- Turn the key 90°clockwise to open the cover.
- Lift up the cover (Fig. 13).
- Back off the screw (Fig. 13, ref. 

) which secures the knob, and

withdraw the knob (Fig. 13, ref. 

).

- Turn the force adjustment screws (By-Pass) (Fig. 13, ref. 

 and 

)

on the operator.

- OPEN screw (green wording) : gate opening direction.
- CLOSE screw (red wording)    : gate closing direction.
- To reduce torque, turn the screws anti-clockwise.
- To increase torque, turn the screws clockwise.
- When you have finished adjusting, re-position the knob (Fig. 13,

ref. 

) and fasten the screw (Fig. 13, ref. 

).

- Close the cover and lock it by turning the key anti-clockwise.

To adjust the torque limiters, consult Standards EN 12453 and EN
12445 for EU member countries and current legal regulations in
the other countries.

Fig. 13

Fig. 15

Fig. 14

 5.

FINAL OPERATIONS

Finish the installation operations as follows:
- Close the cover of the release device with the key.
- Remove the breather screw (Fig.14, ref. 

)

6.

AUTOMATED SYSTEM TEST

When you have finished installing, apply the danger signal sticker
on the side of the operator so that it is clearly visible (Fig.15).
Run an accurate functional check of the automated system and
of all the accessories connected to it, especially the safety devices.
Hand the “User’s Guide” to the Client, explain correct operation
and use of the operator, and indicate the potentially dangerous
areas of the automated system.

7.

MANUAL OPERATION

If the gate has to be moved manually due to a power cut or fault
of the automated system, use the release device as follows:
- Lift the protective plug (Fig. 16, ref. 

) and fit the supplied key

(Fig. 16, ref. 

).

- Turn the key 90°clockwise to open the cover.
- Lift up the cover (Fig. 16 ref.

 

).

- Turn the release knob anti-clockwise for about two turns (Fig. 16,

ref. 

).

- Open or close the leaf manually.

Содержание 104200177

Страница 1: ...Leading the way Installation Manual 422 Leading the way Swing Gate System...

Страница 2: ...OMATED SYSTEM TEST p 16 7 MANUAL OPERATION p 16 8 RESTORING NORMAL OPERATION MODE p 17 9 SPECIAL APPLICATIONS FOR SWING LEAF GATES p 17 9 1 OPENING TOWARD THE OUTSIDE WITH OPERATOR INSTALLED INSIDE p...

Страница 3: ...ger areas against mechanical movement Risks such as crushing dragging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequa...

Страница 4: ...ys separate the connection cables of the low voltage accessories from the 230 V power cables Use separate sheaths to avoid any type of interference Fig 3 Fig 2 E P Y T R O T A R E P O D R A D N A T S...

Страница 5: ...unctionality we recommend you to respect the indicated dimensions For iron pilasters accurately weld the rear attachment ref Fig 6 directly on the pilaster For masonry pilasters select one of the foll...

Страница 6: ...two weld spots protecting the rod against any welding waste NB If the gate structure does not permit the attachment to be firmly fastened take action on the structure creating a solid support base 10...

Страница 7: ...e bend guard ref Fig 14 14 Re lock the operator and make the electrical connections of the selected electronic control unit following the relevant instructions Fig 11 Fig 12 4 START UP 4 1 ADJUSTING T...

Страница 8: ...Finish the installation operations as follows Close the cover of the release device with the key Remove the breather screw Fig 14 ref 6 AUTOMATED SYSTEM TEST When you have finished installing apply t...

Страница 9: ...ening direction To reduce torque turn the screws anti clockwise To increase torque turn the screws clockwise Fig 16 Table C Recommended dimensions for standard operators Rod effective stroke maximum d...

Страница 10: ...t p a h c w e r c s r e h t a e r b e h t d e v o m e r e v a h u o y t a h t e r u s e k a M r i a y n a e s a e l e r o t r e d r o n i s e l c y c g n i s o l c d n a g n i n e p o e t a g e t e l...

Страница 11: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ n a i c i n h c e T r e m o t s u C 9 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 12: ...ric lock as they guarantee mechanical locking of the leaf when the motor is not operating The other models without a hydraulic locking always require one or more electric locks to ensure the leaf is m...

Страница 13: ...12 QRWH QRWHV QRWH QRWDV DQPHUNXQJ RSPHUNLQJHQ...

Страница 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...

Отзывы: