background image

1

January 8, 2019

7082-154E

NOTICE: DO NOT DISCARD THIS MANUAL

R

TREKKER INSERT PELLET 

APPLIANCE

MODEL(S):

TREKKERI-MBK

TREKKERI-CSB

TREKKERI-PMH

Owner’s Manual

Operation & Care

INSTALLER: Leave this manual with party responsible for use and operation. 

OWNER: Retain this manual for future reference. 

Contact your dealer with questions regarding installation, operation or service.

Installation and service of this appliance should be performed by 

qualified personnel. Hearth & Home Technologies recommends 

HHT Factory Trained or NFI certified professionals.

Tested and approved for wood pellets only. Burning of 

any other type of fuel voids your warranty. 

CAUTION

CAUTION

Check building codes prior to installation.

•  Installation MUST comply with local, regional, state 

and national codes and regulations.

• 

Consult local building, fire officials or authorities 

having jurisdiction about restrictions, installation 

inspection, and permits.

WARNING

If the information in these instructions is 

not followed exactly, a fire could result 

causing property damage, personal 

injury, or death.

• 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

• 

Do not over fire - If appliance or chimney connector 

glows, you are over firing. Over firing will void your 

warranty.

•  Comply with all minimum clearances to combustibles 

as specified. Failure to comply may cause house fire.

HOT SURFACES!

Glass and other surfaces are hot during 

operation AND cool down. Hot glass will 

cause burns.

WARNING

•  Do not touch glass until it is cooled

•  NEVER allow children to touch glass

•  Keep children away

• 

CAREFULLY SUPERVISE children in same room as 

fireplace.

•  Alert children and adults to hazards of high 

temperatures

•  High temperatures may ignite clothing or other 

flammable materials.

•  Keep clothing, furniture, draperies and other 

flammable materials away.

NOTE

To obtain a French translation of this manual, please contact 

your dealer or visit 

www.quadrafire.com

Pour obtenir une traduction française de ce manuel, s’il vous 

plaît contacter votre revendeur ou visitez 

www.quadrafire.com

Содержание TREKKER INSERT series

Страница 1: ...ation in these instructions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicin...

Страница 2: ...ent 50 775 Btu s hr Puissance lectrique 115 VAC 60 Hz D but 2 9 Amps Courir 2 45 Amps loignez le fil lectrique de l appareil Ne pas faire passer le fil lectrique au dessus ou en dessous de l appareil...

Страница 3: ...ntenance and Service 14 A Proper Shutdown Procedure 14 B Quick Reference Maintenance Chart 14 C General Maintenance and Cleaning 15 D Soot or Creosote Fire Awareness 18 E High Ash Fuel Content Mainten...

Страница 4: ...ronic components and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free ceramic f...

Страница 5: ...nging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warranted...

Страница 6: ...o water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS WAR...

Страница 7: ...Plug in the ap pliance exhaust blower will run for about 45 seconds wait for it to stop before moving to manual feed 65 72 HEATING 5 From the OFF home screen press and hold the outer ring for 3 second...

Страница 8: ...ood Pellets Weighted average LHV efficiency using data collected during EPA emissions test Weighted average HHV efficiency using data collected during EPA emissions test A range of BTU outputs based o...

Страница 9: ...gov G California Prop65 F Sleeping Room When installed in a sleeping room it is recommended that 3ft of vertical be installed prior to horizontally exiting the room and a smoke CO alarm be installed...

Страница 10: ...content That is why some fuels produce more clinkers than others Moisture Always burn dry fuel Burning fuel with high moisture content takes heat from the fuel and tends to cool the appliance robbing...

Страница 11: ...opened This startup cycle continues until the unit senses ignition by a rise in the exhaust temperature or the unit times out Following the ignition cycle the unit continues to feed pellets to build u...

Страница 12: ...adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away Figure 12 2 8 30 AM TUNIN...

Страница 13: ...llers becoming dirty over time See maintenance and service section for maintaining and servicing What is the metal object with the bend in it that came inside the plastic bag It is a clean out tool us...

Страница 14: ...e for your appliance Visit www quadrafire com owner resources to view basic troubleshooting FAQs use care videos We recommend annual service by a qualified dealer Cleaning or Inspection Frequency Dail...

Страница 15: ...sh pan will have to be cleaned out more often than ash Ash Disposal Ashes should be placed in a steel container with a tight fitting lid The container of ashes should be moved outdoors immediately and...

Страница 16: ...he heat exchanger fins It is critical that the 2 exhaust exits at the back of the firebox floor left and right be thoroughly cleaned Figure 16 2 There are several ways this can be done Use the crevice...

Страница 17: ...d This can result in nuisance shut downs and mis starts Empty the hopper of any remaining pellets Vacuum the hopper and feed tube Figure 17 1 Ash Dump Lever WARNING Risk of fire Do NOT store fuel Clos...

Страница 18: ...me soot formation which will collect in the exhaust venting system NOTE Ash will build up more quickly in the horizontal venting sections 13 Preparing Firebox for Non Burn Season Frequency See chart o...

Страница 19: ...down The bottom of the latch will fall forward off of the post Lift the baffle up and then out toward you Figure 19 2 5 To replace the baffle place the 2 locating ears behind the bottom edge and tilt...

Страница 20: ...remove the motor and impeller 4 Disconnect the wire from the control board connection and hall effect switch housing 5 Using an 7mm socket wrench or nut driver loosen the nuts securing the motor and...

Страница 21: ...t functioning Check hopper switch operation Check hopper switch wires for integrity Check hopper lid on correctly Check hopper lid magnet is installed Safety snap disc is tripped not functioning Check...

Страница 22: ...Secure the exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Defective probe Replace probe Control board is defective Replace control board Convection Blower fails to shu...

Страница 23: ...off Excessive fuel spilling over the fire pot and or excessive flame Dirty Appliance Clean unit including the fire pot exhaust path and venting system Feed Motor locked on Follow corrective action for...

Страница 24: ...niter lead connections or replace igniter Exhaust probe not properly installed Secure exhaust probe to exhaust blower housing keeping its wire away from hot surfaces Igniter chamber plugged with debri...

Страница 25: ...through the venting system 2 Control Board The control board is located on the right side of appliance It controls the functioning of the appliance and communicates with the user interface through the...

Страница 26: ...26 January 8 2019 7082 154E TREKKER INSERT B Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 27: ...27 January 8 2019 7082 154E TREKKER INSERT Date of Service Performed By Description of Service...

Страница 28: ...KKER INSERT Beginning Manufacturing Date June 2018 Ending Manufacturing Date Active Pellet Insert TREKKERI CSB TREKKERI MBK TREKKERI PMH Part number list on following pages 01 19 1 2 3 4 5 6 7 8 9 10...

Страница 29: ...07CSB Gasket Extruded Field Cut to Size 10 FT 7000 320 10 2 Top Hinge Assembly SRV7036 006 3 Top Matte Black 7036 101MBK Porcelain Mahogany 7036 101PMH Sienna Bronze 7036 101CSB 4 Catch Clip 7036 146...

Страница 30: ...Gasket Channel 3 Mm X 32 Field Cut to Size 10 Ft 7000 377 10 Y 17 Ash Pan Door SRV7034 133 18 Ash Pan Assembly SRV7034 069 Twin Ball catch SRV7000 532 Y 19 Intake Shield 7034 224 Y 20 Firepot Riser As...

Страница 31: ...29 Combustion Blower SRV7080 106 Y Gasket Blower Combustion Between Housing Stove SRV7080 117 Y Gasket Motor Blower Combustion Between Housing Motor SRV7080 107 Y Gasket Exhaust SRV7034 109 30 Flue C...

Страница 32: ...Flue Adapter Required if TPVNT 4 is removed LKADP Surround Std Panel For Cast Trim SP MTVS CST Component Pack 7036 041 Surround Std Panel w Gold Trim No longer available SP MTVS GD Component Pack 7036...

Страница 33: ...Washer Sae Pkg of 25 227 0080 25 Y Washer FI 1 4 Black Pkg of 10 1202473 10 Pkg of 50 1202473PK Screw Hwh Ms 1 4 20 X 3 4 Ns Pkg of 25 220 0080 25 Y Nut Ser Flange Small 1 4 20 Pkg of 24 226 0130 24 Y...

Страница 34: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deal...

Отзывы: