SIS
™
Programming and Control, cont’d
MLC 226 IP Series • SIS Programming and Control
5-14
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued)
Command
ASCII (T
elnet)
(host to switcher)
URL Encoded (W
eb)
(host to switcher)
Response
(switcher to host)
Additional description
Confi
gur
e serial port parameters
24
E
X!
*
X2%
,
X2^
,
X2&
,
X2*
CP
}
Set baud rate (
X2%
), parity (
X2^
), data bits
(
X2&
), and stop bits (
X2*
) for port
X!
.
X2%
= 300, 600, 1200, 1800, 2400, 3600, 4800,
7200, 9600, 14400, 19200, 28800, 38400, 57600,
or 1
15200 baud.
X2^
= parity (only the fi
rst letter is needed):
O
dd
E
ven
N
one (default)
M
ark
S
pace.
X2&
= data bits: 7, 8 (default = 8).
X2*
= stop bits: 1, 2 (default = 1).
W
X!
%2A
X2%
%2C
X2^
%2C
X2&
%2C
X2*
CP
|
Cpn
X!
•Ccp
X2%
,
X2^
,
X2&
,
X2*
]
Example:
E
4*9600,N,8,1CP
}
W4%2A9600%2CN%2C8%2C1CP
|
Cpn4•Ccp9600,N,8,1
]
Set the pr
ojector contr
ol port for 9600 baud,
no parity
, 8 data bits, and 1 stop bit.
V
iew serial port parameters
E
X!
CP
}
W
X!
CP
|
X2%
,
X2^
,
X2&
,
X2(
]
Confi
gur
e r
eceive timeout
24
E
X!
*
X1&
*
X2)
*
X2#
*
X2!
CE
}
Set the
time to wait
(
X1&
= waiting time in
tens of ms until r
eceipt of the fi
rst
response
character befor
e terminating the r
eceive
operation,
X2)
= waiting time in
tens of ms between characters befor
e
terminating) and
priority status
(
X2#
: 0 = default, use
send data string
command parameters; 1 = use
confi
gur
e
receive timeout
command parameters)
for
port
X!
.
X2!
= #L
or
#D (see pr
evious page).
The r
esponse includes leading zer
os.
W
X!
%2A
X1&
%2A
X2)
%2A
X2#
%2A
X2!
CE
|
Cpn
X!
•Cce
X1&
,
X2)
,
X2#
,
X2!
]
V
iew r
eceive timeout
E
X!
CE
}
W
X!
CE
|
X1&
,
X2)
,
X2#
,
X2!
]
IR/serial data port
Send an IR command
28
E
X21%
,
X5&
,
X5*
,
X5(
IR
}
Send an IR command via IR/Serial Output
port number
X21%
(1 = display port, 2 =
port
A, 3 = port B, 4 = port C).
X5&
= the IR fi
le number (0-99),
X5*
= IR
function number (1-137),
X5(
= IR playback
mode (0 = play once, 1 = play continuously).
W
X21%
%2C
X5&
%2C
X5*
%2C
X5(
IR
|
Irs
X21%
,
X5&
,
X5*
,
X5(
]
N
To stop mode 1 IR command playback (continuous playback), send the IR command again but with playback mode (
X5(
) = 0. Also, the r
esponse includes leading zer
os.
Содержание MLC 226 IP Series
Страница 30: ...Installation cont d MLC 226 IP Series Installation 2 20 PRELIMINARY ...
Страница 44: ...Operation cont d MLC 226 IP Series Operation 3 14 PRELIMINARY ...
Страница 149: ...PRELIMINARY MLC 226 IP Series B Appendix B Firmware Updates Determining the Firmware Version Updating the Main Firmware ...
Страница 158: ...Firmware Updates cont d MLC 226 IP Series Firmware Updates B 10 PRELIMINARY ...
Страница 159: ...PRELIMINARY MLC 226 IP Series C Appendix C Index ...