Command
ASCII Command
(host to PowerCage)
Response
(PowerCage to host)
Additional Description
Status
General information
I
Verbose mode
0/1/2/3
Slot
X3!X3!X3!X3!•
PS
X3@X3@]
Show slot status and power
supply status.
Query firmware version
Q
Verbose mode 2/3
X8^]
Ver01*
X8^]
Query firmware build
*Q
Verbose mode 2/3
X4)]
Bld
X4)]
View the full firmware version
x.xx.xxxx
Query part number
N
Verbose mode 2/3
60-1492-01
]
Pno60-1492-01
]
Query all firmware
version
0Q
Verbose mode 2/3
X8^
-
X8&
-
X8&]
Ver00*
X8^
-
X8&
-
X8&]
Detailed status of the
enclosure firmware and any
firmware upgrade. The active
firmware is marked by an
asterisk (
*
).
???
indicates
that firmware is not loaded.
Response description:
Ethernet protocol firmware version-enclosure controller firmware version-updated firmware
version. See the response below.
Example:
0Q
1.23-1.00.0000-b000(1.81LX-PCG401-Tue,17 May 2015 19:27 UTC)-1.00.0000-b005*(1.81LX-PCG401-Wed, 27 Jul 2016 17:37 UTC)
]
X8^
X8&
X8&
KEY:
X3!
= Slot status (4 characters)
0
= Not installed,
1
= Installed, Example:
1111
= all 4 slots are installed
X3@
= Power supply status (2 characters)
0
= Failed,
1
= On,
2
= not installed
Example:
10
= power supply #1 is on and power supply #2 is failed
X4)
= Build number:
x.xx.xxxx
X8^
= Firmware version number to second decimal place (x.xx)
X8&
= Verbose firmware version-description-upload date and time.
•
= Space
Query updated FPGA
version
35Q
Verbose mode 2/3
x.xx
]
Ver35*
x.xx
View the updated loaded
FPGA version
View internal temp
E
20Stat
}
Verbose mode 2/3
X2!]
20Stat
•X2!]
KEY:
X2!
= Internal temperature in degrees Fahrenheit and Celsius:
xxx
F•
xx
C
Query model name
1I
Verbose mode 2/3
PowerCage
•
401
]
Inf01*PowerCage
•
401
]
Query model description
2I
Verbose mode 2/3
Modular
•
PowerCage
•
Enclosure
]
Inf02*Modular
•
PowerCage
•
Enclosure
]
PowerCage 401 Enclosure • SIS Configuration and Control