ASSEMBLY AND INSTALLATION INSTRUCTIONS
16
Chapter 5
ASSEMBLY AND INSTALLATION INSTRUCTIONS
The installation must be in compliance with:
UNI 10683 (2005) heat generators fed with wood and other solid fuels: installation.
The chimneys have to be in compliance with:
UNI 9731 (1990) chimneys: classifi cation based on thermal resistance.
EN 13384-1 (2006) chimneys thermal and fl uid-dynamics calculation method.
UNI 7129 point 4.3.3 Fire Department dispositions, local rules and prescriptions.
UNI 1443 (2005) chimneys: general requisites.
UNI 1457 (2004) chimneys: terracotta and ceramic inside pipes.
GLOSSARY
CLOSED HEARTH APPLIANCE
Heat generator which opening is only allowed through the loading of the fuel during use.
BIOMASS
Biological material, excluding the material incorporated in geological formation and transformed in fossil.
BIOFUEL
Fuel produced directly or indirectly by biomass.
CHIMNEY
Vertical pipe with the aim to collect and expel, at a convenient height from the ground, the fuel products
coming from only one appliance.
SMOKE CHANNEL OR CONNECTION
Pipe or connecting element between heat generator appliance and chimney to evacuate fuel products.
INSULATION
Together of devices and materials used to prevent the transmission of heat through a wall which separates
rooms with diff erent temperature.
CHIMNEY CAP
Device positioned at chimney peak to ease the dispersion of fuel products in the atmosphere.
CONDENSATION
Liquid products which form when the fuel gas temperature is lower or equal to the water dew point.
HEAT GENERATORS
Appliance which allows to produce thermal energy (heat) through the rapid transformation, through
combustion, of the chemical energy of the same fuel.
GATE VALVE
Mechanism to amend the fuel gas dynamic resistance.
Содержание DUCHESSA IDRO
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 15: ...SAFETY DEVICES 15 Chapter 4 Door micro switch Rearm of the tank bulb 85 C Rearm water bulb 100 C ...