Display
ATTE
A new ignition is attempted when the stove
has just been switched off (normal switch-off
or caused by an alarm).
When the stove switches off (normal or caused by an
alarm) it is necessary to wait until complete fumes motor
switch off and then clean the brazier.
The stove can only be re-ignited when these operations
have been performed.
STBY
Stove off waiting for re-ignition.
In this mode the machine can be switched on/off by
means of an additional thermostat.
HOFF
The temperature of the water has exceeded
the set threshold by more than 5°C.
Check the correct functioning of the hydraulic plant.
On lowering of the water temperature (5° below the set
threshold) the machine will re-start in automatic mode.
To exclude any stove re-ignition just hold button 1 down
for 3 seconds, taking the stove to
OFF
.
RAF / BLAC
OUT
No current on the main power supply.
After the complete switch-off cycle the stove will re-
ignite automatically.
PUL
Automatic pot cleaning is in progress.
The automatic pot cleaning is performed at pre-
established intervals of continued working.
The automatic cleaning does not start if the stove is in
1st power.
Attention! It is however recommended to manually
clean the brazier every day.