DVS 605 • Product Configuration Software
80
EDID Minder Page
EDID Minder is an EDID management process that manages the EDID information between
the scaler and one or more input sources. Click the
EDID Minder
1
)
on the global navigation bar to open the
EDID Minder
page.
1
2
3
4
5
6
7
8
9
10
Figure 54.
EDID Minder Page
The EDID properties currently assigned to each input are displayed in the table of inputs.
The audio input format listed in an EDID is determined by the audio input format selected on
the
Input
Configuration
page.
Up to three EDID can be stored on the device as custom EDID files. Audio settings from
custom EDID files take priority over current settings on the input.
NOTE:
If an analog custom EDID file is assigned to a digital input or a digital custom
EDID file assigned to an analog input, the display may not appear correctly.
Filtering available EDID
Use the
Filter
tab (
2
)to limit the number of available EDID displayed in the
Available
EDID
and
Connected Outputs
panes.
1.
From the
Resolution
drop-down menu (
3
) select a specific resolution or
Any
.
2.
From the
Refresh Rate
drop-down menu (
4
) select a specific refresh rate or
Any
.
Assigning EDID
To assign EDID to selected inputs:
1.
From the inputs group box (table of inputs
5
) on the right, select the checkboxes for
the desired inputs
2.
From the
Favorites
,
Available EDID
, or
Connected Outputs
pane (
6
) on the left,
select the desired EDID.
3.
From the inputs group box, click the
Assign
button (
7
) to assign EDID to the selected
inputs.