C850 

25 

532015 - Rev.B

T

ranslation of the original instructions

ENGLISH

Display

 Funzione

Impostazione

13

When this function is activated, the 

CLOSE command

 during opening stops operation, 

otherwise the 

CLOSE command 

commands immediate reverse or when opening is 

completed (see also parameter 

14

)

Y

 = CLOSE stops

no

 = CLOSE reverses

14

When this function is activated and if the parameter 

13

 is “no”, the 

CLOSE command

 

commands immediate closing at the end of the opening cycle (stores CLOSE). If the 
parameters 

13

 and 

14

 are “no”, CLOSE commands immediate closing.

Y

 = closes at the end of opening

no

 = inmediate closure

15

When this function is activated, with the system stopped by a STOP 

another OPEN 

command

 moves in the opposite direction. If the parameter 

15

 is “no”, it always closes.

Y

 = moves in the opposite direction

no

 = always closes 

16

When this function is activated, during closing, the 

CLOSING SAFETY DEVICES

 stop and 

allow motion to resume when they are no longer engaged, otherwise they immediately 
reverse opening.

Y

 = closes when no longer engaged

no

 = immediate reversal

17

When this function is activated, the 

CLOSING SAFETY DEVICES

 command closing when 

they are no longer engaged 
(see also parameter 18).

Y

 = closes when FSW is no longer 

engaged

no

 = disabled

18

When this function is activated and if the parameter 

17

 is 

Y

, the unit will wait for the opening 

cycle to end before executing the closing command sent by the

 CLOSING SAFETY 

DEVICES

.

Y

 = closes at the end of opening

no

 = disabled

19

When this function is activated, during closing, 

LOOP2

 stops and allows motion to resume 

when no longer engaged, otherwise it immediately reverses to opening.

Y

 = closes when no longer engaged

no

 = immediate reversal

20

When this function is activated, 

LOOP2

 commands closing when it is no longer engaged 

(see also parameter 

21

). 

Y

 = closes if 

LOOP2

 is clear

no

 = disabled

2 1

When this function is activated and if the parameter 

20

 is 

Y

, the unit will wait for the 

opening cycle to end before executing the closing command sent by 

LOOP2

.

Y

 = closes at the end of opening

no

 = disabled

22

When this function is activated, the 

LOOP1

 commands have priority over those of 

LOOP2

Y

 = active

no

 = disabled

23

LOOP 1 

commands opening and, once completed, it closes if no longer engaged (useful 

in case of vehicle back-up with consecutive loops). If disabled, when 

LOOP 1

 is no longer 

engaged, it does not close.

Y

 = closes if 

LOOP1

 is clear

no

 = disabled

24

NOT USED

/

25

A.D.M.A.P Function

When this function is activated, the result is operation of 

safety devices compliant with 

French standards.

Y

 = active

no

 = disabled

26

When this function is activated, the

 CLOSING SAFETY DEVICES

 during closing stop and 

reverse movement when they are no longer engaged, otherwise they reverse immediately.

Y

 = stops and reverses when no 

longer engaged.

no

= reverses immediately

27

NO EFFECT

/

A 1

PRE-FLASHING:

Lets you adjust, in 1 sec steps, the desired duration of pre-

fl

 ashing, from a minimum of 

00

 to 

a maximum of 

10

 seconds

05

A2

TIMEOUT FOR REVERSE WHEN CLOSING:

If this function is activated, during closing you can decide to reverse or stop movement when 
the timeout elapses (the closing limit switch is not reached).

Y

  = reverses

no

 = stops

A3

OPENING AT POWER UP:

In the event of a power failure, once it is restored, you can command opening by enabling 
this function (only if the automated system is not closed, FCC clear).

Y

  = opens

no

 = remains stationary 

St

AUTOMATED SYSTEM STATUS:

Exit programming, store settings and return to gate status display (see paragraph 11.5.1.).

11.8.1.  PERSONALISING THE OPERATING LOGIC

The expert programming level values vary depending on the operating logic chosen at the basic programming level.

The expert programming level is for personalising one of the selectable logics should a non-standard operating mode be required.

To make effective the change of one or more expert programming level parameters that personalise the set operating logic, proceed 

as follows:

Select the basic logic that most suits your needs.

Enter the expert programming level and change the desired parameters.
Exit expert level from the basic level and select the logic 

Cu

.

The logic 

Cu

 activates the changes made at expert level.

Содержание C850

Страница 1: ...C850 C850...

Страница 2: ...ll be integrated or of which it will become a component has been identified and declared as conforming to the conditions of Directive 2006 42 EEC and subsequent amendments Bologna 01 01 2012 The Manag...

Страница 3: ...m or greater Use of a 6A thermal breaker with all pole circuit break is recommended 13 Make sure that a differential switch with threshold of 0 03 A is fitted upstream of the system 14 Make sure that...

Страница 4: ...1 ACCESSORIES FIG 28 15 11 4 2 PHOTOCELL CONNECTION TO RELAYS AND SAFETY DEVICES WITH N C CONTACT 16 11 4 3 BUS PHOTOCELL CONNECTION 16 11 4 4 TERMINAL BOARD J2 FLASHING LAMP FIG 28 17 11 4 5 TERMINAL...

Страница 5: ...n the motor is stopped and therefore does not require an electric lock A handy manual release makes it possible to manoeuvre the gate in case of black out or operator inefficiency C850 TECHNICAL SPECI...

Страница 6: ...l stops of the gate The final adjustment is made once the inverter programming procedure is completed Minimum distance 3 cm The gate sliding rail must be linear and horizontal Manual movement of the g...

Страница 7: ...ion plate using one or more sheaths for running the electrical cables through the hole in the foundation plate Use a level to ensure that the plate is perfectly horizontal 4 Wait for the cement to set...

Страница 8: ...f 3 Usetheadjustmentscrewstosettheheightofthegearmotor Fig 10 ref referring to the measurements in Fig 12 4 Use a level to ensure that the gearmotor is perfectly horizontal 5 Move the gearmotor horizo...

Страница 9: ...wn in Fig 16 6 Manuallymovethegateandweldthethreethreadedpawls con tinuing until the gate is completely covered 5 4 2 SCREW ON STEEL RACK Fig 14 Before installing the rack release the gearmotor as des...

Страница 10: ...its travel 6 OPERATION 6 1 CONNECTING THE CONTROL BOARD Before carrying out any work on the board connections programming maintenance always cut off the electrical power Follow points 10 11 12 13 and...

Страница 11: ...ning limit switch Fig 21 ref until the microswitch is engaged by the cam 6 In chart 1 knowing the weight of the sliding leaf choose the operating speed and calculate the corresponding MINIMUM STOP SPA...

Страница 12: ...Manually close the sliding leaf 20 Prepare the operator for NORMAL operation as described in section 8 21 Ensure that there is no danger and the safety devices are operating correctly 22 Give an OPEN...

Страница 13: ...ustomer the User s Manual and show how to correctly operate and use the gearmotor pointing out the areas of potential danger of the automated system 8 RELEASING LOCKING THE OPERATOR To manually move t...

Страница 14: ...t temperature from 20 C to 55 C Protection F1 F 5A 250V F2 T 0 8A 250V or F1 F 10A 120V F2 T 0 8A 120V Operating time Programmable from 0 to 4 min Pause time Programmable from 0 to 4 min Programming 3...

Страница 15: ...STOP STOP contact N C terminal 8 means any device e g button which by opening a contact can stop movement of the automated system If STOP devices are not connected jumper terminals STOP and GND Fig 32...

Страница 16: ...sk of impact If the connection of two or more safety devices is required N C contacts they must be placed in series as shown in figures 29 30 and 31 under the wording SAFE Fig 30 Fig 29 Connection wit...

Страница 17: ...netothermic switch has been installed upstream 11 4 6ConnectorsJ3 J5 rapidconnectionopeningandclosinglimitswitches FIG 28 Rapid connector for connecting the opening J3 and closing J5 limit switches 11...

Страница 18: ...HAND opening the connections will be inverted on site as shown in figures 36 and 37 Fig 36 GATE WITH RIGHT HAND OPENING DEFAULT GATE WITH LEFT HAND OPENING 2 1 OMRON INVERTER 17 15 E850 2 T U O 3 T U...

Страница 19: ...C850 19 532015 Rev B Translation of the original instructions ENGLISH Fig 37 RIGHT HAND OPENING DEFAULT LEFT HAND OPENING...

Страница 20: ...e BOOST LOOP1 function no S 1 LOOP 1 SENSITIVITY Regulates the sensitivity of the loop 01 minimum 10 maximum 05 S2 LOOP 2 SENSITIVITY Regulates the sensitivity of the loop 01 minimum 10 maximum 05 St...

Страница 21: ...nt OFF means that no corresponding BUS device is active engaged when the gate is closed at rest BUS STATUS segment always on At the BASIC programming level there will be the parameter bu for BUS devic...

Страница 22: ...zer 16 FCA engaged 17 FCC engaged P4 OUTPUT 1 POLARITY Lets you configure the output polarity Y N C polarity no N O polarity Note if the output is set as FAIL SAFE 00 leave the value on no no Display...

Страница 23: ...NSITIVITY By adjusting the sensitivity you determine the variation of inductivity for each channel which a vehicle must cause in order to activate the corresponding detector output Sensitivity is adju...

Страница 24: ...the OPEN command during pause causes closing If the parameters 07 and 08 are no OPEN resets the pause time Y closes when paused no disabled 09 When this function is activated the OPEN command during c...

Страница 25: ...closing command sent by LOOP2 Y closes at the end of opening no disabled 22 When this function is activated the LOOP1 commands have priority over those of LOOP2 Y active no disabled 23 LOOP 1 commands...

Страница 26: ...sabled AT CLOSURE reopens the gate no effect stops operation no effect reverses to opening see 2nd lev prog stops and when no longer engaged opens stores CLOSE STOPPED closes the gate closes the gate...

Страница 27: ...gate no effect OPEN CLOSE disabled no effect no effect CLOSE disabled no effect OPEN CLOSE disabled AT CLOSURE reopens the gate no effect stops operation no effect reverses to opening see 2nd lev prog...

Страница 28: ...ys the important data such as reference frequency output current and set values Data display LED On depending on the indication on the data display Hz frequency A current RUN command LED On when the R...

Страница 29: ...from d001 mode to any operating mode press and hold the Mode key for 3 seconds o Note always press enter to store modified data ENTER key Enters and stores modified data To change the set value rememb...

Страница 30: ...rameter group A appears press the BLUE button and the display will show A001 press one of the two GREY buttons until A021 appears press the BLUE button and the display will show the value of the param...

Страница 31: ...P Gain 1 0 A073 PID I Gain 1 0 Sec A074 PID D Gain 0 00 Sec Contents Description Value Unit A075 PID Scale 1 00 Times A076 PID feedback selection 00 A077 Inverted PID function 00 A078 PID output limi...

Страница 32: ...C028 AM selection 00 C031 Multi function output 11 terminal contact selection 00 C036 Relay output contact selection AL2 AL1 01 C038 Light load signal output mode 01 C039 Light load detection level 7...

Страница 33: ...n the inverter 3 Check the RUNNING SPEED inverter parameter A021 and reduce the speed if necessary 4 Check the MINIMUM STOP SPACE in chart 1 in section 6 2 FINALADJUSTMENT OF THE LIMIT SWITCHES and if...

Страница 34: ...mming keyboard is an optional accessory for remotely programming the inverter parameters using the provided RJ45 standard cable connection The keyboard memory lets you save and store up to 4 customise...

Страница 35: ...command by radiocontrol or from another suitable device it activates the motor until the opening position is reached If automatic operation was set the gate re closes automatically after the selected...

Страница 36: ...__________________________ Technician Customer _____________________________________________ _____________________________________________ _____________________________________________ _______________...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...79 6645 faactm info faacgroup com www faac de INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com IRELAND NATIONAL AUTOMATION LIMITED Boyle Co Roscommon Ireland tel 35...

Отзывы: