PRODUCT FUNCTIONALITY
28
Chapter 7
WATER TEMPERATURE ADJUSTMENT
The appliance can control the water temperature through a digital probe which automatically adjusts the
machine functioning when nearing the desired temperature.
When the stove is started and has entered normal functioning mode, display D1 will shows the water
temperature.
Adjust the desired water temperature using keys 2 and 3. During adjustment,
“SET”
in fl ashing mode
and the temperature to be set will appear on display D1 (the value has max travel from 60 to 80°C)
whereas the functioning power will appear on display D2.
When the desired temperature has been adjusted, let
“SET”
disappear from the display.
Adjust the desired functioning power using buttons 4 and 5.
When nearing the desired water temperature, the product will automatically modulate fuelling.
When the displayed water temperature exceeds by approx. 5° that set, the machine will go in H OFF,
automatically switching itself off .
The pump continuous to work during H OFF phase.
The machine will switch on again when the water temperature inside the stove decreases by approx.
5° from the pre-set.
Check the content of the feed-box in order to prevent the fi re going out due to the lack of fuel.
N.B. It is recommended to adjust the stove at maximum power to speed up the water heating process;
the stove will automatically slow down when nearing the set temperature.
Functioning summary example:
1st Ignition
2nd Start-up
3rd Work
H OFF
(reached water set)
START (re-ignition)
variable times
max 15
count-down
Set by customer =
70° C
75
65
N.B. The automatic switch off and start-up temperatures are subject to thermal inertia and delays
controlled by the internal program, therefore a slight tolerance must be taken into account.
WORK
When ignition has taken place, the user can adjust the heating power using buttons 4 and 5. By pressing
button 4 the heat power is decreased and therefore the consumption of pellets, vice versa by pressing 5
the heating power is increased and as a consequence pellet consumption.
ATTENTION!
The lid of the pellet container must always be closed. It must only be opened during the fuel
1.
loading phase.
The bags of pellets must be kept at least 1.5 metres from the stove.
2.
It is recommended that the feed-box is always half full.
3.
Make sure the appliance is off before fi lling the pellet tank.
4.
Содержание DUCHESSA IDRO