12.5 MOTOR BLOCK XM LOCK AND
MONITORING (OPTIONAL)
!
ALWAYS DISCONNECT the power supply and disconnect the emergency
battery before inserting or disabling the motor block, in order not to
damage the device.
1. Connect the motor release monitor (IF INSTALLED) on the release
terminal block
75
-C.
2. Connect the motor block to the control board by means of the
wired connector
75
-
.
3. Program motor block operation (
EL
EL
) and enable monitoring
SU
SU
.
A
EL
EL
=
no
no
(motor block not present )
EL
EL
=
3
3
(block inserted in NIGHT-TIME mode )
EL
EL
=
4
4
(block inserted in NIGHT-TIME and OPEN mode)
C
SU
SU
=
Y
Y
(monitoring enabled )
In the event of malfunctioning of the motor block the system signals
ERROR 26 on the display and on SDK EVO.
With SDK EVO the motor block operation may be programmed with
several options.
In the event of mains power failure, if the battery runs out the motor
block XM LOCK is disconnected.
1
DL11
J13
V G
I
I+
I-
J5
V G
E
E+
E-
J6
V G
S1
G
T
J1
V G
S2
G
T
J2
V G
S3
G
T
J3
V G
S4
G
T
J4
V RX
TX G
J8
E1 G E2
J7
T1 G
T2
R1
G R2
J9
V G 01 02 02
J22
J21
V
G
I1
I2
G
I3
I4
V
J18
G CH CL
G
J13
1
2
C
1
2
J13
A
C
4
5
3
2
1
75
1
green
C
Motor block monitor
2
pink
4
white
A
Motor block
5
brown