background image

Index

 

BlackDiamond 8800 Series Switches Hardware Installation Guide

198

chassis spacing, 68
grounding, 70
humidity, 68
space, 71

reset button, MSM, 23
RF interference

patch panel installation, 75
preventing, 77
problems caused by, 77

RJ-45 cable, 73
RJ-45 connector jackets, 73
running cable. 

See 

cable, installing

S

S-10G1Xc option card

features, 24
installing, 130
weight, 186

safety requirements, 169

See also

 environmental requirements

safety standards, 181, 183
securing rack to floor, 71
serial number

BlackDiamond 8806 switch, 16
BlackDiamond 8810 switch, 18

service access to the rack, 71
S-G8Xc option card

features, 24
installing, 130
weight, 186

shipping indicators, BlackDiamond 8810, 85
shock watch indicator, 85
site planning process, 65
slack, cable, 75
slot assignments, 109, 110
space requirements, rack, 71
specifications

1200 W DC PSU, 189
600/900 W AC PSU, 188
700/1200 W AC PSU, 188
BlackDiamond 8806 switch, 183
BlackDiamond 8810 switch, 181
modules, 185
option cards, 186

S-POE daughter card, 26

I/O module compatibility, 37, 44
installation, 127
weight, 187

standards

cabling, 72, 80
commercial building, 80
grounding, 80
rack, 70

storage conditions, 182, 185
support bracket, 90
switch configuration, saving, 21
switch spacing requirements, 68
system dump, 23

T

technical specifications

1200 W DC PSU, 189
600/900 W AC PSU, 188
700/1200 W AC PSU, 188
BlackDiamond 8806 switch, 183
BlackDiamond 8810 switch, 181
modules, 185
option cards, 186

telecom standards, 182, 184
temperature, wiring closet, 67
text conventions, 10
tilt watch indicator, 85
tools, installation

AC power cord retainer, 133, 136
AC PSU, 101
blank front panel, 118
chassis, 88
DC PSU, 104
external memory card, 121
fan tray, 151
MSM option card, 130
PSU cover, 139
PSU/fan controller, 154
S-POE daughter card, 127

transition time, UPS, 79, 80
transportation conditions, 182, 185
troubleshooting

external memory card, installing, 121
over-current conditions, 56, 58
power, turning off, 56, 58
RF interference, 77

U

uninterruptible power supply. 

See

 UPS

unshielded twisted pair. 

See 

UTP

UPS

amperage requirements, calculating, 80
description, 79
features, 79
selecting, 79
size, determining, 80
transition time, 79, 80

UTP cable

bend radius, 75
category 5, 75

Содержание BlackDiamond 8806

Страница 1: ...ta Clara California 95051 888 257 3000 408 579 2800 http www extremenetworks com BlackDiamond 8800 Series Switches Hardware Installation Guide BlackDiamond 8806 Switch BlackDiamond 8810 Switch Publish...

Страница 2: ...SummitStack Triumph Unified Access Architecture Unified Access RF Manager UniStack the Extreme Networks logo the Alpine logo the BlackDiamond logo the Extreme Turbodrive logo the Summit logos and the...

Страница 3: ...the BlackDiamond 8000 Series Modules 19 Management Switch Modules MSM 21 Redundant MSM Activity 21 MSM Physical Features 22 MSM LEDs 24 I O Modules 25 BlackDiamond 8500 Series I O Modules 26 8500 G48...

Страница 4: ...Specifications 56 Extreme Networks 600 900 W AC PSU 57 Minimum Software Required 57 LEDs 58 Power Supply Cords 58 Fuse 58 Specifications 59 Combining Different AC PSU Models 59 Extreme Networks 1200 W...

Страница 5: ...d Mount Brackets 89 Rack Mounting the BlackDiamond 8800 Series Chassis 90 Grounding the BlackDiamond 8800 Series Chassis 93 Initial Management Access 95 Chapter 6 Installing Power Supply Units in the...

Страница 6: ...S POE Card 129 Installing an Option Card in the 8500 MSM24 MSM 48c or 8900 MSM128 130 Removing an MSM Option Card 132 Chapter 9 BlackDiamond AC Power Cord Retainers 133 BlackDiamond 8810 AC Power Cord...

Страница 7: ...t 160 Repacking the BlackDiamond 8810 Chassis 160 Repacking the BlackDiamond 8806 Chassis 164 Part 5 Appendices Appendix A Safety Information 169 Considerations Before Installing 169 Installing Power...

Страница 8: ...Contents BlackDiamond 8800 Series Switches Hardware Installation Guide 8...

Страница 9: ...switch differs from the information in this guide follow the installation note or release note Intended Audience This guide is intended for use by network administrators responsible for installing an...

Страница 10: ...the Extreme Networks website at the following location http www extremenetworks com go documentation You can select and download the following Extreme Networks documentation from the Documentation Ov...

Страница 11: ...1 About the BlackDiamond 8800 Series Switches...

Страница 12: ......

Страница 13: ...abit Ethernet copper ports 10 100 1000 and Gigabit Ethernet fiber ports SFP or 10 Gigabit Ethernet ports SFP or XFP Management Switch Fabric Modules MSMs that provide the active switching fabric and C...

Страница 14: ...lex mode in accordance with technical standards Management Ports Each BlackDiamond management switch fabric module MSM has a 10 100BASE TX Ethernet management port This port allows you to communicate...

Страница 15: ...wer supply bay that accommodates up to six power supplies accessed from the front of the unit One fan tray accessed from the front right of the unit One connector for an ESD preventive wrist strap Dep...

Страница 16: ...s with backplane Eight dedicated I O module slots labeled 1 2 3 4 7 8 9 and 10 One dedicated MSM slot labeled 5 A One dual use slot for an I O module or MSM labeled 6 B Certain restrictions apply to t...

Страница 17: ...ee I O modules Figure 3 Front of the BlackDiamond 8810 Chassis Figure 2 shows the rear panel of the BlackDiamond 8810 chassis Figure 4 Rear Panel of the BlackDiamond 8810 Chassis ASP042 ESD wrist stra...

Страница 18: ...s Switches Hardware Installation Guide 18 The rear panel of the BlackDiamond 8810 chassis provides Chassis serial number Ethernet MAC address of the switch Symbols of safety certification Access to th...

Страница 19: ...carrier also includes ejector injector levers and captive retaining screws at each end of the module front panel LEDs on the module front panel provide information about the operating status of the m...

Страница 20: ...00 c series I O Yes Yes Yes Yes Yes Yes 8800 e series I O Yes Yes Yes Yes Yes Yes Table 6 BlackDiamond 8000 Series Module Compatibility 8800 Series with 8500 Series 8800 Series Modules 8500 Series Mod...

Страница 21: ...MSM operates as the primary MSM and the other becomes the backup secondary MSM The primary MSM is responsible for upper layer protocol processing and system management functions Packet handling is dis...

Страница 22: ...MSM24 Figure 6 shows the MSM G8X Figure 6 MSM G8X Figure 7 shows the MSM 48 Figure 7 MSM 48 Module status LEDs Compact flash Console port MGMT port A R D BD_229 Module status LEDs SYS STA MSTR DIAG ER...

Страница 23: ...lternate BootROM image you must hold the A button while pressing the R button simultaneously D button Allows you to force a system dump that dumps the debug information into NVRAM This information is...

Страница 24: ...On the MSM G8X and MSM 48 modules the LED on the right is the link LED and the one on the left is the activity LED On other MSMs the left LED indicates link status and the right LED indicates link act...

Страница 25: ...ration for the I O module is not preserved unless you explicitly save the configuration to NVRAM You can configure parameters of an I O module after it is installed or preconfigure a slot for a certai...

Страница 26: ...e I O module Figure 10 has 48 autosensing 10 100 1000BASE T ports that use standard RJ 45 connectors Figure 10 8500 G48T e I O Module You can add an optional S POE daughter card to the 8500 G48T e I O...

Страница 27: ...iguration of the 8500 G48T e I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The 8500 G24X e I O module h...

Страница 28: ...amond 8800 original series I O modules G24X I O Module The G24X I O module Figure 12 has 24 unpopulated SFP based Gigabit Ethernet ports Figure 12 G24X I O Module In the default configuration of the G...

Страница 29: ...gure 13 10G4X I O Module In the default configuration of the 10G4X I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type a...

Страница 30: ...e default configuration of the G48T I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid Operate in autonegoti...

Страница 31: ...following functions Enables the port for discovery classification and power delivery Enforces port power limits by denying power to a device exceeding the configured limit Enforces class limits by de...

Страница 32: ...dules If you attempt to install one of these I O modules before upgrading the software on your MSM the module will not be recognized by the software and it will not power up The following error messag...

Страница 33: ...uration of the G48Ta I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid Operate in autonegotiation mode The...

Страница 34: ...ule all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The G48Xa module has the following LEDs Module status Module dia...

Страница 35: ...LAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The 10G4Xa I O module has the following LEDs Module status Module diagnostics Port status For informatio...

Страница 36: ...Modules The BlackDiamond 8800 c series of I O modules consists of the following G48Tc I O Module on page 37 10G4Xc I O Module on page 38 10G8Xc I O Module on page 39 G24Xc I O Module on page 40 G48Xc...

Страница 37: ...an attached device as well as the usual Ethernet connection using a single cable The G48Tc I O module supports the IEEE 802 3af PoE specification In the default configuration of the G48Tc I O module...

Страница 38: ...ult configuration of the 10G4Xc I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The 10G4Xc I O module has...

Страница 39: ...fault configuration of the 10G8Xc I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The 10G8Xc I O module h...

Страница 40: ...e In the default configuration of the G24Xc I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The G24Xc I O...

Страница 41: ...configuration of the G48Xc I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The G48Xc I O module has the...

Страница 42: ...Samples represent an unrecognized module in slot 2 Console ERROR Unknown cardtype in slot 2 please program the eeprom Log Error HAL Card Error MSM A Unable to read cardtype for slot 2 G48Te I O Module...

Страница 43: ...scovered and classified as 802 3af compliant or as legacy devices ExtremeXOS implements the following functions Enables the port for discovery classification and power delivery Enforces port power lim...

Страница 44: ...thernet PoE to an attached device in addition to the usual Ethernet connection using a single cable The G48Te2 I O module supports the IEEE 802 3af PoE specification In the default configuration of th...

Страница 45: ...he messages that may be displayed on the console or in the log Samples represent an unrecognized module in slot 2 Console ERROR Unknown cardtype in slot 2 please program the eeprom Log Error HAL Card...

Страница 46: ...two port groups are displayed by the port LEDs The 8900 G96T c I O module has the following LEDs Module status Module diagnostics Port status For information about the LEDs and their activity on the...

Страница 47: ...t configuration of the 8900 10G24X c I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid The 8900 10G24X c I...

Страница 48: ...Module In the default configuration of the 8900 10G8X xl I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid...

Страница 49: ...on of the 8900 G48T xl I O module all ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid Operate in autonegotiation mode Th...

Страница 50: ...ample protocol type and VLANid The 8900 G48X xl I O module has the following LEDs Module status Module diagnostics Port status For information about the LEDs and their activity on the 8900 G48X xl I O...

Страница 51: ...nt The optional PoE card is installed on the module This LED is present only on the G48Tc G48Te2 8500 G48T e and 8900 G48T xl modules Status Green blinking Normal operation Amber blinking Configuratio...

Страница 52: ...Tc I O module with an installed S POE card G48Te2 I O module with an installed S POE card 8500 G48T e I O module with an installed S POE card 8900 G48T xl I O module with an installed S POE card Port...

Страница 53: ...n N N configuration each group of power supplies can provide A B feed redundancy for the system After the system is properly configured if one PSU fails the others will provide sufficient power to ope...

Страница 54: ...on the PSU and exhaust the air through the rear vents of the switch Airflow through the PSU is independent from the airflow through the rest of the switch The AC input connection is located on the swi...

Страница 55: ...ting Power Supply Cords on page 172 Fuse The Extreme Networks 700 1200 W AC PSU line and neutral legs are both fused Power to the switch may still be live if the neutral fuse is open This is not a fie...

Страница 56: ...ore installed PSUs are needed to support the load if the low line power range is used to power the switch The software determines the maximum available power required for the switch and enables the mo...

Страница 57: ...orks 600 900 W AC PSU can be used in combination with an Extreme Networks 700W 1200W AC PSU in the same BlackDiamond 8806 system Extreme Networks does not recommend using the 600W 900W AC PSU in combi...

Страница 58: ...nect power to the 600 900 W AC PSU Make sure that this connection is easily accessible Make sure that the 600 900 W AC PSU circuit is not overloaded Use proper over current protection such as a circui...

Страница 59: ...voiding the possibility of over current by deciding whether to budget down PSUs with 220 V AC inputs when PSUs with 110 V AC inputs are present or to keep 110 V AC PSUs disabled CAUTION Even though th...

Страница 60: ...t vents on the 1200 W DC PSU and exits to the rear vents of the switch Airflow through the 1200 W DC PSU is independent of the airflow that exists through the rest of the switch The input DC cable has...

Страница 61: ...any reason the PSU does not contain user serviceable parts In the event of failure return the defective 1200 W DC PSU to Extreme Networks for repair or replacement Minimum Software Required The MSM in...

Страница 62: ...Power Supply Units for BlackDiamond 8800 Series Switches BlackDiamond 8800 Series Switches Hardware Installation Guide 62...

Страница 63: ...2 Installing BlackDiamond 8800 Series Hardware...

Страница 64: ......

Страница 65: ...ety information provided in Appendix A of this guide Planning Your Site By carefully planning your site you can maximize the performance of your existing network and ensure that it is ready to migrate...

Страница 66: ...ordinances and codes on wiring specifications The NEC classification is published by the National Fire Protection Association NFPA The address is NFPA 1 Batterymarch Park Quincy Massachusetts 02169 U...

Страница 67: ...ature and humidity NOTE Extreme Networks recommends that you consult an electrical contractor for commercial building and wiring specifications Temperature Extreme Networks equipment generates a signi...

Страница 68: ...djacent BlackDiamond switches A patch panel does not require any power and does not generate any heat NOTE Up to five adjacent switches will continue to function without safety concerns However produc...

Страница 69: ...thetic resins from the wiring closet Check the appropriateness of floor mats and flooring Connect metal chassis conduit and other metals to ground using dedicated grounding lines Use electrostatically...

Страница 70: ...table building ground All Extreme Networks switches are designed with mounting brackets that provide solid metal to metal connection to the rack If you do not use equipment racks you can attach wiring...

Страница 71: ...uirements for the Rack Provide enough space in front of and behind the switch so that you can service it easily Allow a minimum of 48 inches 122 cm in front of the rack and 24 inches 61 cm behind the...

Страница 72: ...ning and installing a network Maintaining accurate records helps you to Relocate devices easily Make changes quickly Isolate faults in the distribution system Locate the opposite end of any cable Know...

Страница 73: ...of connector jacket types that are not recommended as well as those that are recommended Table 17 Media Types and Maximum Distances Standard Media Type Mhz Km Rating Maximum Distance Meters 1000BASE...

Страница 74: ...ables and patch panels MRJ21 to MRJ21 cable such as the AMP NETCONNECT part number 1499515 X Figure 41 MRJ21 to RJ 45 octopus cable such as the AMP NETCONNECT part number 1499520 X Figure 41 MRJ21 to...

Страница 75: ...If you build your own cable be sure that cable is properly crimped When installing a patch panel using twisted pair wiring untwist no more than 1 inch 2 54 cm of the cable to avoid radio frequency RF...

Страница 76: ...ommend that the bend radius for fiber optic cable equal 2 inches 5 08 cm minimum for each 90 degree turn as shown in Figure 43 NOTE Kinks and sharp bends can destroy or impair the cable s ability to c...

Страница 77: ...or loss of communication To prevent RF interference avoid the following situations Attaching UTP cable to AC power cables Routing UTP cable near antennas such as an amateur radio antenna Routing UTP...

Страница 78: ...equipment do not make this connection through an extension cord or power strip If your switch includes more than one power supply connect each power supply to different independent power sources If a...

Страница 79: ...l outlet and a device such as a switch to prevent outages sags surges and bad harmonics from adversely affecting the performance of the device A UPS traditionally can perform the following functions A...

Страница 80: ...determine the minimum volt amperage requirements for your UPS we recommend that you add 30 to the total UPS Transition Time Transition time is the time that is necessary for the UPS to transfer from...

Страница 81: ...nstall the following BlackDiamond chassis models BlackDiamond 8806 chassis BlackDiamond 8810 chassis The BlackDiamond 8800 series chassis fits into a standard 19 inch 48 26 cm rack You can install the...

Страница 82: ...ton 2 Open the top flaps and remove the accessories and documentation pack from the shipping carton see Figure 44 Lift out the packing foam Figure 44 Removing Accessories from the BlackDiamond 8806 Ch...

Страница 83: ...Chassis Shipping Carton 4 Slide the shipping carton up over the BlackDiamond 8806 chassis see Figure 46 Figure 46 Removing the Carton from the BlackDiamond 8806 Chassis 5 Unwrap the chassis EX_111A C...

Страница 84: ...ckDiamond 8806 Chassis CAUTION Do not use the fan tray handle to lift or maneuver the BlackDiamond 8806 chassis This handle is not designed to support the weight of the chassis Verify that the followi...

Страница 85: ...ors display a white state as shown in Figure 48 Figure 48 Tilt Watch and Shock Watch Indicators CAUTION Do not proceed with unpacking the chassis if either the Tilt Watch indicator or the Shock Watch...

Страница 86: ...he prongs inward applying equal pressure on each side c Pull the prongs outward until the clip lock is released from the carton Repeat these steps to release each remaining clip lock Figure 50 Clip Lo...

Страница 87: ...hand hold on the back panel of the BlackDiamond 8810 chassis see Figure 47 CAUTION Do not use the fan tray handle to lift or maneuver the BlackDiamond 8810 chassis This handle is not designed to suppo...

Страница 88: ...e Networks Inc Pre installation Requirements The following tools equipment and resources are required for installing the BlackDiamond 8800 series chassis ESD preventive wrist strap provided 19 inch su...

Страница 89: ...o attach the mid mount brackets 1 Set the empty chassis in an upright position on a secure flat surface 2 Determine the locations for the mid mount brackets NOTE Each side of the chassis has two sets...

Страница 90: ...s To mount the BlackDiamond 8800 series chassis in a rack 1 Locate the 19 inch support bracket that is shipped with the BlackDiamond 8800 series chassis 2 Identify the rack location where the chassis...

Страница 91: ...ing brackets are flush against the rack uprights 6 Secure the chassis to the system rack using eight rack mounting screws Screws are not provided Be sure that the screws are secure Refer to Figure 56...

Страница 92: ...Installing the BlackDiamond 8800 Series Chassis BlackDiamond 8800 Series Switches Hardware Installation Guide 92 Figure 56 Securing the BlackDiamond 8806 Chassis to a Rack EX_171A...

Страница 93: ...ed A grounding point with integrated pem nuts is provided on the back of the chassis You need the following materials to ground the chassis Two 10 24 screws One copper standard barrel 2 hole compressi...

Страница 94: ...ng point on the back of the chassis Figure 58 and Figure 59 Figure 58 Back of BlackDiamond 8806 Chassis Figure 59 Back of BlackDiamond 8810 Chassis 2 Strip 0 5 inch 1 2 cm of insulation from the stran...

Страница 95: ...cable according to the manufacturer s specifications 5 Insert the screws through the lug and into the grounding point on the back of the chassis 6 Connect the other end of the wire to a known reliabl...

Страница 96: ...Installing the BlackDiamond 8800 Series Chassis BlackDiamond 8800 Series Switches Hardware Installation Guide 96...

Страница 97: ...our network Read the latest installation and safety information provided in this chapter and in Appendix A Safety Information See Appendix A Safety Information for additional information regarding reg...

Страница 98: ...ts the BlackDiamond 8800 series switches and their compatible power supply units Combining Different AC PSU Models When 600 900 W AC PSUs and 700 1200 W AC PSUs are combined in the same BlackDiamond 8...

Страница 99: ...in the same BlackDiamond switch Minimum Software Requirements The Extreme Networks PSUs have the following minimum software requirements 600 900 W AC PSU For the system to recognize a 600 900 W AC PSU...

Страница 100: ...supply bay in the BlackDiamond 8800 series switch can accommodate up to six hot swappable AC PSUs NOTE In a BlackDiamond 8806 system the Extreme Networks 700W 1200 W AC PSU can be combined with an Ext...

Страница 101: ...moval Installing the PSU CAUTION Make sure that the AC PSU circuit is not overloaded Use proper over current protection such as a circuit breaker to prevent over current conditions To install an Extre...

Страница 102: ...nnect the AC power supply cord a If necessary remove the power cord retainer as described in Chapter 3 BlackDiamond AC Power Cord Retainers b Connect the new AC power cord to the AC input on the front...

Страница 103: ...necting a BlackDiamond 8810 AC Power Cord on page 135 or Removing the BlackDiamond 8806 AC Power Cord Retainer on page 138 b Completely disconnect and remove the old power cord c Connect the new AC po...

Страница 104: ...gure 62 You must use this cable with the DC PSU This section provides information about DC power specifications to be used in connecting the DC cable to the DC source voltage Wiring the DC power cord...

Страница 105: ...ce The green yellow termination ground must connect to the same earth ground point as the switch Installing a 1200 W DC PSU To install an Extreme Networks 1200 W DC PSU 1 Attach an ESD preventive wris...

Страница 106: ...talling the 1200 W DC PSU in the Power Supply Bay 4 Verify that the DC power is turned off at the source CAUTION Always verify that the DC circuit is de energized before you connect the input cable to...

Страница 107: ...e bend radius and to avoid stress on the cables For example you should route the leftmost cable harness across the switch so that it exits through the right side of the grate Route the rightmost cable...

Страница 108: ...nt of the DC PSU by pressing down the catch see Figure 66 and pulling out the cable Figure 66 DC Cable Connector on the 1200 W DC PSU WARNING Always be sure that the 1200 W DC PSU does not have the in...

Страница 109: ...rd on page 121 Initial Management Access on page 122 NOTE Read the information in this chapter thoroughly before you attempt to install or remove an 8800 series MSM or I O module CAUTION Do not attemp...

Страница 110: ...chassis that has a manufacturing part number of 800129 00 revision 10 or earlier Most of these chassis models are labeled Aspen instead of BlackDiamond To verify the part number and revision use the...

Страница 111: ...ices or other modular accessories use an ESD preventive wrist strap to reduce the risk of electronic damage to the equipment Transport PC boards only in electrostatic packaging Always place PC boards...

Страница 112: ...e you prevent damage to the module that might be caused by sliding the module on the ESD surface Store the module packaging for future use CAUTION To prevent ESD damage hold the module by the metal ra...

Страница 113: ...lockwise and completely down When the screw is fully tightened the yellow band around the captive screw is completely hidden CAUTION Be careful to avoid over torquing and stripping the screw heads If...

Страница 114: ...O module 4 Press the cable connectors into their mating connectors on the switch or I O module until the cable connector is firmly seated 5 Repeat steps 1 through 4 for the remaining cables on this or...

Страница 115: ...module front panel as you use the other hand to pull back evenly on the latch Figure 73 Figure 73 Disconnecting a cable from a 10G4Ca port 2 Make sure the latch is pulled into the fully disengaged po...

Страница 116: ...and Verifying the Module Installation After you install a module verify that it is working correctly by checking the LEDs on the front panel of the module Table 21 shows normal LED operation for corre...

Страница 117: ...d module 1 Attach the ESD preventive wrist strap to your bare wrist If it is not already connected connect the metal end to the ground receptacle at the top left corner of the chassis 2 Unlock the mod...

Страница 118: ...ll a replacement module follow the installation procedure starting on page 111 NOTE Leave the ESD preventive wrist strap permanently connected to the chassis so that it is always available when you ne...

Страница 119: ...ver to tighten the captive screws at each end of the blank front panel NOTE Tighten the screws of each installed blank front panel before inserting additional modules or blank front panels Otherwise y...

Страница 120: ...rom the front of the BlackDiamond switch see Figure 78 Figure 78 Removing a Blank Front Panel from a BlackDiamond 8800 series Switch 4 Install an I O module or MSM in the open slot as described in Ins...

Страница 121: ...rom the slot 5 Carefully push the card until it is seated into the slot The card should be fully inserted or seated inside the slot 6 To verify that the card is fully seated use the show memorycard co...

Страница 122: ...om your local supplier or you can make your own To ensure the electromagnetic compatibility of the unit use only shielded serial cables For information about the DB 9 console plug connector see Connec...

Страница 123: ...see the ExtremeXOS Concepts Guide 6 Assign an IP address and subnetwork mask for VLAN default by typing configure vlan default ipaddress 123 45 67 8 255 255 255 0 Your changes take effect immediately...

Страница 124: ...Installing Modules and Establishing Initial Management Access BlackDiamond 8800 Series Switches Hardware Installation Guide 124...

Страница 125: ...3 Installing BlackDiamond Switch Accessories...

Страница 126: ......

Страница 127: ...ds PoE functionality to the ports on a G48Tc G48Te2 or 8500 G48T e I O module You must remove the I O module from the BlackDiamond 8800 series switch before you install the S POE card You need the fol...

Страница 128: ...8T e I O Module 4 Remove the S POE card from its anti static packaging 5 Align the S POE card with the connectors on the I O module see Figure 82 Following the sequence indicated in Figure 82 carefull...

Страница 129: ...is 2 Remove the I O module from the BlackDiamond 8800 series chassis as described in Removing a BlackDiamond 8000 Series Module on page 117 3 Loosen the spring loaded captive retaining screws on the S...

Страница 130: ...re not hot pluggable You must administratively disable the module and remove it from the switch before you install the option card To install an option card in an MSM 1 Attach the ESD preventive wrist...

Страница 131: ...rd align and finger tighten the captive retaining screws to secure the card in place Figure 85 Figure 85 Securing the Option Card 8 Re install the MSM following the instructions in Installing a BlackD...

Страница 132: ...hey pop up see Figure 86 4 At the edge of the module rotate the hot swap prevention latch up and hold it out of the way Figure 86 Removing an Option Card 5 Using the handle on the option card pull str...

Страница 133: ...the switch is disconnected by removing the wall plug from the electrical outlet Always be sure that all plugs and electrical outlets are easily accessible BlackDiamond 8810 AC Power Cord Retainer Conn...

Страница 134: ...AC Power Cord to the BlackDiamond 8810 Switch 4 Make sure that each AC power cord is firmly plugged into the power outlet as shown in Figure 89 Figure 89 AC Power Cord Plugged into the BlackDiamond 88...

Страница 135: ...nnect a BlackDiamond 8810 AC power cord 1 Attach the ESD preventive wrist strap to your bare wrist and connect the metal end to the ground receptacle on the top left corner of the switch chassis 2 Dis...

Страница 136: ...er Cord Retainer To install the BlackDiamond 8806 AC power cord retainer 1 Attach the ESD preventive wrist strap to your wrist and connect the metal end to the ground receptacle on the top left corner...

Страница 137: ...ghten the captive screw at each end of the retainer Figure 94 Securing the BlackDiamond 8806 AC Power Cord Retainer 5 Starting from the left lay the first four power cords into the retainer see Figure...

Страница 138: ...ond 8806 AC power cord retainer 1 Attach the ESD preventive wrist strap to your wrist and connect the metal end to the ground receptacle on the top left corner of the switch front panel 2 Using a 2 Ph...

Страница 139: ...Required Tools You need a 2 Phillips screwdriver to attach the power cord management bracket to the switch After the power cord management bracket is installed you do not need any tools to attach the...

Страница 140: ...tors on the switch 3 Attach the AC power cord retainer to the switch a Place the retainer against the front of the switch as shown in Figure 97 Make sure that the retainer engages all the power cord c...

Страница 141: ...tabs click into place Figure 99 Figure 99 Latching the PSU Cover Removing the BlackDiamond 8806 PSU Cover To remove the PSU cover 1 Press down on the latching tab at each side of the top 2 With the la...

Страница 142: ...anagement bracket with captive retaining screws Figure 100 PSU Cover Kit Installing the BlackDiamond 8810 PSU Cover To install the PSU cover 1 If necessary remove the installed AC cord retainer 2 Make...

Страница 143: ...tion Guide 143 Figure 101 Attaching the AC Cord Retainer 4 Set the feet on the base of the cover into the square openings on the top of the AC cord retainer Figure 102 Figure 102 Setting the PSU Cover...

Страница 144: ...e latching tabs click into place Figure 103 Figure 103 Latching the PSU Cover Removing the BlackDiamond 8810 PSU Cover To remove the PSU cover 1 Press down on the latching tab at each side of the top...

Страница 145: ...to manage multiple cable bundles The cable management accessories keep cables collected in one place rather than allowing them to hang freely If you must remove a module from the chassis for replacem...

Страница 146: ...es with 6 on each side Connect cable holders end to end as needed to accommodate the number of cables you need to organize To connect the cable holders 1 Hold two cable holders as shown in Figure 105...

Страница 147: ...Connect as many cable holders together as you need to manage your cable bundles 4 To disconnect the holders grasp one in each hand firmly and carefully pull them apart Connecting Cable Clips To connec...

Страница 148: ...148 3 Press the clips together until l the connectors lock into place see Figure 108 Figure 108 Cable Clip Chain 4 Connect as many cable clips together as you need to manage your cable bundles 5 To di...

Страница 149: ...BlackDiamond 8800 Series Switches Hardware Installation Guide 149 4 BlackDiamond Maintenance Procedures...

Страница 150: ...BlackDiamond 8800 Series Switches Hardware Installation Guide 150...

Страница 151: ...e front of the switch NOTE To avoid long periods of operation without forced air cooling make sure you have the replacement fan tray ready before you start the replacement procedure Pre Installation R...

Страница 152: ...f way out from the fan tray slot This action disconnects the fan tray from the switch power Wait for the fan blades to stop turning before continuing with this procedure WARNING Be sure that all fan b...

Страница 153: ...0 series switch 1 Attach the ESD preventive wrist strap to your bare wrist and connect the metal end to the ground receptacle on the top left corner of the switch 2 Support the bottom of the fan tray...

Страница 154: ...es switch has two PSU fan controllers behind an access panel on the rear of the switch chassis NOTE If your system is running ExtremeXOS version 11 2 1 3 or later you can hot swap the PSU fan controll...

Страница 155: ...and connect the metal end to the ground receptacle on the front top left corner of the switch 2 Locate the eight captive screws on the PSU fan controller access cover at the back of the BlackDiamond 8...

Страница 156: ...llips screwdriver loosen all eight captive screws on the PSU fan controller access cover 4 Pull the access cover away from the back of the switch The PSU fan controllers are visible in the controller...

Страница 157: ...eptacle on the front top left corner of the switch 2 Align the guide pins in the empty controller recess with the holes on the replacement PSU fan controller 3 Push the replacement PSU fan controller...

Страница 158: ...Replacing BlackDiamond 8800 Series Chassis Components BlackDiamond 8800 Series Switches Hardware Installation Guide 158...

Страница 159: ...ation CAUTION Correct lifting procedures for a BlackDiamond 8800 series chassis require two or more people Only trained service personnel should perform service to Extreme Networks switches and their...

Страница 160: ...end to the ground receptacle on the chassis front panel 2 Remove all modules and power supplies from the chassis Follow correct Extreme Networks procedures for removing components 3 Using four mountin...

Страница 161: ...BlackDiamond 8800 Series Switches Hardware Installation Guide 161 Figure 116 Correct Method for Lifting the BlackDiamond 8810 Chassis ASP017A...

Страница 162: ...ver the BlackDiamond 8810 chassis 10 Insert the clip locks see Figure 118 a Place your thumb and index finger inside the clip lock to grasp the prongs b Squeeze the prongs inward applying equal pressu...

Страница 163: ...chassis see Figure 119 Figure 119 Packing Foam in the BlackDiamond 8810 Shipping Carton 12 Close the top flaps on the shipping carton and seal them with packing tape 13 Secure the BlackDiamond 8810 sh...

Страница 164: ...the equipment rack immediately below the chassis 4 Remove the eight rack mounting screws that secure the chassis to the equipment rack 5 On each side of the chassis place one hand in the empty power s...

Страница 165: ...the prongs inward applying equal pressure on each side c Push the prongs inward until the clip lock is secured onto the carton Repeat these steps to insert each of the remaining clip locks CAUTION Pr...

Страница 166: ...h packing tape 12 Secure the shipping carton with nylon straps see Figure 125 NOTE Nylon straps are optional but are recommended by Extreme Networks for extra security during shipment The installation...

Страница 167: ...5 Appendices...

Страница 168: ......

Страница 169: ...Sicherheitshinweise on page 176 Safety information in German Considerations Before Installing Consider the following items before installing equipment The system is designed to operate in a typical en...

Страница 170: ...able power supply into the bay do not use excessive force If multiple power supplies are used in a switch connect each power supply to a different independent power source If a single power source fai...

Страница 171: ...cedure Disconnect all power cords before working near power supplies unless otherwise instructed by a product specific maintenance procedure When you handle modules optic devices power supplies or oth...

Страница 172: ...table for connection to intrabuilding or unexposed wiring or cabling only The intra building port s of the equipment or sub assembly MUST NOT be metallically connected to interfaces that connect to th...

Страница 173: ...country of installation For cords up to 6 feet 2 m long the wire size must be 18 AWG 75 mm2 minimum over 6 feet the minimum wire size is 16 AWG 1 0 mm2 Black Diamond SSI DC PSU Model 60021 The wire mu...

Страница 174: ...be replaced by qualified Extreme Service personnel only Contact your Extreme Service personnel for product replacement Do not attempt to replace the battery If these instructions are disregarded and r...

Страница 175: ...ng regulatory requirements Class 1 Laser Product EN60825 1 A2 2001 or later European laser standard FCC 21 CFR Chapter 1 Subchapter J in accordance with FDA CDRH requirements Application of CE Mark in...

Страница 176: ...Sonnenlicht Ausreichender Abstand zu Quellen die Ersch tterungen oder Schl ge St e hervorrufen k nnen Isolierung von starken elektromagnetischen Feldern wie sie durch Elektroger te erzeugt werden Sic...

Страница 177: ...rwenden um das System vor einer vor bergehenden Zu oder Abnahme der elektrischen Leistung zu sch tzen Bei laufendem Betrieb austauschbare Netzteile Das Netzteil vorsichtig nicht mit Kraft in das Aufna...

Страница 178: ...g der Ger te durch elektrostatische Entladungen zu verringern Das Armband zum Schutz elektrostatisch gef hrdeter Bauteile ESB grunds tzlich an der Grundplatte befestigt lassen damit es beim Umgang mit...

Страница 179: ...n Vorschriften Ihres Landes entspricht Erkundigen Sie sich ber die rtlichen Vorschriften f r Elektroinstallationen und fragen Sie bei den zust ndigen Aufsichtsbeh rden nach den Anforderungen an Stromk...

Страница 180: ...uf die Enden eines Faserkabels schauen wenn diese eingeschaltet sind Bei offenen Anschl ssen kann es zu unsichtbarer Laserstrahlung kommen Direkter Augenkontakt mit dem Strahl ist zu vermeiden Ein opt...

Страница 181: ...ht empty 79 lb 35 8 kg Weight fully loaded 196 lb 88 9 kg BlackDiamond 8810 fan tray Weight 6 75 lb 3 06 kg Minimum fan speed 500 RPM Maximum fan speed 6000 RPM Power supply Weight 7 lb 3 2 kg BlackDi...

Страница 182: ...se standards are module specific and may not apply to every module in the series IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX 100BASE FX IEEE 802 3z 1000BASE X IEEE 802 3ab 1000BASE T IEEE 802 3ac VLAN...

Страница 183: ...ight empty 63 75 lb 29 0 kg Weight fully loaded 153 lb 69 5 kg BlackDiamond 8806 fan tray Weight 4 75 lb 2 2 kg Minimum fan speed 500 RPM Maximum fan speed 6000 RPM BlackDiamond 8806 power supply Weig...

Страница 184: ...NZS 3548 ACA Australia Emissions CNS 13438 1997 Class A BSMI Taiwan MIC Mark EMC Approval North Korea Telecom Standards ETSI EN 300 386 2001 EMC Telecommunications ETSI EN 300 019 Environmental for Te...

Страница 185: ...SO 7779 High 73 dBA per ISO 7779 Declared sound power Normal 7 2 belsA per ISO 7779 ISO 9296 High 7 6 belsA per ISO 7779 ISO 9296 Sound pressure in accordance with NEBS GR 63 Issue 2 Bystander sound p...

Страница 186: ...341 BTU G48Xc Weight 7 55 lb 3 42 kg Power 125 W Heat Dissipation 427 BTU G48Te Weight 6 75 lb 3 06 kg Power 120 W Heat Dissipation 409 BTU G48Pe Weight 6 75 lb 3 06 kg Power 120 W Heat Dissipation 4...

Страница 187: ...es Hardware Installation Guide 187 S POE Card Dimensions 1 25 inches H by 14 31 inches W by 4 81 inches D 3 18 cm by 36 35 cm by 12 22 cm Weight 0 80 lb 0 36 kg Table 24 Specifications for BlackDiamon...

Страница 188: ...r 16 AWG 1 0 mm2 over 6 feet Operating conditions Operating temperature 0 C to 40 C Storage temperature 40 C to 70 C Operating humidity 10 to 90 relative humidity non condensing Operational shock 30 m...

Страница 189: ...ray cable copper stranded rated 90 C minimum Connector Molex connector PN 42816 0312 Connector pins Molex connector pins PN 42815 0032 Output DC output 48 V 24 A 12 V 4 A DC output power W 1200 W Oper...

Страница 190: ...le Figure 127 PC AT Serial Null modem Cable Pinouts Screen TxD RxD Ground RTS CTS DSR DCD DTR Cable connector 9 pin female Switch Cable connector 25 pin male female 25pin PC Terminal Screen RxD TxD Gr...

Страница 191: ...Series Switches Hardware Installation Guide 191 Figure 128 shows the port assignments for the MRJ21 connector Figure 128 Port to Pin Assignments in the MRJ21 Connector BD_232 Port 1 Port 3 Port 5 Por...

Страница 192: ...Technical Specifications BlackDiamond 8800 Series Switches Hardware Installation Guide 192...

Страница 193: ...LEDs 51 8900 G48X xl I O module features 50 LEDs 51 8900 G96T c I O module features 46 LEDs 51 8900 MSM128 module front panel 23 LEDs 24 A A button MSM 23 AC power cord retainer BlackDiamond 8806 swi...

Страница 194: ...bend radius fiber optic 76 UTP 75 category 5 75 fiber optic 76 for 8900 G96T c module 74 installing 75 slack 75 types and distances 73 cable clips 147 cable connections making 114 cable holder 146 cab...

Страница 195: ...es 70 securing 71 service access 71 space requirements 71 ESD discharge from cable 75 system protection 69 ESD preventive wrist strap 69 external compact flash slot 21 external memory card installing...

Страница 196: ...fications 185 verifying installation 116 identification records cable 72 IEEE 802 3 media access standards 182 184 indicators shipping 85 industry standards 80 initial switch login 122 inline power I...

Страница 197: ...em cable 190 PC AT serial null modem cable 190 plenum rated cable 75 PoE daughter card 127 module 31 port LEDs 52 PoE devices power requirements 78 ports console 23 console port settings 122 LEDs 51 m...

Страница 198: ...d 26 I O module compatibility 37 44 installation 127 weight 187 standards cabling 72 80 commercial building 80 grounding 80 rack 70 storage conditions 182 185 support bracket 90 switch configuration s...

Страница 199: ...75 RF interference 77 W warning state on shipping indicators 85 weight chassis components 183 modules 185 white state on shipping indicators 85 wiring closet airflow requirements 68 electrostatic dis...

Страница 200: ...Index BlackDiamond 8800 Series Switches Hardware Installation Guide 200...

Отзывы: