inc.’s normal 
distribution channels. FAAC International, Inc., does not 
warrant its products to end consumers. 
 
Consumers must inquire from their selling dealer 
as to the nature and extent of that dealer’s warranty, if any. 
This warranty is expressly in lieu of all other warranties 
expressed or implied including the warranties of 
merchantability and fitness for use. This warranty shall not 
apply to products or any part thereof which have been 
subject to accident, negligence, alteration, abuse, or misuse 
or if damage was due to improper installation or use of 
improper power source, or if damage was caused by fire, 
flood, lightning, electrical power surge, explosion, wind 
storm, hail, aircraft or vehicles, vandalism, riot or civil 
commotion, or acts of God. 

Содержание FSW900

Страница 1: ...nal Inc Headquarter East Coast Operations 5151 Sunbeam Road Suites 9 11 Jacksonville FL 32257 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Unit...

Страница 2: ...Reverse Sensitivity Adjustment 16 Reverse Sensitivity Shutdown 16 Close Time Delay Adjustment 17 DIP Switch Settings 17 ACCESSORY CONNECTIONS Accessory Wire Overview 18 Edge Sensor Connections 19 Pho...

Страница 3: ...nderstand the manufacturer can not be held responsible for damage or injury caused by improper erroneous or unreasonable use Failure to comply with these guidelines may create a dangerous situation an...

Страница 4: ...ust be installed in a clear line of sight with the gate and its travel Activating devices must be installed a minimum of 10 feet away from the gate Be sure to mount ALL operating devices clearly out o...

Страница 5: ...nce some devices only cover a select area For example a photo beam will not cover the full height of a gate fence area Refer to the diagram below Contact Sensors Edge Sensors Contact sensors generally...

Страница 6: ...ion of a wall or fence system that controls entrance and or egress by people or vehicles and completes the perimeter of a defined area VEHICULAR SWING GATE OPERATOR Or System A vehicular gate operator...

Страница 7: ...d gate hardware before installing the gate operator Add safety devices such as warning signs photo eyes and reverse edges to help prevent injuries or death Reduce all pinch points and protect all entr...

Страница 8: ...p cover 3 Lift the Release Handle 4 Remove the Alignment Pin 5 Move the gate to the desired location To reengage the gate operator 1 Make sure power is OFF 2 Manually move the gate to align the arm wi...

Страница 9: ...er Input 120 VAC Current 6A Cycles Hour 75 Travel Speed 90 In Approx 14 Seconds Maximum Gate Weight 800 lbs Maximum Gate Length 18 Feet Primary Entrapment Protection Inherent Current Sensor Secondary...

Страница 10: ...ete pad terminating directly under the operator Extend each conduit a minimum of 1 above the level of the concrete pad See the Conduit Location diagram below It is suggested to install a minimum of fo...

Страница 11: ...ion 1 Make sure the Arm Operator and gate are level with each other 2 A Measure 46 from gate hinge out on gate 3 B Measure 35 5 for Long Arm length 4 C Measure 29 5 for Short Arm length 5 Use the Gate...

Страница 12: ...lose Limit Cams to the approximate location 2 Turn the operator ON and give it an open command Let it run until it gets to the open position Give the operator a stop command when the gate reaches the...

Страница 13: ...ied from a circuit breaker panel and must have its own dedicated circuit breaker This supply must include a green ground conductor 3 Only use UL approved 14 AWG or larger 600 Volt Insulated Wire Use t...

Страница 14: ...r DO NOT USE THESE POWER OUTLETS FOR INSTALLATION OR SERVICE TOOLS Each plug supplies 110 VAC when AC power is active to the gate operator If AC is not available the power plugs will not supply power...

Страница 15: ...Master and which operator is the slave All external devices such as loop detectors and safety devices must be wired directly to the Master unit If one gate travels further than the other the gate that...

Страница 16: ...the gate to stop the gate while in travel The gate should stop and enter a Soft Shutdown upon striking the object 10 Repeat steps 2 6 until the correct sensitivity adjustment is found REVERSE SENSITI...

Страница 17: ...Sounds the alarm in shutdown applications 2 Anti Tailgate OFF Gate opens and closes normal ON Uses loops to control vehicles individually 3 Master Slave OFF Operator is set as a Master Primary ON Ope...

Страница 18: ...TIONS ACCESSORY WIRE OVERVIEW CLOSE Photo Cell OPEN Photo Cell O P E N E D G E C L O S E E D G E Radio Receiver OPEN CLOSE STOP FIRE LOCK Card Access 1 2 3 4 5 6 7 8 9 0 Key Box 1 2 3 4 5 6 7 8 9 0 Ph...

Страница 19: ...reverse the gate to the full closed position and enter a soft shutdown 3 NOTE If the gate was initially activated by a time clock with a contact closure across the Access Input this input will be ign...

Страница 20: ...l be located where a risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier and arm pinch point and entrapment areas Use caution when installing non conta...

Страница 21: ...to reset the operator settings Standard Reverse Input 1 Input is inactive when gate is closed or in the open cycle 2 When gate is open and Time Delay Close is ON an input will reset the Time Delay Cl...

Страница 22: ...ill remain open until an external input is made This prevents the Fire Input from closing the gate if in the open position Connecting Access Devices 1 Connect Fire Lock Control relays to FIRE and COMM...

Страница 23: ...the Radio Receiver uses 24VDC connect Radio Power to RADIO PWR 24VDC and RADIO PWR 24VDC Connecting FAAC XR2 Radio Receivers 1 Connect XR2 N O relay contacts to RADIO N O and RADIO COMMON 2 Connect X...

Страница 24: ...s are NO relay contacts Power must be applied externally Connecting External Alarm Warning Light 1 Connect Warning Light to the external power supply and Warning Com and N C outputs following the sche...

Страница 25: ...t should be 1 4 wide Cut diagonal corner slots to protect the wire insulation and keep the wire from changing directions quickly 3 Install loop wire Recommended Wire 14 AGW to 18 AGW Stranded XLPE Sta...

Страница 26: ...ket Make sure detector is secure and snapped in 4 Set different frequencies for each loop detector 5 Follow the directions provided with the PLD1500 for more detailed settings Ground Loop Wire Connect...

Страница 27: ...onnector While the operator is stopped wiggle the Limit Sensor connector If the limit or sensor wires blink on and off there is a loose connection 2 Start the operator watch Sensor 1 and Sensor 2 at s...

Страница 28: ...Controller PCB heat sink and faceplate assembly 3 GC 3000 Controller Assembly No PCB faceplate 4 MOTOR 0500 24 Motor 500W 24VDC 5 SW 0020 Gearbox 900 1 6 SW 0004 Weld arm connector with 12 bar 7 SW 00...

Страница 29: ...RE P PARTS ARTS Num FAAC p n Description 12 SW0003 Clutch assembly kit 13 SWITCH 0100 Limit switch 14 WIRE1101SK Sensors wire assembly with screws 15 AAA0450 Sensor cup assembly 16 AAA 0402 Motor Adap...

Страница 30: ...ability or reliability of the product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s instructions or has been operated unde...

Отзывы: