C850
17
532015 - Rev.B
RP / RP2
E850
E850
J4
T
ranslation of the original instructions
ENGLISH
After positioning the BUS-technology photocells, proceed with
selecting the address for each pair using various combinations of
the DIP-SWITCHES located on each photocell.
Set the SAME chosen DIP-SWITCH ADDRESS on both
the transmitter and receiver of the same pair.
Ensure that two or more pairs of photocells do not
have the same address.
If no BUS accessories are used, leave terminals 18 and
19 free.
The following table describes how to set the dip-switches located
inside the transmitter and receiver of the BUS photocells.
Table - Addressing BUS photocell PAIRS
To allow operation of the installed BUS acces-
sories, store them on the board, as described
in paragraph 11.5.3.
11.4.4 TERMINAL BOARD J2, FLASHING LAMP (FIG.28)
LAMP (LAMP-COM):
Flashing lamp output.
11.4.5 TERMINAL BOARD J9 - POWER SUPPLY (FIG. 34)
PE:
Earth connection
N:
230 V~ or 115 V~ Power supply (Neutral)
L:
230 V~ or 115 V~ Power supply (Line)
For correct operation, you must connect the
board to the system’s earth conductor. Ensu-
re that a suitable differential magnetothermic
switch has been installed upstream.
11.4.6 Connectors J3, J5 - rapid connection opening and closing limit switches
(FIG.28)
Rapid connector for connecting the opening (J3) and closing (J5)
limit switches.
11.4.7 FREQUENCY SELECTOR DS1 (FIG. 27)
DIP-SWITCH used to set the HIGH or LOW work frequency of the
vehicle detection loops. See section 11.5.5.
11.4.8 CONNECTOR J4 - MINIDEC, DECODER AND RP CONNECTOR
Used for the rapid connection of the Minidec, Decoder and RP /
RP2 Receivers.
If a 2-channel receiver is used, like the RP2, it will be possible to
directly command automated system OPEN and CLOSE from a
2-channel radio control.
If a 1-channel receiver is used, like the RP, it will only be possible
to command OPEN.
Connect the accessory with the components side facing inside
the board.
Boards should be connected or disconnected
ONLY after having cut off electrical power.
11.4.9 REVERSING GATE OPENING CONNECTIONS FROM
Fig. 35
Example of radio accessory connection
Fig. 34
Dip1
Dip2
Dip3
Dip4
Ref.
Type
ON
OFF
OFF
OFF
B-C
OPENING
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
D
CLOSING
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
A
OPENING and
CLOSING
OFF
ON
OFF
ON
ON
ON
ON
ON
/
OPEN
PULSE
TX
DIP-SWITCH
RX
DIP-SWITCH
SAME
ADDRESS