DMP 64 Plus • SIS Configuration and Control
49
Command
ASCII command
(host to device)
Response
(device to host)
Additional description
Digital I/O
Get input status
EX3@
GPIT
}
X3#
*
X3$]
Get output status
EX3@
*
X3%
GPOT
}
X3^
*
X3&]
Get state for input
EX3@
GPI
}
Gpi
X3@
*
X3!]
KEY:
X3!
= Digital Input Status:
0
= Logic low
1
= Logic high
X3@
= Digital I/O Channel:
1
through
6
X3#
= Action Type:
0
= No action/off
Mutes
1
= Level trigger (low mutes)
2
= Level trigger (high mutes)
3
= Edge trigger (high to low mutes, low to high unmutes)
4
= Edge trigger (high to low unmutes, low to high mutes)
5
= Toggle trigger (high to low toggles mute)
6
= Toggle trigger (low to high toggles mute)
Group Mutes
7
= Level trigger (low mutes)
8
= Level trigger (high mutes)
9
= Edge trigger (high to low mutes, low to high unmutes)
10
= Edge trigger (high to low unmutes, low to high mutes)
11
= Toggle trigger (high to low toggles mute)
12
= Toggle trigger (low to high toggles mute)
Macros
13
= Edge trigger (high to low starts macro)
14
= Edge trigger (low to high starts macro)
Presets
15
= Edge trigger (high to low recalls preset)
16
= Edge trigger (low to high recalls preset)
X3$
= Various according to action type:
Mutes
— Input number for muting. If
X3#
is not specified, muting matches the input with the
corresponding I/O channel number.
Group Mutes
—Group member for muting. If
X3#
is not specified, muting matches the group
with the corresponding I/O channel number.
Macros
— Macro number. If
X3#
is not specified, the macro number defaults to the
corresponding I/O channel number.
Presets
— Preset number. If
X3#
is not provided, the preset number defaults to the
corresponding I/O channel number.
X3%
= Digital Output:
1
X3^
= Output Mode:
0
= Output always high
1
= Output always low
Mutes
2
= Mute high
3
= Unmute high
Group Mutes
4
= Group mute high
5
= Group unmute high
Macros
6
= Macro started set high once (blink)
7
= Macro started set low once (blink)
Presets
8
= Preset recalled set high once (blink)
9
= Preset recalled set low once (blink)
Automix Gate Status
10
= Automix gate on (>1024) set high
11
= Automix gate on (>1024) set low
Signal Presence
12
= Signal presence (>-40 dBFS) set high
13
= Signal presence (>-40 dBFS) set low
X3&
= Various according to output mode:
Mutes
— Input number for monitoring. If
X3^
is not specified, monitoring defaults to the input
with the corresponding I/O channel number.
Group Mutes
—Group member for monitoring. If
X3^
is not specified, the macro number
defaults to the corresponding I/O channel number.
Macros
— Macro number. If
X3^
is not specified, the macro number defaults to the
corresponding I/O channel number.
Presets
— Preset number. If
X3^
is not provided, the preset number defaults to the
corresponding I/O channel number.
Automix Gate Status
— Input number for automix gate monitoring. If
X3^
is not specified,
the number defaults to the corresponding I/O channel number.
Signal Presence
— Input number for signal presence monitoring. If
X3^
is not specified, the