A952 56
532310 - Rev.A
ADVANCED programming
Default
rS
REVERSE STROKE
Commands a reverse stroke before opening, the dura-
tion of which is defined by parameter
Et
, to facilitate
the opening of the lock
no
= disabled
Y
= enabled
no
C1
C8
INPUTS CONFIGURATION IN1… IN8
0
= DISABLED
1 = EXTERNAL OPEN
4 = INTERNAL OPEN
7 = AUTOMATIC OPEN
8 = SEMIAUTOM. OPEN
10 = KEY
11 = PARTIAL OPEN
20 = CLOSING SAFETY
21 = OPENING SAFETY
22 = OVERHEAD PRESENCE SENSOR
30 = EMERGENCY OPEN
31 = EMERGENCY OPEN WITH MEMORY
34 = EMERGENCY CLOSE
35 = EMERGENCY CLOSE WITH MEMORY
36 = FIRE ALARM
40 = ALWAYS OPEN
41 = EXIT ONLY
42 = ONLY IN
43 = NIGHT
44 = MANUAL
45 = PARTIAL
46 = INTERLOCK
60 = TIMER
61 = RESET (contact type NO, non-modifiable)
89 = NURSE AND BED
90 = FIRE ALARM 2
91 = OPEN DELAY
*
1P
8P
CONTACT TYPE INPUTS IN1…IN8
Not displayed if the input is disabled or set as RESET
nO
= NO contact
nC
= NC contact
*
1F
8F
TEST (FAILSAFE) INPUTS IN1…IN8
Displayed only for functions
20
and
21
Y
= Test enabled
no
= Test not enabled
*
nd
SENSOR DELAY (in NIGHT MODE)
When NIGHT mode is set, the internal detector remains
active for the amount of time set in this parameter,
to allow it to be opened only once. The internal
detector is disabled immediately after opening and in
any case upon expiry of the set delay.
Adjustable from 0 to 90 s
10
ADVANCED programming
Default
od
OPEN DELAYTIME
Adjusts the time the door waits before opening after
an OPEN DELAY command from closed.
tL
SETUP
Carry out the SETUP procedure
In
IN OUT STATUS
The segments of the display indicate the status of the
inputs and outputs
St
EXIT PROGRAMMING
Exit from the programming function deciding whether
or not to save the changes
Y
= save
no
= do not save
After exit, the display shows automation status:
00 CLOSED
01 OPENING
02 OPENED
03 PAUSE
04 NIGHT PAUSE
05 CLOSING
06 EMERGENCY ACTIVE
07 MANUAL
08 NIGHT
11 STOP
13 ERROR