1) ATTENTION! To ensure the safety of people, it is important that you read

all the following instructions. Incorrect installation or  incorrect use of
the product  could  cause  serious harm   to people.

2) Carefully read the instructions before beginning to install the product.

3) Do not  leave packing materials (plastic, polystyrene, etc.)   within  reach

of  children as  such materials  are  potential  sources  of  danger.

4) Store these instructions for  future reference.

5) This product was designed and built strictly for the use indicated in this

documentation. Any other use, not expressly indicated here, could
compromise the good condition/operation of the product and/or be a
source of danger.

6) FAAC declines all liability caused by improper use or use other than that

for which the automated system was intended.

7) Do not install the equipment in an explosive atmosphere: the presence

of  inflammable gas or fumes is a serious danger to safety.

8) The mechanical parts must conform to the provisions of Standards EN

12604 and EN 12605.
For non-EU countries, to obtain an adequate level of safety, the Standards
mentioned above must be observed, in addition to national legal
regulations.

9) FAAC is not responsible for failure to observe Good Technique in the

construction of the closing elements to be motorised, or for any
deformation that may occur during use.

10) The installation must conform to Standards EN 12453 and EN 12445.

 For non-EU countries, to obtain an adequate level of safety, the Standards
mentioned above must be observed, in addition to national legal
regulations.

11) Before attempting any job on the system, cut out electrical power .

12) The mains power  supply of the automated system must be fitted with an

all-pole  switch with contact opening distance of 3mm or greater. Use of
a 6A thermal breaker with all-pole circuit break is recommended.

13) Make sure that a differential switch with threshold of 0.03 A is fitted

upstream of the system.

14) Make sure that the earthing system is perfectly constructed, and

connect metal parts of  the means of the closure to it.

15) The safety devices (EN 12978 standard)  protect any danger areas

against

mechanical movement Risks

, such as crushing, dragging,

and shearing.

16) Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended

for every system, as well as a warning sign adequately secured to the
frame structure, in addition to the devices mentioned at point “15”.

17) FAAC declines all liability as concerns safety and efficient operation

of the automated system, if system components not produced by
FAAC are used.

18)

For maintenance, strictly use original parts by FAAC.

19) Do not in any way modify the components of the automated system.

20) The installer shall supply all information concerning manual operation

of the system in case of an emergency, and shall hand over to the user
the warnings handbook supplied with the product.

21) Do not allow children or adults to stay near the product while it is

operating.

22) Keep remote controls or other pulse generators away from children,

to prevent the automated system from being activated involuntarily.

23) Transit through the leaves is allowed only when the gate is fully open.

24) The user must not attempt any kind of repair or direct action whatever

and contact qualified personnel only.

25) Maintenance: check at least every 6 months the efficiency of the

system, particularly the efficiency of the safety devices (including,
where foreseen, the operator thrust force) and of the release devices.

26) Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

EC DECLARATION OF CONFORMITY FOR MACHINES

(DIRECTIVE 98/37/EC)

Manufacturer:

FAAC S.p.A.

Address:

Via Benini, 1  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that:

422  mod.  operator,

• is built to be integrated into a machine or to be assembled with other machinery to create a machine under

the provisions of Directive 98/37/EC;

• conforms to the essential safety requirements of the following EEC directives:

73/23/EEC and subsequent amendment  93/68/EEC.
89/336/EEC and subsequent amendment  92/31/EEC and 93/68/EEC

and also declares that it is prohibited to put into service the machinery until the machine in which it will be
integrated or of which it will become a component has been identified and declared as conforming to the
conditions of Directive 98/37/EC.

Bologna, 01 January 2005

The Managing Director

A. Bassi

Содержание 104200177

Страница 1: ...Leading the way Installation Manual 422 Leading the way Swing Gate System...

Страница 2: ...OMATED SYSTEM TEST p 16 7 MANUAL OPERATION p 16 8 RESTORING NORMAL OPERATION MODE p 17 9 SPECIAL APPLICATIONS FOR SWING LEAF GATES p 17 9 1 OPENING TOWARD THE OUTSIDE WITH OPERATOR INSTALLED INSIDE p...

Страница 3: ...ger areas against mechanical movement Risks such as crushing dragging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequa...

Страница 4: ...ys separate the connection cables of the low voltage accessories from the 230 V power cables Use separate sheaths to avoid any type of interference Fig 3 Fig 2 E P Y T R O T A R E P O D R A D N A T S...

Страница 5: ...unctionality we recommend you to respect the indicated dimensions For iron pilasters accurately weld the rear attachment ref Fig 6 directly on the pilaster For masonry pilasters select one of the foll...

Страница 6: ...two weld spots protecting the rod against any welding waste NB If the gate structure does not permit the attachment to be firmly fastened take action on the structure creating a solid support base 10...

Страница 7: ...e bend guard ref Fig 14 14 Re lock the operator and make the electrical connections of the selected electronic control unit following the relevant instructions Fig 11 Fig 12 4 START UP 4 1 ADJUSTING T...

Страница 8: ...Finish the installation operations as follows Close the cover of the release device with the key Remove the breather screw Fig 14 ref 6 AUTOMATED SYSTEM TEST When you have finished installing apply t...

Страница 9: ...ening direction To reduce torque turn the screws anti clockwise To increase torque turn the screws clockwise Fig 16 Table C Recommended dimensions for standard operators Rod effective stroke maximum d...

Страница 10: ...t p a h c w e r c s r e h t a e r b e h t d e v o m e r e v a h u o y t a h t e r u s e k a M r i a y n a e s a e l e r o t r e d r o n i s e l c y c g n i s o l c d n a g n i n e p o e t a g e t e l...

Страница 11: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ n a i c i n h c e T r e m o t s u C 9 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 12: ...ric lock as they guarantee mechanical locking of the leaf when the motor is not operating The other models without a hydraulic locking always require one or more electric locks to ensure the leaf is m...

Страница 13: ...12 QRWH QRWHV QRWH QRWDV DQPHUNXQJ RSPHUNLQJHQ...

Страница 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...

Отзывы: