Installation Site Requirements
If you plan to cable your SSA switch with SFP+ pluggable transceivers, you might need to have 7.5 cm
to 10 cm (3 to 4 in.) of clearance on the switch I/O port side of the SSA switch.
See
Environmental Guidelines for ExtremeSwitching Products
for environmental guidelines relating to
the installation.
The installation site must be within reach of the network cabling and must meet the following
requirements:
•
Appropriate grounded power receptacles must be located within 2 m (7 ft) of the site.
•
A temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation site
with fluctuations of less than 10°C (18°F) per hour.
Caution
To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1
cm (2.0 in.) at the front and rear of the device.
Precaución: Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje
un espacio mìnimo de 5.1 cm (2 pulgadas) con respecto el anverso y reverso del aparato.
Warning
Before rack-mounting the device, ensure that the rack can support it without compromising
stability. Otherwise, personal injury and/or equipment damage may result.
Advertencia: Antes de montar el equipo en el rack, asegurarse que el rack puede soportar su
peso sin comprometer su propia estabilidad, de otra forma, daño personal o del equipo puede
ocurrir.
Warnhinweis: Überzeugen Sie sich vor dem Einbau des Gerätes in das Rack von dessen
Stabilität, ansonsten könnten Personenschäden oder Schäden am Gerät die Folge sein.
Avertissements: Avant de monter l'appareil sur le bâti, assurez-vous que l'étagère peut en
supporter le poids sans en compromettre la stabilité. Cela pourrait, dans le cas contraire,
entraîner des blessures ou des dommages au matériel.
For more information about flat surface installation or rack installation using the mounting brackets
installed on the SSA switch, see
Contents of the Mounting Kit
lists the contents of the SSA-FB-MOUNTKIT mounting kit.
Table 23: Contents of SSA-FB-MOUNTKIT
Item
Quantity
Left and right rails and extensions assemblies
2
Adapter plates
2
Mid-Brackets
2
6-32 flat head screws
6
Optional Rack Mount Rail Kit Installation
S-Series Stand Alone (SSA) Switch Hardware Installation Guide
53