5.2 WALLING IN THE FOUNDATION PLATE
1. Assemble the foundation plate as shown in Fig. 4.
2. The foundation plate must be positioned as shown in Fig. 5 (right-
hand closing) or Fig. 6 (left-hand closing) to guarantee the
correct meshing between the pinion and the rack.
3. Set the foundation plinth as shown in Fig. 7 and wall in the foundation plate using one or more sheaths for running the electrical cables
through the hole in the foundation plate.
Use a level to ensure that the plate is perfectly horizontal.
4. Wait for the cement to set.
5. Prepare the electrical cables for connecting the accessories and the electrical power, as shown in Fig. 3.
To facilitate connection to the control unit, pull out a stretch of cable measuring at least 1.5 m from the hole on
the plate.