XTP T FB 202 • XTP System Configuration Software
34
EDID Minder
Use the EDID Minder screen to assign unique EDID to the input or match current output
resolutions to the input. Click the
EDID Minder
icon on the global navigation bar. The EDID
Minder screen opens.
The EDID Minder screen displays a table of EDID options and connected output devices,
which are each represented by output display icons. Factory default EDID options are
displayed in blue and connected output devices are displayed in green. Custom loaded or
saved EDID options are displayed in yellow. Output resolutions are displayed in green.
Figure 35.
EDID Minder Screen
Assign EDID
1.
Select an available EDID setting (represented by a blue, green, or yellow output display
icon) from the Favorites, Connected Outputs, or Available EDID pane.
2.
Select the check box of the connected input to the right of the Available EDID pane.
3.
Click the
Assign
button below the input area.
TIP:
Alternatively, EDID can be assigned by dragging and dropping the desired EDID
onto the input.
Import EDID
1.
On the EDID Minder screen, click the
Add EDID to Library
button.
2.
Select the desired EDID file and click
Open
. The EDID appears in the Available EDID
pane.
3.
Assign the EDID from the Available EDID pane to import the EDID setting to the device.
Save output EDID
1.
On the EDID Minder screen, right-click on the desired EDID setting in the
Connected
Outputs
pane.
2.
Select the
Save EDID to PC
option. The EDID setting is saved to the connected PC.
Alternatively, right-click on the desired EDID, select
Copy
, and then
Paste
the EDID into
the desired pane.