7
- Turn the key 90°clockwise to open the cover.
- Lift up the cover (Fig. 13).
- Back off the screw (Fig. 13, ref.
) which secures the knob, and
withdraw the knob (Fig. 13, ref.
).
- Turn the force adjustment screws (By-Pass) (Fig. 13, ref.
and
)
on the operator.
- OPEN screw (green wording) : gate opening direction.
- CLOSE screw (red wording) : gate closing direction.
- To reduce torque, turn the screws anti-clockwise.
- To increase torque, turn the screws clockwise.
- When you have finished adjusting, re-position the knob (Fig. 13,
ref.
) and fasten the screw (Fig. 13, ref.
).
- Close the cover and lock it by turning the key anti-clockwise.
To adjust the torque limiters, consult Standards EN 12453 and EN
12445 for EU member countries and current legal regulations in
the other countries.
Fig. 13
Fig. 15
Fig. 14
5.
FINAL OPERATIONS
Finish the installation operations as follows:
- Close the cover of the release device with the key.
- Remove the breather screw (Fig.14, ref.
)
6.
AUTOMATED SYSTEM TEST
When you have finished installing, apply the danger signal sticker
on the side of the operator so that it is clearly visible (Fig.15).
Run an accurate functional check of the automated system and
of all the accessories connected to it, especially the safety devices.
Hand the “User’s Guide” to the Client, explain correct operation
and use of the operator, and indicate the potentially dangerous
areas of the automated system.
7.
MANUAL OPERATION
If the gate has to be moved manually due to a power cut or fault
of the automated system, use the release device as follows:
- Lift the protective plug (Fig. 16, ref.
) and fit the supplied key
(Fig. 16, ref.
).
- Turn the key 90°clockwise to open the cover.
- Lift up the cover (Fig. 16 ref.
).
- Turn the release knob anti-clockwise for about two turns (Fig. 16,
ref.
).
- Open or close the leaf manually.