XTP T FB 202 • Installation
7
4.
If the desired position is position 2 of the Ackermann GB3 (OBO Bettermann) floor box,
use the provided screws to secure the 995242 adapter plate to a 995241 adapter plate.
Figure 6.
Installing the 995242 Adapter Plate to a 995241 Adapter Plate
Side Panel Connectors
Connectors Below the Adapter Plates
1.0 A MAX
SIG LINK
XTP OUT
G
REMOTE
RS-232
Rx Tx
POWER
12V
1.0A MAX
− +
Side Panel
c
b
a
Figure 7.
Side Panel Connectors Under the Adapter Plates
a
Remote RS-232 connector
— Connect a host device to the 3.5 mm, 3-pole captive
screw connector for serial control of the transmitter. Wire the connector as shown in
figure 8.
Do not tin the wires!
Controlling
Device
Transmit(Tx)
Receive (Rx)
Ground(G)
Transmit (Tx)
Receive (Rx)
Ground (G)
Bidirectional
G Rx Tx
REMOTE
RS-232
Figure 8.
RS-232 Wiring
Содержание XTP T FB 202
Страница 6: ...XTP T FB 202 Contents vi ...