A1400 AIR RDT
25
532119 04 - Rev. C
17
16
1
3
2
x2
1
18
2
3
75501500 2015
75501500 2015
Tr
ansla
tion of the original instruc
tions
ENGLISH
COVER DRILLING
Make a diameter 18 mm hole on the
diameter 18 mm hole on the lengthwise marking on the
cover
16
-
.
The hole must be centred with respect to the release knob.
CLOSED DOOR MONITOR SENSOR
(OPTIONAL ACCESSORY)
Assemble the magnet on the carriage closest to the closing stop.
1. Screw the magnet
17
-
on the carriage (use the threaded
hole normally used to attach the belt).
2. Assemble the sensor to the bracket with the suitable plastic nuts
17
-
.
3. Insert a threaded plate with screw in the support profile housing
and fasten the bracket
17
-
.
After installing the door the position must be checked to ensure sensor
and magnet are aligned when the door is closed.
EMERGENCY BATTERY KIT
1. Insert two plates in the support profile as shown in
18
.
2. Fasten the battery support on the support profile with 2 screws
and washers (provided).
!
Check the label on the emergency battery with date and logo through
the window on battery support plate .
18
-
.
2
6
6
Nm
year of manufacture (yyyy)
Sale code
IDENTIFICATION NUMBER
example: