4.2 CONNECTIONS
CONTROL DEVICES
The control devices must be fitted with an open (NO)
or closed (NC) contact according to the input to which
they are connected. The device contact is connected
to the input to which they refer (IN1-IN8) and the
common negative (- COM).
L
Multiple NO contacts on the same input must be
connected in parallel.
Multiple NC contacts on the same input must be
connected in series.
The function and type of contact (NO/NC) can be pro-
grammed for all inputs. The default programming
functions are indicated below:
Default programming
Type of
contact
10
IN1 INTERNAL OPEN
NO
11
IN2 EXTERNAL OPEN
NO
12
IN3 EMERGENCY CLOSE
NC
13
IN4
CLOSING SAFETY DEVICE
NC
14
IN5 OPENING SAFETY DEVICE
NC
15
IN6 KEY
NO
16
IN7 FIRE ALARM
NO
17
IN8 AUTOMATIC OPEN
NO
A LED next to each input indicates its status:
-
LED on: input closed towards negative
-
LED off: input open
OUTPUTS
The A952 has 5 outputs on which both the function
and type of contact (NO/NC) can be programmed.
The outputs are activated according to the pro-
grammed function and are of the type:
-
Open Collector (OUT 1 and OUT 2)
OUT active
OUT not active
NO contact
0 V"
circuit open
NC contact
circuit open
0 V"
Do not exceed the maximum load of 100 mA for each
output.
-
Relay (OUT 3 , OUT4 and OUT 5)
OUT active
OUT not active
NO contact
circuit closed
circuit open
NC contact
circuit open
circuit closed
The maximum contact rating for each contact is 0.5
A 24 V
"
.
The default programming functions are indicated
below:
Default programming
Type of
contact
4
OUT 4
DOOR NOT CLOSED
NO
6
OUT 3
DOOR OPEN
NO
21 , 22 OUT 5
RED TRAFFIC LIGHT EXT
NO
23
OUT 1
GONG
NO
24
OUT 2
TEST
NC