12
-18
SUUV-W00
Apr. 2011
SAFETY
FIRST
GENERAL
ENGINE
CVT
TRANSMISSION
CHASSIS
REAR AXLE
BRAKE
FRONT AXLE
STEERING
HYDRAULIC
ELECTRIC
INDEX
5.2 COOLING FAN MOTOR
The cooling fan motor is installed on the back of
the radiator under the hood.
UUVWA07A
OPERATION
The cooling fan motor is operated and stopped ac-
cording to the preset coolant temperature.
•
FAN MOTOR operated
Coolant temperature over
80˚C (176˚F)
FAN MOTOR stopped
Coolant temperature
below 75˚C (167˚F)
FAN MOTOR TEST
1. Turn the ignition switch to the “OFF” position and
disconnect the electric motor connector.
2. Connect the terminal (1) to the positive battery ter-
minal and the terminal (2) to the negative battery
terminal using a jump leads.
3. If the fan motor does not operate, replace it with a
new one.
UUVWA83A
Power
100W ± 10% (Max)
Rated speed
2060 rpm ± 10%
Rated voltage
DC 12V
Rated current
5 ~ 10A
Rotating direction
Counterclockwise
(seen from front)
Free play in motor shaft
direction
0.1 ~ 0.3 mm
MOTOR SPECIFICATIONS
1
2
⿸␔+O,
㪜␔+E,
UUVWA71A
Blue (L)
Black (B)
ELECTRIC SYSTEM - ELECTRICAL COMPONENTS
UTV(EZGO향)_12_ELECTRIC SYSTEM.in섹션1:18 섹션1:18
UTV(EZGO향)_12_ELECTRIC SYSTEM.in섹션1:18 섹션1:18
2011-04-04 오후 4:35:41
2011-04-04 오후 4:35:41
Содержание 1600xd
Страница 1: ...ISSUED APRIL 2011 1600xd 4x4 repair manual 619728...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 38: ...MEMO...
Страница 138: ...MEMO...
Страница 158: ...MEMO...
Страница 188: ...MEMO...
Страница 244: ...MEMO...
Страница 292: ...MEMO...
Страница 338: ...MEMO...
Страница 344: ......
Страница 407: ...CHAPTER 13 INDEX...
Страница 414: ...MEMO...
Страница 415: ......