background image

GC4400 SERIES

DOOR CLOSER

INSTALLATION & INSTRUCTION SHEET

PUSH SIDE MOUNTED (PARALLEL ARM) D.S

Standard Installation

Install on Drop Plate

GENERAL NOTES

GC4400 SERIES closer is non handed and designed to meet
entrance accessibility requirements. Before installation ,
detemine hand of door first . Refer to the drawing (right).

GC4400 SERIES closer can be adjusted to handle all exterior
doors up to 48" and interior doors up to 60" wide. Adjust the

spring power as shown before installing the closer. Turn the
spring adjustment nut clockwise or counter-clockwise the

required number of turns to match door width as indicated in

chart below.

  MAXIMUM

DOOR WIDTH

     FULL
  TURNS

REQUIRED

INTERIOR

  DOORS

EXTERIOR

  DOORS

8.5lb-1*

5lb-1*

38"

36"

42"

48"

34"

30"

48"

54"

60"

5 Turns C.C.W

2 Turns C.C.W

0Turns

5 Turns C.W

10 Turns C.W

15 Turns C.W

* Opening  Force on 36" Door.

IMPORTANT-When adjusting spring power , DO NOT

exceed the maximum  number of turns in either
direction! Beyond either maximum number of turns

may damage closer.

To decrease
spring power

C.C.W

To increase
spring power

C.W

+

-

 HOW TO TELL

HAND  OF DOOR

OUTSIDE

LEFT HAND

   DOOR

RIGHT HAND

    DOOR

CLOSER CONTROL DIAGRAM

LATCH SPEED

MAIN SPEED

BACKCHECK

Page 1

GCNSA440

 ‐ 

Cush

N

Stop

 

Arm

 

for

 

GC4400

GHCHA440

 ‐ 

Handle

 

Control

 

Hold

 

Open

 

Arm

 

for

 

GC4400

Отзывы: