![Extron electronics MLC 226 IP Series Скачать руководство пользователя страница 91](http://html.mh-extra.com/html/extron-electronics/mlc-226-ip-series/mlc-226-ip-series_installation-manual_2455887091.webp)
5-13
MLC 226 IP Series • SIS Programming and Control
PRELIMINAR
Y
Command/r
esponse table for SIS commands (continued)
Command
ASCII (T
elnet)
(host to switcher)
URL Encoded (W
eb)
(host to switcher)
Response
(switcher to host)
Additional description
Serial data port confi
guration and use
These commands apply to any port that uses RS-232 communication: both 1-way (output) and 2-way (bidir
ectional) RS-232 communica
tion.
Send data string
E
X!
*
X1&
*
X2)
*
X2!
RS
}
X@
X!
= specifi
c port number (01 – 99)
1 = r
ear host (Host Contr
ol RS-232 port)
2 = front panel Confi
g port
3 =
peripheral
switcher (MLS port)
4 = display port (Pr
ojector RS-232/IR)
5 = IR/Serial port
A
6 = IR/Serial port B
7 = IR/Serial port C
X@
= command data section (< 200 bytes).
X1&
= time in tens of ms for the MLC to wait
until r
eceipt of the
fi
rst r
esponse character
befor
e terminating the curr
ent r
eceive
operation (default = 10 = 100 ms, max. =
32767). The r
esponse includes leading zer
os.
X2)
= time in tens of ms for the MLC to
wait between characters being r
eceived via
a serial port befor
e terminating the curr
ent
receive operation (default = 2 = 20 ms,
max. = 32767). The r
esponse includes
leading zer
os.
X2!
= #L
or #D. The letter parameter is case
sensitive (r
equir
es a capital “D” or capital
“L”). The r
esponse includes leading zer
os.
L =
L
ength of the message to be r
eceived.
D =
D
elimiter value.
# = byte count (for L) or a single
ASCII
character expr
essed in decimal form (for D).
Byte count # can be fr
om 0 to 32767, default
= 0. The
ASCII decimal delimiter # value
can be fr
om 0 to 00255, default = the byte
count.
Examples: A
3-byte length = 3L. A
delimiter of
ASCII 0A
= 10D.
W
X!
%2A
X1&
%2A
X2)
%2A
X2!
RS
|
X@
response fr
om command
]
N
*
X1&
*
X2)
*
X2!
is optional.
X1&
is optional only if
X2)
is also missing. If these thr
ee variables ar
e not specifi
ed,
the
default values ar
e used. For this command,
X1&
and
X2)
must both a) equal zer
o or b) be nonzer
o.
N
For W
eb encodin
g
for
X@
, convert nonalphanumeric characters to hex numbers. A
space (hex = 20) is encoded as %20.
A
plus sign (hex = 2B) is encoded as %2B.
Example:
E
05*4*7*3L
RS
}
<data>
W05%2A4%2A7%2A3L
RS
|
<data>
response fr
om command
]
N
The data string (
X@
) in this RS command is limited to 200 bytes.
0
1
2 3
4 5
6
7 8 9
10
LF
CR
20
E
s
c
30
s
p
a
ce !
“
#
$
%
&
’
40
(
)
*
+
,
-
.
/
0
1
50
2 3 4
5
6
7
8
9
:
;
60
<
=
>
?
@
A
B
C
D
E
70
F
G
H
I
J
K
L
M
N
O
80
P
Q
R
S
T
U
V
W
X
Y
90
Z
[
\
]
^
_
‘
a
b
c
100
d
e
f
g
h
i
j
k
l
m
110
n o
p
q
r
s
t
u
v
w
120
x
y
z
{
|
}
~
Del
ASCII to Decimal Conversion T
able
T
o find the decim
a
l eq
u
iv
a
lent of the A
S
CII ch
a
r
a
cter
,
a
dd
the ro
w he
a
ding
a
nd col
u
mn he
a
ding n
u
mber
s
together
.
LF = line f
eed
CR = c
a
rr
i
a
ge ret
u
rn
(
}
)
E
s
c = e
s
c
a
pe
Del = delete
Содержание MLC 226 IP Series
Страница 30: ...Installation cont d MLC 226 IP Series Installation 2 20 PRELIMINARY ...
Страница 44: ...Operation cont d MLC 226 IP Series Operation 3 14 PRELIMINARY ...
Страница 149: ...PRELIMINARY MLC 226 IP Series B Appendix B Firmware Updates Determining the Firmware Version Updating the Main Firmware ...
Страница 158: ...Firmware Updates cont d MLC 226 IP Series Firmware Updates B 10 PRELIMINARY ...
Страница 159: ...PRELIMINARY MLC 226 IP Series C Appendix C Index ...