USER’S GUIDE

Read the instructions carefully before using the product and store
them for future use

GENERAL SAFETY REGULATIONS

If correctly installed and used, the 422 automated system ensures
a high degree of safety.
Some simple rules on behaviour can prevent accidental trouble:
-

Do not pass between the leaves when they are moving. Wait
for the leaves to open fully before passing through them.

-

Do not, on any account stay in between the leaves.

-

Do not stand near the automated system, and do not allow
children, persons or things to do so, especially when it is
operating.

-

Keep remote controls or other pulse generators away from
children, to prevent the automated system from being
activated involuntarily.

-

Do not allow children to play with the automated system.

-

Do not willingly obstruct leaves movement.

-

Prevent any branches or shrubs from interfering with leaves
movement.

-

Keep indicator-lights efficient and easy to see.

-

Do not attempt to activate the leaves by hand unless you
have released them.

-

In the event of malfunctions, release the leaves to allow access
and wait for qualified technical personnel to do the necessary
work.

-

When you have set manual operation mode, cut power to
the system before restoring normal operation.

-

Do not in any way modify the components of the automated
system.

-

Do not attempt any kind of repair of direct action whatever
and contact qualified personnel only.

-

At least every six months: arrange a check by qualified
personnel of the automated system, safety devices and earth
connection.

DESCRIPTION

These instructions apply to the following models:

422 CBCS - 422 CBACS - 422 SBS - 422 CBC - 422 CBAC -
422 SB - 422 CBC PED. - 422 SB PED.

The FAAC 422 automated system for swing leaf gates consists of
a hydraulic enbloc composed of an electric pump and a
hydraulic piston which transmits drive to the leaf.
The models with a hydraulic locking do not require installation of
an electric lock, as they guarantee mechanical locking of the
leaf when the motor is not operating.

The other models, without a hydraulic locking always require one
or more electric locks to ensure the leaf is mechanically locked.
Leaves of up to 3 mt can be automated depending on the
selected model.
The functioning of the operators is controlled by an electronic
control unit, housed in an enclosure with adequate degree of
protection against atmosphere agents.
The leaves are normally closed.
When the electronic control unit receives an opening command
from the radio control or any other pulse generator, it activates
the hydraulic appliance which rotates the leaves until they reach
the opening position to allow access.
If automatic mode was set, the leaves close automatically after
selected pause time has elapsed.
If the semi-automatic mode was set, a second pulse must be sent
to close the leaf again.
A stop pulse (if supplied) always stops movement.
For details on the behaviour of the automated system in different
function logics, consult the installer.
Automated systems include safety devices (photocells) that
prevent the leaves from moving when there is an obstacle in the
area they protect.
The 422 automated system is supplied standard with a hydraulic
anti-crush protection safety device (BY-PASS) which limits the
torque transmitted to the leaves.
The warning-light indicates the current leaf movement.

MANUAL OPERATION

If the gate has to be moved manually due to a power cut or fault
of the automated system, the release unit must be temporarily
opened (fig.1).
- Remove the protective plug and insert the supplied key.
- Turn the key 90°clockwise to open the cover.
- Lift up the cover.
- Turn the release knob anti-clockwise for about two turns.
 Open or close the leaf manually.
N.B.: IN MODELS WITHOUT THE LOCKS, ALL YOU HAVE TO DO IS TO
MANUALLY RELEASE THE ELECTRIC LOCK.

RESTORING NORMAL OPERATION MODE

Before re-locking the operator, cut power to the system. Turn the
release knob clockwise until it stops.
Close the cover and turn the key 90° anti-clockwise. Finally, remove
the key and close the protective plug.

AUTOMATED SYSTEM 422

Fig. 1

Содержание 104200177

Страница 1: ...Leading the way Installation Manual 422 Leading the way Swing Gate System...

Страница 2: ...OMATED SYSTEM TEST p 16 7 MANUAL OPERATION p 16 8 RESTORING NORMAL OPERATION MODE p 17 9 SPECIAL APPLICATIONS FOR SWING LEAF GATES p 17 9 1 OPENING TOWARD THE OUTSIDE WITH OPERATOR INSTALLED INSIDE p...

Страница 3: ...ger areas against mechanical movement Risks such as crushing dragging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequa...

Страница 4: ...ys separate the connection cables of the low voltage accessories from the 230 V power cables Use separate sheaths to avoid any type of interference Fig 3 Fig 2 E P Y T R O T A R E P O D R A D N A T S...

Страница 5: ...unctionality we recommend you to respect the indicated dimensions For iron pilasters accurately weld the rear attachment ref Fig 6 directly on the pilaster For masonry pilasters select one of the foll...

Страница 6: ...two weld spots protecting the rod against any welding waste NB If the gate structure does not permit the attachment to be firmly fastened take action on the structure creating a solid support base 10...

Страница 7: ...e bend guard ref Fig 14 14 Re lock the operator and make the electrical connections of the selected electronic control unit following the relevant instructions Fig 11 Fig 12 4 START UP 4 1 ADJUSTING T...

Страница 8: ...Finish the installation operations as follows Close the cover of the release device with the key Remove the breather screw Fig 14 ref 6 AUTOMATED SYSTEM TEST When you have finished installing apply t...

Страница 9: ...ening direction To reduce torque turn the screws anti clockwise To increase torque turn the screws clockwise Fig 16 Table C Recommended dimensions for standard operators Rod effective stroke maximum d...

Страница 10: ...t p a h c w e r c s r e h t a e r b e h t d e v o m e r e v a h u o y t a h t e r u s e k a M r i a y n a e s a e l e r o t r e d r o n i s e l c y c g n i s o l c d n a g n i n e p o e t a g e t e l...

Страница 11: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ n a i c i n h c e T r e m o t s u C 9 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 12: ...ric lock as they guarantee mechanical locking of the leaf when the motor is not operating The other models without a hydraulic locking always require one or more electric locks to ensure the leaf is m...

Страница 13: ...12 QRWH QRWHV QRWH QRWDV DQPHUNXQJ RSPHUNLQJHQ...

Страница 14: ...for either technical or commercial reasons at any time and without revising the present publication FAAC UK Limited 6 Hamilton Close Houndmills Estate Basingstoke RG21 6YT Telephone 01256 318100 Fax 0...

Отзывы: