TABLE 11
Initial setup and configuration checklist (continued)
Task
Task details or additional information
•
The following commands can be useful to establish an operational baseline for the
device. Refer to
Extreme SLX-OS Monitoring Configuration Guide
for the SLX
9030/9030-T device for more information about these commands.
–
show chassis
–
show system
–
show slots
–
show linecard
–
show environment fan
–
show environment power
–
show environment sensor
–
show environment temp
Back up the configuration.
Use the
copy running-config
command to copy the running configuration to the startup
configuration. Refer to
on page 62 for more information about
this command.
Items required
The following items are required for initial setup and verification of the device:
•
The device, mounted and installed with the required interface modules, FRUs, transceivers, and cables, and connected to a
power source.
•
A workstation computer with an installed terminal emulator application, such as HyperTerminal for Windows.
•
An unused IP address with corresponding subnet mask and gateway address.
•
A serial cable (provided) with an RJ-45 connector.
•
Two Ethernet cables (one per management module).
•
Optional: Access to an FTP server or USB device for backing up (uploading) or downloading the device configuration or
collecting diagnostic output data.
•
Optional: An Extreme USB drive for backing up (uploading) or downloading the device configuration or collecting diagnostic
output data.
Providing power to the device
After you complete the physical installation, you can power on the system.
1. Install alternating-current (AC) or direct-current (DC) power supplies in the switch. Refer to
of the guide.
2. Connect AC or DC power cables to the power supply connectors on the rear panel.
NOTE
The equipment should be installed near a power source and in an easily accessible location.
3. Connect the power cables to the 100-240 VAC or 48-60 VDC power source. The power sources should be on separate
circuits to protect against power failure. Ensure that the power cords have a minimum service loop of 6 inches available and are
routed to avoid stress.
Items required
ExtremeSwitching SLX 9030 Hardware Installation Guide
56
9035691-02 Rev AD
Содержание EN-SLX-9030-48S-4C
Страница 6: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 6 9035691 02 Rev AD...
Страница 10: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 10 9035691 02 Rev AD...
Страница 64: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 64 9035691 02 Rev AD...
Страница 76: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 76 9035691 02 Rev AD...
Страница 82: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 82 9035691 02 Rev AD...
Страница 96: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 96 9035691 02 Rev AD...