A952 77
532310 - Rev.A
MENU 5 COUNTERS
1 CYCLES COUNT
CYCLES NUMBER
The display shows the number of cycles performed:
ABSO-
LUTE RELATIVE
MAINTENANCE
Technician PSW required. Allows the maintenance request to be
specified when a number of cycles has been reached. If a date is
also entered, a maintenance request is made when the first event
is reached: cycles or date.
MAINTENANCE CYCLES: 1000…1000000 counting the RELATIVE
cycles
DATE: optional. 00/00/00 = disabled
CYCLES RESET
Technician PSW required. It resets the RELATIVE cycle counter to
zero. This command requires confirmation The ABSOLUTE cycles
counter can only be reset using the restore factory settings procedure
(see relative Section).
2 SAFE FLOW
This function counts the people entering/leaving the premises for
capacity and queue management.
The counting of entrances and exits takes place by the activation of
the internal and external buttons. The A952 can be programmed to
indicate, and if necessary, close the entrance, when the set maximum
number of people on the premises has been reached.
The count is disabled in Door Opened mode. MANUAL and NIGHT
modes zero the count.
NOTE: In an INTERCOM network, the SAFE FLOW has to be pro-
grammed on the PRIMARY unit. Then it can also be enabled on
the individual SECONDARY boards via the PEOPLE IN SECONDARY
parameter, which is displayed only on the SECONDARY.
FUNCTION
DISABLED: count disabled
PEOPLE IN AUTO: activates the count of people entering and
leaving and displays the number of people inside on the KP EVO
HOME page in relation to the maximum number set. Alarm 40
is triggered when the set maximum number of people is reached
PEOPLE IN EXIT ONLY: activates the count of people entering and
leaving and displays the number of people inside on the KP EVO
HOME page in relation to the maximum number set. Alarm 40
is triggered when the set maximum number of people is reached
and the door does not allow other people to enter, they can only
leave, until the number of people falls below the maximum set
number again.
PEOPLE IN NUMBER
Sets the maximum number of people allowed inside: 1…1000
PEOPLE IN UPDATE
It allows the number of people inside to be corrected manually,
if necessary.
MENU 6 DATE / TIME
1 SET DATE
Set the date in the day/month/year format.
2 SET TIME
Set the time in hours and minutes.
3 DAYLIGHT SAV TIME
Enables/disables the automatic updating of daylight saving time.
MENU 7 TIMER
The TIMER function allows the operating mode of the automation
to be activated for programmed time bands. The operating mode
activated automatically by the TIMER cannot be changed manually,
unless you disable the TIMER.
Programming is carried out via the KP EVO, it requires a clock
battery to be installed on the board E952CL and the date and time
to be set correctly.
Programming can be done by day of the week (WEEKLY) and/or
by calendar date (JOLLY), e.g. for holidays, company closure... If
both have been programmed, in the event of an overlap, the JOLLY
has priority.
A TIME BAND is programmed with:
BEGINNING time - END time (HH:mm)
Operating mode
1 or more TIME BANDS can be programmed (max 6) in 24 h.
When the automation exits from a programmed TIME BAND, if there
is no subsequent time band, it goes into AUTOMATIC TWO-DIREC-
TIONAL TOTAL mode. Outside of the programmed time bands, the
Operating mode can be changed manually (from a Configured input
or Function selector).
WEEKLY PROGRAMMING
Program the required days with the required time bands. To quickly
program one or more time bands for a group of days, program the
group MON - SUN or MON - FRI. Next, each time band can be
reprogrammed for a single day.
JOLLY PROGRAMMING
Program the JOLLY time bands. The JOLLY programming must be
applied to the dates specified in JOLLY SLOTS.
A JOLLY SLOT is defined by the BEGINNING and END date of the
slot. Various JOLLY SLOTS can be programmed. A slot consisting
of one day has the same start and end date. A slot consisting
of several days cannot extend beyond December 31st.
E.g. the
period from December 25th to January 6th is covered by two
slots: 25…31/12 + 01…06/01.
ENABLING/DISABLING THE TIMER
Enable the TIMER in order to use the programmed time bands. Use
the input configured as TIMER, if present on the board. If there is
NO input configured as TIMER, the KP EVO can be used.
1 TIMER STATE
Allows the TIMER to be enabled/disabled: ENABLED, DISA-
BLED (the programming carried out remains in memory but is
not executed).