D600 AUTOMATED SYSTEM 

RE-LOCK

RELEASE

Fig.2

  

 

User’s 

guide

Read the instructions carefully before using the product and store them for future use.

GENERAL SAFETY REGULATIONS

If correctly installed and used, the D600 automated system will ensure a high degree of safety.

Some simple rules on behaviour can prevent accidental trouble:

- Do not, under any circumstances, stand under the door.

- Do not allow persons, animals or things to stay near the automated systems, especially while they are 

operating.

- Transit must occur while the door is fully open and with the automated system stopped. Keep the door 

under control during the entire movement and prevent other people accessing the area involved. 

- Keep remote-controls, or other pulse generators that could open the door, well away from children.

IMPORTANT! DANGER OF CRUSHING.

- Once a month: check if the anti-crushing system is able to detect the presence of a 50 mm high
  obstacle laid on the ground.
- Do not allow children to play with the automated system.
- Do not willingly obstruct door movement.
- Prevent any branches or shrubs from interfering with door movement.
- Keep the indicator-lights efficient and easy to see.
- Do not attempt to activate the door by hand unless you have released it.

- In the event of malfunctions, release the door to allow access and wait for qualified technical personnel to do the necessary work.

- When you have set manual operation mode, cut power to the system before restoring normal operation.

- Do not in any way modify the components of the automated system.

- Do not attempt any kind of repair or direct action whatever and contact qualified FAAC personnel only.
- At least every six months: arrange a check by qualified personnel of the automated system and the safety devices. 

system fully re-opens the door. If the automated system operates in automatic logic, the door re-closes 

after the pause time, otherwise, a new pulse has to be given to command closure. If an obstacle is 

detected during the opening manoeuvre, this will stop motion (e.g. thus preventing things and people 

from being lifted). To restore normal operation, give a new opening pulse.

If, during closure, an obstacle is detected in the same position more than three consecutive times, the 

automated system considers this distance as the new closing contact point and goes into closed status. 

To restore the correct positions, remove the obstacle and command a new cycle: at the next closure, 

the automated system will advance at low speed until it detects the closing contact point.

The door is normally closed; when the control unit receives an opening command by radio control, 

or from another type of pulse generator (Fig. 1), it activates the electric motor which, by means of a 

transmission chain or belt, pulls the door open to allow access.

- If the automatic mode was set, the door closes automatically after pause time has elapsed. An 

  opening pulse given during the opening stage has no effect.

- If the semi-automatic mode was set, a second pulse must be sent to close the leaf again. 

- An opening pulse supplied during opening, stops movement. An opening pulse given during re-closing,

  always causes movement to be reversed.

- A stop pulse (if specified) always stops movement.

For details of door activity during the different logics, consult the installation engineer.

Accessories (photocells) may be present in automated systems, that prevent the door from closing when 

there is an obstacle in the area they control.

Emergency manual opening is possible by using the release system.

The indicator-light (if supplied) indicates the current door movement.

The courtesy light is activated when the motor starts and continues for about 2 minutes after it turns off. 

If the courtesy light flashes, this means that automated system is in shut-down status due to a fault, and 

qualified personnel must be called in to repair.

MANUAL OPERATION

The D600 operator is equipped with an emergency release system activated from the inside – however, 

a lock can be fitted on request, for activating the release from the outside too.

If the door has to be moved manually due to a power cut or fault of the automated system, use the 

release device as follows:

- Turn off electric power to the system.

- Release the operator, by pulling the release handle downward (Fig. 2 ref. A).

Attention: make sure that there are no persons, animals or objects in the door movement area during 

the release manoeuvre.

RESTORING AUTOMATIC OPERATION MODE

- Relock the automated system by pulling the handle horizontally (Fig. 2 ref. B) and make sure that, when 

you release it, the “LOCK” window under the carriage is red, to confirm correct resetting.

- Move the door until you find the hook-on point.

- Power up the system.

MAINTENANCE

The D600 automated system does not require any periodic replacement of parts.

COURTESY LIGHT REPLACEMENT

To replace the lamp, grip the ceiling light with one hand and pull downward, as shown in Fig. 3.

Unscrew the lamp (type E27 - 230 Vac - max 40 W) and re-position the ceiling light.

DESCRIPTION

The D600 automated system is ideal to automate balanced sectional doors of single garages for residential use.

The automated systems consist of an electro-mechanical operator, electronic control unit and courtesy light built into a single unit.

The system is non-reversing and, therefore, the door locks mechanically when the motor is not operating and, consequently, no lock is necessary; 

a manual release makes it possible to move the door in case of a power cut or fault.

The automated system has an electronic obstacle detection system. If an obstacle is detected during the closing manoeuvre, the automated 

Fig.3

Fig.1

Содержание E600

Страница 1: ...00 board components p 10 8 3 Terminal boards and connectors p 10 8 4 DS1 Programming dip switches p 10 8 5 Operating logics p 10 9 COURTESY LIGHT p 11 10 CONNECTIONS p 11 11 PROGRAMMING p 12 11 1 Sett...

Страница 2: ...cm install the external control devices at a height of not below 150cm clear of the door movement area but in a position enabling visual control of the area When you have finished installing we advise...

Страница 3: ...ing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at poi...

Страница 4: ...access Do not use them for any other purpose 1 DIMENSIONS 2 TECHNICAL SPECIFICATIONS AUTOMATED SYSTEM D600 3 ANCILLARY ELECTRICAL EQUIPMENT Prepare the electric system in keeping with the instructions...

Страница 5: ...oducts but do not use grease and in any event follow the manufacturer s instructions Check correct balance and if the opening mechanical stops have been installed Remove the door s existing closing me...

Страница 6: ...g guide until it is near the front terminal the one opposite the drive coupling 3 Assemble the front fitting Fig 7 ref B to the transmission unit Fig 7 ref A 4 Apply slight tension to the chain tighte...

Страница 7: ...corresponding to the maximum height reached by the door during movement see Fig 4 3 Position the securing bracket of the front fitting so that the lower edge is at least 5 mm above the intersection po...

Страница 8: ...5 Mark drill and secure the fitting to the door using the screws ref Fig 17 NOT supplied Fig 14 Fig 15 Fig 18 Fig 17 Fig 16 8 Lift the sliding guide until the rear fitting is at the same level as the...

Страница 9: ...off the ground and cut off the excess section of rope 2 Make a knot at the end of the rope and assemble the release handle Fig 22 3 Pull the release handle down and check if the door can be moved man...

Страница 10: ...lse Stop Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effec...

Страница 11: ...27 If the STOP input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at...

Страница 12: ...However in automatic mode the unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fa...

Страница 13: ...establishes the deceleration points Pause time is fixed at 3 minutes MANUAL LEARNING WITH LOGIC A AUTOMATIC Hold down the SETUP push button until the SET UP LED goes on about 5 seconds The SET UP LED...

Страница 14: ...ref 5 The relevant LED starts to flash slowly for 5 sec 6 Within these 5 sec while the radio control LED is still flashing press and hold down the required push button on the radio control the radio c...

Страница 15: ...ush button flashes for the first 5 sec and then flashes more quickly for the next 5 sec 3 Both LEDs light up on steady beam for 2 sec and then go OFF 4 Release the pressed push button when both LEDs l...

Страница 16: ...ntly separating it from the plastic housing Unscrew the 4 screws in the 4 corners of the plastic housing Separate it from the base House the control unit as shown in Fig 36 First hook on the two faste...

Страница 17: ...before the manoeuvre is started Learning is not finished correctly and the SET UP LED flashes to signal a fault The automated system frequently reverses motion during the opening and or closing manoeu...

Страница 18: ...ns of a transmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the openin...

Страница 19: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Страница 20: ...D600 D600...

Страница 21: ......

Страница 22: ...orre dare un nuovo impulso di apertura Se viene rilevato un ostacolo in chiusura nella stessa posizione per tre volte consecutive l automazione assume tale quota come nuova battuta di chiusura e si po...

Страница 23: ...oppia fotocellule 2 Dispositivo di comando 1 Dispositivo di comando 2 Radiocomando Lampeggiante Nr Data Descrizione intervento Firme 1 Tecnico Cliente 2 Tecnico Cliente 3 Tecnico Cliente 4 Tecnico Cli...

Страница 24: ...ns of a transmission chain or belt pulls the door open to allow access If the automatic mode was set the door closes automatically after pause time has elapsed An opening pulse given during the openin...

Страница 25: ...chnician Customer 9 Technician Customer 10 Technician Customer Installer Customer Type of system Serial No Installation date Start up PART MODEL SERIAL NUMBER Operator Safety device 1 Safety device 2...

Страница 26: ...e moteur lectrique qui par l interm diaire de la transmission cha ne ou courroie entra ne la porte en position d ouverture et permet l acc s Si l on a s lectionn le fonctionnement automatique la porte...

Страница 27: ...nicien Client Installateur Client Type d installation N de s rie Date d installation Activation COMPOSANT MOD LE N DE SERIE Op rateur Dispositif de s curit 1 Dispositif de s curit 2 Paire de photocell...

Страница 28: ...1 wird der Elektromotor in Betrieb gesetzt der das Tor ber einen Ketten oder Riemenantrieb ffnet und Zugang Zufahrt erm glicht Wenn der Automatikbetrieb eingestellt wurde schlie t sich das Tor selbstt...

Страница 29: ...hniker Kunde 10 Techniker Kunde Monteur Kunde Art der Anlage Seriennummer Installationsdatum Inbetriebnahme BAUTEIL MODELL SERIENNUMMER Antrieb Sicherheitsvorrichtung 1 Sicherheitsvorrichtung 2 Fotoze...

Страница 30: ...impulso para obtener el cierre Un impulso de apertura durante la fase de apertura detiene el movimiento Un impulso de apertura durante la fase de cierre causa siempre la inversi n del movimiento Un i...

Страница 31: ...e 10 T cnico Cliente Instalador Cliente Tipo de equipo N de serie Fecha de instalaci n Activaci n COMPONENTE MODELO N DE SERIE Operador Dispositivo de seguridad 1 Dispositivo de seguridad 2 Par de fot...

Страница 32: ...ekt en toegang mogelijk maakt Als de automatische werking is ingesteld sluit de deur vervolgens uit zichzelf na de pauzetijd Als tijdens de openingsfase een openingsimpuls wordt gegeven heeft dit geen...

Страница 33: ...0 Technicus Klant Installateur Klant Type installatie Serienummer Datum installatie Activering ONDERDEEL MODEL SERIENUMMER Aandrijving Veiligheidsvoorziening 1 Veiligheidsvoorziening 2 Paar fotocellen...

Страница 34: ......

Страница 35: ...n in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassung der...

Отзывы: