Table 12: System LEDs (continued)
LED
Color
State
Recommended Action
Blue
Blinking: Virtual Switch Bonding is enabled, but
the devices are not bonded
None
Solid: Virtual Switch Bonding is enabled, and the
devices are bonded.
None
PWR
Off
The SSA switch is not receiving power from the
power supplies.
Ensure that the power cords are
plugged in and that power is
available at the source.
for technical support.
Green
Functional. Indicates one of the following
conditions:
•
A single power supply is present and
operating normally.
•
Two power supplies are present and operating
normally.
None
Amber
One of the following conditions has occurred:
•
Two power supplies are present but only one
is operating normally while the other is not
connected.
•
Two power supplies are present but only one
is operating normally while the other indicates
a fault.
•
Both power supplies are faulty but the SSA
switch is still receiving power.
•
Power supplies are operating in additive (non-
redundant) mode.
•
Other internal fault.
Ensure that the power cords are
plugged in and that power is
available at the source.
for technical support.
Note
The PWR LED status indication is based on power supplies being powered on.
describes the CPU LED when the SSA switch is in a virtual switch bonding configuration.
Table 13: CPU LED in Virtual Switch Bonding (VSB) Configuration
Color
State
Green and Blue
Blinking: Image has started and found chassis bonding enabled.
Blue
Solid: Functional: binding is operational and ready to switch.
Blue
Blinking: Binding is not functional (non-operational).
Power Supply LED
The SSA-FB-AC-PS-A and SSA-FB-AC-PS-B power supplies have a single LED.
different states of the power supply LED.
Troubleshooting
S-Series Stand Alone (SSA) Switch Hardware Installation Guide
37