DVS 605 • SIS Communication and Control
41
X12!
=
Password (Maximum length of 128 alphanumeric characters, spaces, and symbols.
Cannot start with a space.)
NOTES:
•
A user password cannot be assigned if no administrator password exists, the
E14
error code is returned. If the administrator password is cleared, the user
password is also removed.
•
Password characters are replaced with asterisks (*) for security purposes, when
querying for a password.
•
The factory configured passwords for all accounts on this device have been
set to the device serial number. In the event of a complete system reset, the
passwords convert to the default, which is no password.
X12%
=
Connections security level:
11
= User
12
= Administrator
X12&
=
The number of seconds before timeout on the IP connection: min. =
1
,
max. =
65000
, (default =
30
=
300
seconds). If no data is received during the timeout
period, the Ethernet connection is closed. Each step =
10
seconds. Applicable only
when connected via Ethernet. When the scaler is connected via RS-232, only the global
timeout commands apply (returns
E13
). Response is returned with leading zeros.
X13!
=
Firmware Query (‘Q’ commands)
*Q
= Firmware and build number [<
x.xx.xxxx
> ]
0Q
= Verbose version information (
2Q
-
3Q
-
4Q
) sum of responses from
2Q-3Q-4Q
1Q
= Firmware version (
<currently running code> x.xxx
)
2Q
= Final stage bootloader (Uboot) version (
x.xxx
)
3Q
= Factory base code version (
<factory
base
code x.xxx>*<kernel
version
x.xxx)
–
description
–
date
loaded>
)
4Q
= Updated firmware version (
<
updated
code
version
x.xxx*<kernel
version
x.xxx – description
–
date
loaded
>
)
NOTE:
For
3Q
and
4Q
, an asterisk ‘
*
’ after version number indicates which version
is currently running. Question marks
?.??
indicates that only the factory firmware
version is loaded. A caret (
^
) indicates the firmware version that should be running,
but a Mode 1 reset was executed and the default factory firmware version is
loaded. An exclamation point (
!
) indicates corrupted firmware.
Example:
1.03*(1.42-DVS 605 -Thur, 21 Apr 2012 22:30:57 GMT)
.
The SIS Command and Response tables start on the next page.
Содержание DVS 605