BlackDiamond 8000 Series Modules
BlackDiamond 8800 Series Switches Hardware Installation Guide
24
The 8500-MSM24, MSM-48c and 8900-MSM128 modules have a slot for one of the following option
cards:
●
S-G8Xc—Adds eight 1-gigabit SFP data ports to the MSM. These data ports operate the same as the
ports on the G24Xc I/O module. (See
“G24Xc I/O Module” on page 40
for more information.)
●
S-10G1Xc—Adds one 10-gigabit XFP data port to the MSM. This data port operates the same as the
ports on the 10G4Xc I/O module. (See
“10G4Xc I/O Module” on page 38
for more information.)
Different MSM models have different memory and processing capacity. For details of feature support in
the MSMs, see the
ExtremeXOS Concepts Guide
.
NOTE
See the
ExtremeXOS Concepts Guide
and the
ExtremeXOS Command Reference Guide
for more information about
numbering conventions for the modules and ports, as well as configuration and display information.
MSM LEDs
Table 8
describes the LED activity on the BlackDiamond 8000 series MSMs.
NOTE
The LEDs on the management Ethernet port are not labeled. On the MSM-G8X and MSM-48 modules, the LED on
the right is the link LED, and the one on the left is the activity LED. On other MSMs, the left LED indicates link
status, and the right LED indicates link activity by blinking green.
NOTE
The data port LEDs on the MSM-G8X operate the same as the port status LEDs on the G24X I/O module.
Table 8: 8500-MSM24,
MSM-G8X, MSM-48. MSM-48c, and 8900-MSM128 LEDs
LED
Color
Indicates
ERR
Amber
A critical software error has been logged since power-up.
Off
Normal operation is occurring.
ENV
Green
Environment (temperature, fan, power supply) is operating properly.
Amber
Environmental failure has occurred.
MSTR
or
MSTR/DIAG
Green
Module is operating as primary MSM.
Amber
Module is operating as backup (secondary) MSM.
Green blinking
Power-on self-test (POST) is running.
Off
Normal operation for diagnostics.
SYS
or
SYS/STA
Green blinking
Normal operation is occurring.
Amber blinking
Diagnostic tests are running on the module.
The LED resets if the diagnostics are terminated. The LED returns
to flashing amber if another diagnostic test is started.
Amber
Diagnostic failure has occurred.
Off
Switch is not receiving power.
Link on MSTR
Ethernet port
Green
Link is up.
Off
Link is down.
Activity on MSTR
Amber
Packet activity is occurring.
Содержание BlackDiamond 8806
Страница 8: ...Contents BlackDiamond 8800 Series Switches Hardware Installation Guide 8...
Страница 11: ...1 About the BlackDiamond 8800 Series Switches...
Страница 12: ......
Страница 63: ...2 Installing BlackDiamond 8800 Series Hardware...
Страница 64: ......
Страница 125: ...3 Installing BlackDiamond Switch Accessories...
Страница 126: ......
Страница 149: ...BlackDiamond 8800 Series Switches Hardware Installation Guide 149 4 BlackDiamond Maintenance Procedures...
Страница 150: ...BlackDiamond 8800 Series Switches Hardware Installation Guide 150...
Страница 158: ...Replacing BlackDiamond 8800 Series Chassis Components BlackDiamond 8800 Series Switches Hardware Installation Guide 158...
Страница 167: ...5 Appendices...
Страница 168: ......
Страница 192: ...Technical Specifications BlackDiamond 8800 Series Switches Hardware Installation Guide 192...
Страница 200: ...Index BlackDiamond 8800 Series Switches Hardware Installation Guide 200...