External n.c. CONTACT
-
External no CONTACT
-
Internal current
-
Internal frequency
-
External current
-
External frequency
5 Emergencies E1 / E2
1. Select input E1. The complete list with relevant default is:
-
E1
Opening /NO
-
E2
Opening /NO
Input E2 is non modifiable and performs the function set for E1.
2. Select function:
-
Opening with memory
-
Opening
-
Disabled
3. If the input is enabled, select the logic:
-
Normally open (NO)
-
Normally closed (NC)
6 XFA Photocells
XFA Photocell inputs are disabled by default.
1. Select:
-
Disabled
-
1 pair
-
2 pairs
■
2 MOTION
OK
OK
MOTION
2
PROGRAMMING
Opening
Choose and modify the parameter. The complete list with relevant
default and range of values is:
-
1 SPEED 10 (from 1 to 10)
-
2 SLOWDOWN 1 cm (from 0 to 200)
SLOWDOWN SPEED 1 (1-3)
-
3 FORCE 10 (non modifiable)
-
4 FORCE TIME 3.0s (cannot be modified)
-
5 ACCELERATION 10 (from 1 to 10)
-
6 DECELERATION 10 (from 1 to 10)
Closing
Choose and modify the parameter. The complete list with relevant
default and range of values is:
-
1 SPEED 3 (from 1 to 10)
-
2 SLOWDOWN 1 cm (from 0 to 2(00)
SLOWDOWN SPEED 1 (1-3)
-
3 FORCE 6 (from 1 to 10)
-
4 FORCE TIME 1.0s (from 0.1 to 3.0)
-
5 ACCELERATION 6 (from 1 to 10)
-
6 DECELERATION 6 (from 1 to 10)
-
7 INVERSION(*) 5 (from 1 to 5 )
* the INVERSION parameter determines the inversion speed of the
leaf in the closing stage with 5 level setting from 1 (slow) to 5 ( fast).
■
3 TIMING
OK
OK
TIMING
2
PROGRAMMING
Choose and modify the parameter. The complete list with relevant
default and range of values is:
-
1 PAUSE TIME 2s
(0-30)
-
2 NIGHT PAUSE TIME
10s (0-240)
-
3 NIGHT SENSOR DELAY 10s (0-240)
■
4 ENERGY SAVING
OK
OK
ENERGY SAVING
2
PROGRAMMING
The Energy Saving is disabled by default. Available options are:
-
ENABLED
-
DISABLED
■
5 BATTERY KIT
OK
OK
BATTERY KIT
2
PROGRAMMING
Defines the automation’s behaviour with emergency battery, in case of
mains power outage. The options with relevant default are as follows:
-
1 FUNCTION (Immediately last mov.)
-
2 LAST MOVEMENT (Opening)
-
3 NIGHT-TIME FUNCTION (Up to the last motion) (Default)
Selectable: Now last motion
-
4 NIGHT-TIME LAST MOTION (Closure) (Default)
Selectable: Opening
These settings are non modifiable.
If the door is in NIGHT-TIME, battery operation is not active.
■
6 MOTOR BLOCK KIT
OK
OK
MOTOR LOCK KIT
2
PROGRAMMING
Defines motor block behaviour (OPTIONAL accessory).
The options with relevant default are as follows:
-
1 TYPE
-
2 FUNCTION (Disabled)
-
3 MONITORING KIT (Disabled)
-
4 BATTERY OPERATION (NIGHT-TIME)
1 TYPE
Defines the type of motor block:
-
XB LOCK
-
XM LOCK
2 FUNCTION
Defines operating methods in which motor block is activated;
-
Disabled
-
Night
-
Night-time + Open
3 MONITORING KIT
Enables/disables monitoring on motor block;
-
ENABLED
-
DISABLED
If the monitoring kit (OPTIONAL accessory) is not installed, disable.
4 BATTERY OPERATION
Defines battery operation of the motor block:
-
STANDARD: the operation selected is maintained even with
battery.
-
NIGHT-TIME: motor block active only in NIGHT-TIME mode.
-
ALWAYS OPEN: motor block always OPEN
Содержание A1400 AIR RD