8. START-UP
Before starting up the system, make sure that the door
moves smoothly and without friction.
1. Turn power on to the A952.
2. Setting up the display.
3. Check that the status of the LEDS on the E952IO
board is correct.
4. Program the A952.
L
Make sure that you set the following parameters
correctly:
- parameter
9
t
,
for the type of arm actually installed
- parameter
S
9
,
according to the type of application
(opening or closing spring)
5. Carry out the SETUP procedure.
6. Carry out the final operations.
8.1 SETTING UP THE DISPLAY
Adjust the display using jumper J25 according to the
direction in which the board has been installed.
J25
J25
13
13
8.2 PROGRAM THE A952
Programming can be carried out from the board
KP EVO or from Simply Connect. For programming
via Simply Connect, see the specific documentation.
The operating parameters for a typical installation are
available for the programming from board function.
Programming from KP EVO/Simply Connect offers
a wider number of options. If values have been
programmed that are not available on the board, the
board’s display indicates them all with the value EP
(External Program). Programming from the board
can anyway modify values indicated by EP, but it is not
able to restore them.
8.3 ON BOARD PROGRAMMING
There is a function on the KP EVO that can be selected
which inhibits programming from the board.
Programming note:
-
Changes made to the parameters are only saved
when you exit from the programming function.
-
Programming is interrupted after 10 minutes if the
p
p
,
l
l
,
q
q
buttons have not been pressed, without
saving.
-
If there is a power failure during programming, any
unsaved changes have to be re-entered.
ACCESSING PROGRAMMING MODE
Programming the A952 is divided in to two levels:
BASIC and ADVANCED.
■
BASIC PROGRAMMING
-
Press and hold the
l
l
button: the first function
appears on the display.
-
Release the
l
l
button: the display shows the value
of the function.
■
ADVANCED PROGRAMMING
-
Press and hold buttons
l
l
and
p
p
: the first function
appears on the display.
-
Release buttons:
l
l
and
p
p
: the display shows the
value of the function.
MODIFYING THE PROGRAMMING
-
When the display indicates the value of the func-
tion, press the
p
p
or
q
q
button to modify it.
-
Press button
l
l
to go to the next function. The
function is displayed as long as the button remains
pressed.
EXITING PROGRAMMING MODE
-
Scroll through the menu until you reach the
St
function and release the
l
l
button.
-
Use the
p
p
or
q
q
buttons to select
Y
to save or
no
to discard any modifications.
-
Press
l
l
to confirm and exit from programming
mode.
L
Alternatively, press buttons
l
l
and
q
q
simultaneous-
ly at any point of the menu to save the modifications
and exit.