5. Open a terminal emulator application (such as HyperTerminal on a PC, or TERM, Tip, or Kermit in a UNIX environment), and
configure the application as follows:
•
In a Windows environment:
Parameter
Value
Bits per second
115200
Data bits
8
Parity
None
Stop bits
1
Flow control
None
NOTE
Flow control is not supported on the serial consoles when attached to remote terminal servers and must be
disabled to ensure proper operation.
•
In a UNIX environment, enter the following string at the prompt:
tip /dev/ttyb -115200
If ttyb is already in use, use ttya instead and enter the following string at the prompt:
tip /dev/ttya -115200
When the terminal emulator application stops reporting information, press
Enter
. You receive the following login prompt:
SLX login:
6. Log in to the console using
admin
as the default login name and
password
as the default password.
As login to the device occurs, you are prompted to change the device passwords.
Please change passwords for switch default accounts now.
Use Control-C to exit or press 'Enter' key to proceed.
7. Press
Enter
to step through a procedure to change the passwords as shown in the following example. To skip modifying the
password, press
Ctrl+C
.
Warning: Access to the Root and Factory accounts may be
required for proper support of the switch. Please ensure the Root
and Factory passwords are documented in a secure location. Recovery of
a lost Root or Factory password will result in fabric downtime.
for user - admin
Changing password for admin
Enter old password:
Enter new password:
Re-type new password:
passwd: all authentication tokens updated successfully
Passwords can be 8 through 40 characters long. They must begin with an alphabetic character. They can include numeric
characters, the period (.), and the underscore (_) only. Passwords are case-sensitive, and they are not displayed when you enter
them on the command line. For more information on passwords, refer to
Extreme SLX-OS Security Configuration Guide
for the
SLX 9030/9030-T device.
Establishing a serial connection
ExtremeSwitching SLX 9030 Hardware Installation Guide
58
9035691-02 Rev AD
Содержание EN-SLX-9030-48S-4C
Страница 6: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 6 9035691 02 Rev AD...
Страница 10: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 10 9035691 02 Rev AD...
Страница 64: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 64 9035691 02 Rev AD...
Страница 76: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 76 9035691 02 Rev AD...
Страница 82: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 82 9035691 02 Rev AD...
Страница 96: ...ExtremeSwitching SLX 9030 Hardware Installation Guide 96 9035691 02 Rev AD...