XTP T FB 202 • SIS Configuration and Control
18
SIS Configuration
and Control
The XTP T FB 202 can be configured and controlled using Extron Simple Instruction
Set (SIS) commands or the XTP System Configuration Software (see
XTP System
Configuration Software
on page 24). This section contains basic SIS communication
details and SIS commands and responses when connected directly to the XTP T FB 202.
Topics in this section include:
•
Host Device Connection
•
SIS Programming Guide
•
Command and Response Tables for SIS Commands
Host Device Connection
Use a computer running the HyperTerminal or Extron DataViewer utility, or a control system
to enable serial control of the switcher. To connect directly to an XTP T FB 202, connect the
computer to the XTP T FB 202 through the top panel USB Config port or the side panel
RS-232 connector. The protocol for the serial port is as follows: 9600 baud, no parity, 8 data
bits, 1 stop bit, no flow control.
SIS Programming Guide
Host-to-Device and Device-to-Host Communication
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the XTP T FB 202 determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the switcher to the host end with a carriage return and a line feed
(CR/LF =
]
), which signals the end of the response character string. A string is one or more
characters.
Device-Initiated Message
When the transmitter is connected through the serial port only and a local event occurs, the
device responds by sending a message to the host.
The following copyright message is displayed after a power cycle via RS-232.
© Copyright 2013, Extron Electronics XTP T FB 202 Vx.xx, 60-1383-12
]
V
x.xx
is the firmware version number.