A1400 AIR RDT
92
532119 04 - Rev. C
Tr
ansla
tion of the original instruc
tions
ENGLISH
2 Partial opening
Defines the opening percentage in PARTIAL OPENING mode. The
default and interval of settings is:
-
PARTIAL OPENING
100% (20-100)
3 AUX test time
Defines frequency (in hours) of the test on the Auxiliary_motor. The
default and interval of settings is:
-
AUX TEST TIME
24 H (2-24)
4 Board Display
Enables/disables programming from the board. The options with
relevant default are as follows:
-
Not blocked (Default)
-
Blocked
5 Safety Opening Function
Defines the safety in opening function
-
STOP
-
LOW ENERGY (slow speed motion) (Default)
6 Intrusion
Defines door behaviour in case of attempt to open manually. The
options with relevant default are as follows:
-
DISABLED does not actuate the motor (Default)
-
KEEP CLOSED counter: the motor is actuated in closing
-
PULL & GO the motor is actuated in opening
(
NOT active with battery operation)
7 Partial Chemist’s Shop
It defines the opening percentage with the pharmacy control (only
active in NIGHT-TIME Mode). The default and interval of settings is:
-
PARTIAL PHARMACY
20
% (1-95)
8 SDK EVO key
Defines function of key switch connected to SDK EVO (OPTIONAL
accessory):
-
BLOCK (Default):
With NO (Normally Open) key switch,
SDK EVO
it works normally. Password is required.
With NC (Normally Closed) key switch,SDK EVO it is blocked.
-
WITHOUT USER PSW:
With NO (Normally Open) key switch, SDK EVO it works without
password.
With NC (Normally Closed) key switch,SDK EVO it works normally.
Password is required.
9 Consecutive obstacles
Defines the number of consecutive obstacles after which the door is
blocked in error. Choose and modify the parameter:
-
CLOSING
from
0 to 3
(number of obstacles - default: 2)
-
OPENING
from
1 to 3
(number of obstacles - default: 1)
The block due to obstacles in opening cannot be DISABLED.
■
7 INSTALLATION
OK
OK
INSTALLATION
2
PROGRAMMING
1 Number of leaves
Set the number of leaves of the system:
-
1 LEAF (Default)
-
2 LEAVES
2 Start SETUP
This command requires confirmation to perform SETUP.
!
Comply with the procedure on
63
.
3 INPUT status
The display shows active inputs. In the example safety sensor S2 is on:
INPUT STATUS
IN4
S4
FSW2
OK
IN1
S1
INT
SM
IN2
S2
EXT
E1
IN3
S3
FSW1
E2
4 DOOR status
The display shows what status the door is in:
-
CLOSED
-
in OPENING
-
OPENED
-
in PAUSE
-
in NIGHT-TIME PAUSE
-
in CLOSING
-
EMERGENCY
-
MANUAL MODE
-
NIGHT-TIME MODE
-
AUX OPENING (opening with auxiliary_Motor)
-
BOARD TEST
-
STOP AND ERROR
-
SECURITIES TEST
-
ERROR
-
SERIOUS ERROR
-
SETUP IN PROGRESS
5 Other board data
The display reads:
-
V_MAIN (input voltage to board in Volt)
-
V_BATT (battery voltage in Volt)
-
V_ACC (accessory voltage in Volt)
-
I_MOT (current absorbed by the motor in Ampère)
-
POS (leaf position in cm)
■
8 SUNDRIES
OK
OK
MISCELLANEUS
2
PROGRAMMING
1 Default Configuration
-
ACTIVE (default configuration is present)
-
NO (default configuration has been modified)
To reset all parameters to default settings press the OK button and
confirm.